Overview: The Magnetic Basic Temperature Controller by BOE Therm is designed for use with pressurized water as the circulation medium, operating within a temperature range of 10 to 160°C. It features a magnetically joined pump to eliminate shaft seal issues and includes a stainless steel pressurized tank with a booster pump for constant pressure maintenance.
Specifications:
  • Temperature Range: 10 - 160°C
  • Maximum Tank Pressure: 7.0 bar
  • Included Tank Pressure: 12.2 bar
  • Circulating Medium: Water
  • Maximum Pump Capacity: 3,600 l/h
  • Maximum Pump Pressure: 5.6 bar
  • Pump Motor Capacity: 1.0 kW
  • Heating Capacity: 9 kW
  • Cooling Capacity at Δt = 120°C: 42 kW
  • Connection Load: 10 kW
  • Power Consumption at 400 V max.: 11.3 Amp
  • Noise Level: < 70 db A
  • Hose Connections: BSP 1/2”
  • Tank Volume: 6 liters
  • Dimensions (L/W/H): 650/265/650 mm
Key Features:
  • Automatic water level monitoring and fill-up
  • Components in contact with the medium are rust-resistant
  • Equipped with a microprocessor control, temperature sensor, and level sensor
  • Includes safety features such as a safety valve and solenoid valves for air, filling, and cooling
Options and Interfaces: The document lists various options and interfaces available for different models, including temperature ranges, circulating mediums, and industrial interfaces like Profibus, Canbus, and Devicenet. Additional features include auto cool down, auto refill, temperature deviation alarm, and remote control capabilities.
Graphical Data: The document includes pump capacity and cooling capacity curves, illustrating the relationship between tank temperature and cooling water temperature.
See more

Catalog excerpts

Magnetic-1

A THERMAL CARE COMPANY Magnetic basic Temperature Controller

 Open the catalog to page 1
Magnetic-2

Magnetic basic is operating with pressurized water as the circulation medium in the temperature range from 10 to 160°C. In addition, Magnetic is equipped with a pressurized tank in stainless steel and also with a booster pump ensuring a constant pressure. The unit is supplied with a default heating capacity from 4.5 to 9kW. The pump is magnetically joined, which means that possible problems with shaft seal are avoided. All components in contact with the medium are produced in materials that cannot rust. The control unit monitors the water level in the tank and ensures automatic fill-up.

 Open the catalog to page 2
Magnetic-3

Magnetic basic Specifications Temperature range: Tank pressure incl.: Circulating medium: Pump motor capacity: Heating capacity: Connection load: Noise level: Hose connections: Tank volume:

 Open the catalog to page 3
Magnetic-4

Pump capacity curve Cooling capacity curve Δ t = Tank temperature less cooling water temperature

 Open the catalog to page 4
Magnetic-5

From mould To mould Inlet, cooling water Outlet, cooling water Pump Tank Level sensor Temperature sensor Microprocessor control Heat exchanger Heating element Solenoid valve, air Solenoid valve, filling Solenoid valve, cooling Connection, remote sensor (option) Boosterpump Safety valve

 Open the catalog to page 5
Magnetic-7

A blend of people and possibilities One degree better - and a lot more...

 Open the catalog to page 7
Magnetic-8

ONE DEGREE BETTER - AND A LOT MORE... BOE THERM A/S · Industrivaenget 1 · DK-5610 Assens · Phone +45 6471 2375 Fax +45 6471 2303 · [email protected] · www.boe-therm.dk

 Open the catalog to page 8

All Boe-Therm A S catalogs and technical brochures

  1. Plastic belts

    3  Pages

  2. Z conveyors

    3  Pages

  3. TEMP 150

    8  Pages

  4. TEMP 90D

    8  Pages

  5. TEMP 95 VAC

    8  Pages

  6. multi temp

    2  Pages

  7. temp 300

    8  Pages

  8. temp 95

    8  Pages

  9. temp 350

    8  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.