Vent Silencer Overview
A vent silencer is designed to reduce high noise levels from high-pressure gas or steam expansion. It operates by using two noise reduction principles: a reactive section to attenuate low frequencies and absorption of high-frequency noise into sound-absorbing material. It also provides back pressure relief for system operation.

Typical Applications
  • Safety Valve (PSV)
  • Relief Valve (PRV)
  • Ejector
  • Start-up Valve
  • Snort-valve
  • Flash and Blow Down Tanks

Typical Installations
  • Combined Cycle
  • CHP Plants
  • Fossil Fuel Power Plants
  • Thermal Solar Plants
  • Nuclear Power Stations
  • Industrial and Oil & Gas Applications

Specifications
  • Hydraulic sizing based on flow rate, valve set pressure, and temperature.
  • Material specifications for various temperature ranges and corrosion allowance.
  • Noise guarantee details including point of measure and pipe noise interference.
  • Pipe connection options include butt weld and flanges.
  • Rain hoods impact noise guarantee and address snow and ice issues.

Standard Range
Noise reduction capabilities are categorized into Residential, Critical, Super Critical, Extreme, and Super Extreme, with specific flow rates and noise reduction levels.

Vent Silencer Dimensions
Dimensions and weights are provided for various categories, indicating the outer diameter and corresponding weight.

Product Referencing
Products are referenced by group, family, acoustic performance, measurement unit, silencer diameter, material, and inlet pipe diameter.

Vent Silencer Options
  • Connection options include standard butt weld and various flange classes.
  • Support options include standard bottom plate supports and additional options.
  • Stuffing box allows for pipe movements due to thermal expansion.
  • Rain hoods prevent rain entry and include a bottom drain.

Our Customers
Notable clients include Air Liquide, Thermax, Jacobs, Exxon, Total, Aramco, and many others.
See more

Catalog excerpts

Vent Silencers-1

Vent Silencers A complete range of products for high pressure systems

 Open the catalog to page 1
Vent Silencers-2

Vent Silencer Overview A vent silencer is a device intended to reduce the very high noise levels created when high pressure gas or steam is expanded to the atmosphere. This noise is produced by rapid turbulence of the vented gas jet and the release of energy from the compressed gas. Most of the noise occurs at the expansion across the valve and is emitted at the stack opening. The vent silencer can also provide back pressure relief for the system ensuring proper operation. There are two noise reduction principles used in a vent silencer. The first is a reactive section (diffuser) to attenuate...

 Open the catalog to page 2
Vent Silencers-3

Our Capabilities • Acoustic design and optimisation • 3D CAD model engineering • Static calculation • Pressure part calculation • Pressure part design check • Pressure Equipment Directive (PED) compliance • Quality inspection • Full technical documentation • Full supply-chai

 Open the catalog to page 3
Vent Silencers-5

Vent Silencer Specifications Hydraulic sizing • Flow rate, valve set pressure and temperature • Saturated or Superheated Steam • Other gases: oxygen, methane... Type of operation • Safety: intermittent operation • Control, start-up and blow down: regular or continuous operation Pressure Drop / Back Pressure • Valve integrity factor • Control and stabilisation of process condition Material Specification • From low temperature to high temperature • Corrosion allowance Noise Guarantee details • Point of measure • Pipe noise interference Pipe Connection • Butt weld • Flanges • Counters flanges /seals...

 Open the catalog to page 5
Vent Silencers-6

Standard Range Noise reduction dB(A) Special Available for higher noise reduction Super Extreme Super Critical

 Open the catalog to page 6
Vent Silencers-8

Connection (Standard supply: Butt weld) Connecting flanges • Standard: WN flanges Class 150# as per ASME B 16.5 • Options available for other classes and alternatives (e.g. slip-on) Support Standard supports are part of the bottom plate Other supports can be supplied as options Stuffing Box Allows pipe movements due to thermal expansion, avoiding nozzle loads • Standard radial movement is +/- 20mm • Standard axial movement up to 50mm • Pipe sealing is maintained Rain Hoods • Prevents rain entering the silencer • Bottom drain as standard

 Open the catalog to page 8
Vent Silencers-9

Our Customers Boet Stopson has provided vent silencers to some of the largest organisations around the world. Some of of past clients include: Air Liquide Thermax Jacobs Boccard Cegelec Cevital SPA CME Engineering Cockerill Mechanical Industrie Diamond Power APA Gasnet Foster Wheeler EDF Dresser Exxon Technip Chiyoda Total JGV Aramco Reliance ESB COFIVA QatarGaz SNC-Lavalin CTEP CNIM Alstom PraxAir