Catalog excerpts
AKS16 Absolute Magnetic Sensing Head AKS16 can be used for linear measurements up to 256 mm in length and rotary measurements - radial and axial - up to 79 mm in diameter. The encoder provides both BISS-C or SSI as output plus incremental signal output in parallel. With a resolution of 18-20 bits this hollow shaft encoder surpasses typical shaft end applications many times over. With dimensions of 24.2 mm or 28 mm in length, 16 mm width and a height of 6.6 mm (Molex version) or 3.4 mm (FFC version) the AKS16 is very compact. Absolute Measuring Rotary Linear Applications Features and Benefits • 18 to 20 Bit absolute resolution • 18 Bit incremental resolution AKS16 Rev 2.6 (2020/08/31) • Small dimensions for space-saving implementation • Resistant against contamination, vibrations, temperature, fIuctuations, humidity • No wear from usage • Corresponding scales in various diameters and lengths
Open the catalog to page 1Features absolute resolution * commutation signal for 1 to 16 pole pairs (UVW) resolution 18 Bit: up to 24,000 rpm rotation speed resolution 19 Bit: up to 12,000 rpm resolution 20 Bit: up to 6,000 rpm pole pitch sensing head optimal distance:magnetic target supply voltage maximum output load energy consumption (without load) operating temperature storage temperature protection class 4 and 262144 in steps of four based on pole pitch pole pitch maximum torsional moment of threaded inserts * resolution depends on the diameter/length of the scale Output Signals ABZ signals / inverted signals...
Open the catalog to page 2Signals BISS signal amplitude (without load) protocol multiturn clock (MA+, MA-) data (SLO+, SLO-) RS422 (± 5 V) BISS-C BP3 encoder profile on special request; timeout (ttos) permissible clock period (tMAS) clock signal hi level duration (tMASh) clock signal lo level duration (tMASl) please contact our sales staff 150-380 ns 100 ns up to 2 * timeout 50 ns up to timeout 50 ns Timing Diagram BISS Signals SSI signal amplitude (without load) multiturn clock (MA+, MA-) data (SLO+, SLO-) RS422 (± 5 V) in special request; timeout (ttos) permissible clock period (tMAS) clock signal hi level...
Open the catalog to page 3Orientation Options for 1.28, 1.50 and 2.00 mm (1.50 mm shown for reference) orientation option 1 (parallel) orientation option 2 (perpendicular) linear scale rotary scale radial rotary scale axial Pin Assignment output signals depending on selected interface incremental (D-parameter) DIR SLOSLO+ VV+ MAMA+ DIR /STEP STEP Molex 501568-1207; 12 pin male connector; mating cycles: 30 FFC (12 pin, 0.5 mm pitch); mating cycles: 20
Open the catalog to page 4orientation option 2 (perpendicular) orientation option 1 (parallel) Master Track Nonius Track Master Track Nonius Track *) Installation marks for scale widths 6 mm and 10 mm
Open the catalog to page 5orientation option 2 (perpendicular) orientation option 1 (parallel) 8 9,8 ±0,1 Master Track Nonius Track Nonius Track Master Track
Open the catalog to page 6Nonius Track Master Track Track Width orientation option 2 (perpendicular) orientation option 1 (parallel) *) Installation marks for scale widths 10 mm and 12mm
Open the catalog to page 7orientation option 2 (perpendicular) orientation option 1 (parallel) 8 10 ±0,1 Master Track Nonius Track Nonius Track Master Track Track Width Please note: dimensions not shown correspond to those specified for the Molex version Each unit needs to be calibrated in final assembly with a nonius scale. For the calibration, the scale needs to be moved over the whole measuring length. For calibration, the programming unit including cables and the BOGEN software will be needed. A PC is required for the calibration. The use of non BOGEN approved software may result in lesser performance or...
Open the catalog to page 8Installation Tolerances for 1.28, 1.50 and 2.00 mm (1.50 mm shown for reference) Linear Scale Orientation Option 2 (Perpendicular) Linear Scale Orientation Option 1 (Parallel) Nonius Track Master Track Nonius Track Master Track Rotary Radial Scale Orientation Option 2 (Perpendicular) Rotary Radial Scale Orientation Option 1 (Parallel) Nonius Track Master Track Master Track Rotary Axial Scale Orientation Option 1 (Parallel) Rotary Axial Scale Orientation Option 2 (Perpendicular) Master Track Nonius Track Master Track Nonius Track
Open the catalog to page 9Assembly Values and Tolerances for 1.28 mm pole pitch: 0.4 mm ± 0.05 A [mm] for 1.50 mm pole pitch: 0.5 mm ± 0.05 for 2.00 mm pole pitch: 0.6 mm ± 0.05 note: for tolerance purposes the bracket for mounting the AKS16 should have adjustment options; maximum eccentricity of rotary scale must be < 0.06 mm; the installation tolerance is the same for both orientation options Order Code AKS16 - O - P - C orientation option explanation (1) Parallel Perpendicular 1.28 mm 1.50 mm 2.00 mm Molex 12 pin FFC 12 pin, 0.5 mm pitch, length 142 mm (2) AKS16 Magnetic Sensing Head, orientation option parallel,...
Open the catalog to page 10Required Accessories programming unit (55030)* for AKS16 with C1 connector *) includes programming adapter (52039), USB connector cable (53016), adapter cable Molex C1 (58276) and magnetic viewer **) includes programming adapter (52039), USB connector cable (53016), adapter PCB (55028) and magnetic viewer; please note: sensor is equipped with FFC cable, no additional adapter cable required Corresponding Linear and Rotary Magnetic Scales BOGEN offers a comprehensive scope of standard and tailor-made scales in a variety of sizes and accuracy classes. For more information on our standard...
Open the catalog to page 11All BOGEN Magnetics GmbH catalogs and technical brochures
-