OttFY MotioN. Instructions for Installation and OperationType WPM Filtered PWM Speed Controls for Permanent Magnet DC Brush Motors • Models 0790 & 0791, NEMA 1 enclosure SPECIFICATIONS Input Voltage_ Maximum Input Current, Continuous Output Voltage_ Ambient Temperature_ Maximum Output Current, Continuous Maximum Output Current, Peak Speed Regulation Acceleration/Deceleration Time Means for Speed Adjustment Means for Drive Inhibit_ _obtainable with most motors _switch closure green power LED, red current limit LED * Thermal rating only. Actual max. continuous output current is 1.25 Amps. INSTALLATION WARNING: This control should only be installed by a qualified person familiar with its operation and associated hazards. The National Electrical Code (NEC), local electrical and safety codes, and when applicable, the Occupational Safety and Health Act (OSHA) should be observed to reduce hazards to personnel and property. The control does not provide motor over temperature protection. The user is responsible for providing this protection in the equipment where this control is used (Remarque: La detection de la surchauffe du moteur n'est pas assuree par cette control). Step 1: Mounting the Control The control may be mounted using any two or all four mounting holes. The mounting holes have clearance for 1/4-20 or M6 screws. Step 2: Preliminary Setup HORSEPOWER & ACCELERATION SELECTOR SWITCHES-Control models 0790 and 0791 are packaged with the enclosure cover unattached. Remove the cover to set the horsepower and acceleration selector switches. Figure 4 shows the location of a bank of 8 dip switches. Set switches 1 through 6 to match the type, speed, and current ratings on the Bodine motor nameplate per Figure 2 (consult Bodine on settings for non-Bodine motors). Set switches 7 and 8 to select the acceleration/ deceleration time range per Figure 3. Step 3: Electrical Connections The enclosure cover must be removed as shown in Figure 4 to make the electrical connections. WARNING-All parts of the circuit operate at voltages capable of causing serious injury or death. WARNING-The AC power line to the control should be the last connection made. CAUTION-The control board signal common is not at ground potential. Any external signal or equipment connected to the control must be electrically isolated from ground. INHIBIT SWITCH (OPTIONAL)-A mechanical switch or relay with contacts rated for low voltage may be connected to terminals "H1" and "H2". With the switch open, the motor will run. With the switch closed, the motor will coast to a stop. WARNING-The inhibit switch should not be used to disable motor or control when servicing these or driven equipment. Disconnect the AC power instead. 1. For armature speed of a geared motor, multiply the output speed at the driveshaft by the gear ratio. 2. If the user desires to install their own armature fuse on the control output to protect the motor from continuous overloads, base fuse ratings on the motor rating in this column. 3. Peak current available with TORQ pot in fully CW position (factory setting). This current exceeds the continuous rating of the motor and is for intermittent overload conditions only. 4. Use this column for sizing a line fuse on the control input. 5. The REG potentiometer must be turned fully CCW (off) for high-speed type 24ABEPM motor. 6. Time for voltage across A1 and A2 to ramp up to 130 V when speed pot is turned from 0 to 100; or to ramp down to 0 V when it is turned from 100 to 0. The time for a motor to accelerate from 0 to 2500 rpm or decelerate from 2500 to 0 rpm is dependent on motor size and loading conditions. www.bodine-electric.com | [email protected] | 19225 Kapp Drive, Peosta IA, 52068-9547 U.S.A. | Tel: 773.478.3515
Open the catalog to page 1INSTALLATION, continued MOTOR CONNECTIONS–Feed the motor cable through the opening in the bottom of the enclosure. For clockwise armature rotation, connect the “+” motor wire (white wire on Bodine motors) to terminal “A2” and the “–” motor wire (black wire on Bodine motors) to terminal “A1”. For counterclockwise rotation, reverse the motor connections. Reinstall enclosure cover. LINE FUSE–Models 0790 and 0791 are equipped with a fuseholder on the front panel that is accessible to users for field replacement of the fuse. A four amp fuse is factory installed in model 0790 and an eight amp fuse...
Open the catalog to page 224 Pages
2 Pages
24 Pages
20 Pages
2 Pages
2 Pages
52 Pages
252 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
52 Pages