1. Catalogs
  2. BODINE ELECTRIC COMPANY
  3. Permanent Magnet DC 2-Wire Reversible

Permanent Magnet DC 2-Wire Reversible

Permanent Magnet DC 2-Wire Reversible

Permanent Magnet DC 2-Wire Reversible

Product catalog summary
Specifications and Features
The document provides details about a Permanent Magnet DC 2-Wire Reversible Motor, Model 07410101 L. The direction of rotation is clockwise, and reversing the direction requires transposing the white and black leads. The motor is designed for universal horizontal mounting, and vertical mounting is not recommended without consulting the factory.

Warranty Information
Bodine Electric Company offers a limited warranty for 12 months from the purchase date or 18 months from the manufacture date, whichever comes first. The warranty covers defects in workmanship and materials under normal operating conditions. It does not cover commutator or brush wear, misuse, abuse, or unauthorized modifications.

Safety and Installation Guidelines
The document emphasizes the importance of following safety standards such as ANSI, NEMA, U.L., and CSA. It advises against using Bodine products in hazardous locations unless they are certified for such use. Proper grounding, thermal and overcurrent protection, and adherence to the National Electrical Code (NEC) are crucial for safe installation.

Maintenance and Use
Before servicing, disconnect the power source. Regular cleaning is necessary to prevent dust interference. Brush-type motors require periodic maintenance, and brushes should be inspected and replaced as needed. All Bodine products are lubricated for life and do not require re-lubrication.

Connection and Wiring
Follow the nameplate for voltage, frequency, and phase of the power supply. Ensure the motor is securely grounded to prevent injury. Wiring diagrams are available on the Bodine Electric website.

Additional Considerations
Motors with capacitors can develop more than nameplate voltage, requiring precautions. Mechanical locking devices should be used to hold loads in place if movement could cause injury. For motors driven by electronic controls, independent switches or relays should be used for safety interlocks.
See more

Catalog excerpts

Permanent Magnet DC 2-Wire Reversible-1

Tel: 1-800-7BODINE (U.S. only) Tel: 773-478-3515 Fax: 773-478-3232 E-mail: [email protected] Corporate Web: www.bodine-electric.com CONNECTION DIAGRAM 07410101 Permanent Magnet DC 2-Wire Reversible Green or Green-Yellow Tracer Direction of Rotation: Clockwise To reverse direction of rotation, transpose White & Black leads. BODINE LIMITED WARRANTY The Bodine Electric Company warrants all products manufactured by it to be free of defects in workmanship and materials when used under Normal Operating Conditions and when applied in accordance with nameplate specifications. This warranty shall be in effect for a period of twelve months from date of purchase or eighteen months from date of manufacture, whichever comes first. The Bodine Electric Company will, at its option, repair, replace, or refund the purchase price of any of its products, which has been found to be defective and is within the warranty period, provided that the product is shipped freight prepaid, with previous authorization, to Bodine Electric, or to the nearest Bodine Authorized Service Center. At its option, all return shipments are F.O.B. Bodine’s plant or Authorized Service Center. Bodine is not responsible for removal, installation, or any other incidental expenses incurred in shipping the product to or from Bodine. This warranty is in lieu of any other expressed or implied warranty-including (but not limited to) any implied warranties of merchantability and/or fitness for a particular use or purpose. Bodine’s liability under this warranty shall be solely limited to repair or replacement of the Bodine product within the warranty period and Bodine shall not be liable, under any circumstances, for any consequential, incidental or indirect damages or expenses associated with the warranted products. Commutators and/or brush wear and its associated effects are a normal occurrence and are not covered by this warranty unless otherwise agreed to by Bodine in writing. Any Bodine product, which is damaged due to misuse, abuse, negligence or has been modified or dismantled without the knowledge or written consent of Bodine, is not covered by this warranty. Motor/Gearmotor Serial No. _____________________ Purchase Date ____________ Installed By __________________ See Other Side for Safety, Installation, Use and Maintenance Information Printing Instructions per SMKDI-770-01

 Open the catalog to page 1
Permanent Magnet DC 2-Wire Reversible-2

Gearmotor/Motor Safety, Installation, Use, and Maintenance Information Thank you for selecting a gearmotor/motor from Bodine Electric Company. With your new drive unit you will find yourself enjoying the same high performance and trouble free operation that has been characteristic of Bodine products since 1905. Bodine Electric Company prides itself on the quality of design and manufacture of its products. Great care is taken in an attempt to provide products free of defects in workmanship, or materials. “The use of electric machines, like that of all other utilization of concentrated power, is...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry