COMPRESSED-AIR TREATMENT UNITS - CONDENSATE DRAINER
2Pages

{{requestButtons}}

Catalog excerpts

COMPRESSED-AIR TREATMENT UNITS - CONDENSATE DRAINER - 1

BOGE compressed-air treatment units BOGE condensate drainer Filter/Water separator (max. 16 bar) Compact modular design. Connections on both sides for other devices. Manual or automatic condensate drainage. Connection size Dimensions: Installed length Nominal flow rate at 6 bar inlet pressure (p1) and pressure drop ∆p = 1 bar Pressure relief valve with gauge (max. 25 bar) Compact modular design. Connections on both sides for other devices. Setting can be locked by pushing in the large handwheel. Connection size Dimensions: Installed length Width mm Height mm Nominal flow rate at 10 bar intake pressure (p1), 6 bar secondary pressure (p2) and pressure drop ∆p = 1 bar to DIN ISO 6953 Lubricator (max. 16 bar) Compact modular design. Integrated quantity compensation. Connections on both sides for other devices. Connection size Dimensions: Installed length Width mm Height mm Nominal flow rate at 6 bar intake pressure (p1) and pressure drop ∆p = 1 bar Combined filter/pressure relief valve with gauge (max. 16 bar) Compact modular design. Manual or automatic condensate drainage. Pressure relief valve with secondary venting. Setting can be locked by pushing in the large handwheel. Connection size Dimensions: Installed length Width mm Height mm Nominal flow rate at 10 bar inlet pressure (p1), 6 bar secondary pressure (p2) and pressure drop ∆p = 1 bar to DIN ISO 6953 Accessories: Fastening bracket (wall-mounting), coupling set, 30 micron filter set, 5 micron filter set, 30 micro

Open the catalog to page 1
COMPRESSED-AIR TREATMENT UNITS - CONDENSATE DRAINER - 2

§BOGE COMPRESSED AIR SYSTEMS BOGE Compressed Air Systems GmbH & Co. KG P O. Box 10 07 13 ■ 33507 Bielefeld, Germany Otto-Boge-StraBe 1-7 ■ 33739 Bielefeld, Germany phone +49 5206 601-0 fax +49 5206 601-200 info@boge.com ■ www.boge.com Pressure reducer With balanced single-seat valve (transmits no pressure fluctuations from the intake pressure side to the outlet pressure side) or with non-balanced single-seat valve (transmits pressure fluctuations from the intake pressure side to the outlet pressure side). Bekomat electronic level-controlled condensate drain NO COMPRESSED AIR LOSS Capacitive...

Open the catalog to page 2

All BOGE catalogs and technical brochures

  1. C- 2 SERIES

    7 Pages

  2. BOGE Filter

    2 Pages

  3. BOGE LPT 150

    4 Pages

  4. Po series

    8 Pages

  5. EO Series

    4 Pages

  6. DS-2 dryer

    2 Pages

  7. DASZ-P

    2 Pages

Archived catalogs

  1. BOGE PO Snow

    2 Pages

  2. FLEXPET BFPO

    2 Pages

  3. BOGE BLUEKAT

    4 Pages

  4. C4 - C15 DR

    2 Pages