Pacesetter AC Motor Speed Control Model 2998 Overview
The Bodine Electric Model 2998 is a 3-phase AC motor speed control designed for 230 VAC, 50 or 60 Hz inverter-duty motors ranging from 1/8 HP to 1 HP. It operates from a single-phase 115 or 230 VAC line and is housed in a NEMA-1 / IP-40 rated enclosure, suitable for basic environmental protection. This model is ideal for applications such as conveyors, packaging equipment, and industrial machinery.

Key Features
  • Simple operation with factory-set trimpots and jumpers.
  • Motor horsepower selection jumper for a wide range of motor HP.
  • Diagnostic LEDs for power, drive status, and overload indication.
  • Run/Fault relay output contacts for equipment control and fault signaling.
  • Barrier terminal blocks for easy wiring.
  • Jumper selection for drive output frequency to increase motor speed up to twice the rated RPM.
  • Motor overload protection with RMS current limit to prevent burnout.
  • Electronic inrush current limit to eliminate harmful startup currents.
  • Short circuit protection and regeneration to prevent tripping due to bus overvoltage.
  • Overvoltage and undervoltage protection to shut down the drive if input voltage is out of range.
  • Built-in line filter for CE compliance and input transient suppression.

Specifications
  • Line Input Voltage: 115 VAC (±15%) or 208/230 VAC (-15%/+15%).
  • Horsepower Selection: 1/8, 1/4, 1/2, 3/4, 1 HP.
  • Acceleration/Deceleration Time: 0.3-20 seconds (factory set to 1.5 seconds).
  • Output Frequency Multiplier: 1X or 2X (factory set to 1.0).
  • Operating Temperature Range: 0-45°C.

Electrical Ratings
  • 115 VAC: Max Current 16 Amps, Fuse 20 Amps, Output 0-230 VAC, Max Current 3.6 RMS Amps/Phase, Max HP 1.
  • 208/230 VAC: Max Current 10 Amps, Fuse 15 Amps, Output 0-230 VAC, Max Current 3.6 RMS Amps/Phase, Max HP 1.

Control Layout and Dimensions
The control layout includes various jumpers and trimpots for settings such as motor horsepower, frequency, and relay outputs. The dimensions are provided for installation, with a recommended tightening torque for the cover screws. The unit weighs 2.4 lbs.
See more

Catalog excerpts

2998-1

Pacesetter AC Motor Speed Control Model 2998 NEMA-1 / IP-40 The Bodine Electric model 2998 3-phase AC motor speed control is designed to drive 230 VAC, 50 or 60 Hz, inverter-duty, 3-phase gearmotors and motors ranging from 1/8 HP to 1 HP (746 watts). It operates from a single-phase, 115 or 230 VAC line, and is housed in a NEMA-1 / IP-40 rated enclosure for basic environmental protection. The control is designed for applications such as conveyors, packaging equipment, door and gate openers and other industrial equipment. • Simple to Operate: does not require programming. Uses trimpots and jumpers, which are factory set for most applications • Motor Horsepower Selection Jumper: allows the drive to be used on a wide range of motor HP • Diagnostic LEDs: PC board mounted LEDs for power on, drive status, and overload • Run/Fault Relay Output Contacts: turns on or off equipment. Signals stop mode or if a fault has occurred • Barrier Terminal Blocks: facilitates wiring • Jumper Selection of Drive Output Frequency: increases the motor speed up to two times the rated RPM • Motor Overload (I 2 t) with RMS Current Limit prevents motor burnout and nuisance trips • E lectronic Inrush Current Limit: eliminates harmful inrush AC line current during startup •S hort Circuit: shuts down the drive if a short circuit occurs at the motor (phase-to-phase) •R egeneration: eliminates tripping due to bus overvoltage •O vervoltage and Undervoltage: shuts down the drive if the AC line input voltage goes above or below the operating range •O n/Off Switch, Speed Pot, F-S-R Switch •B uilt-in Line Filter: for CE compliance • I nput transient suppression www.bodine-electric.com for our complete line of AC inverter duty gearmotors, motors and controls Electrical Ratings AC Line Input Max. Current Fuse (VAC) Phase (Amps AC) (Amps) 115 208/230 Output Voltage Range Max. Current1 (Amps) (RMS Amps/Phase) 0-230 0-230 NOTE: 1. Dependent on motor performance. General Performance Specifications Description Specifications Factory Setting 115 VAC Line Input Voltage Operating Range (VAC)1 . . . . . . . . 115±15% — 208/230 VAC Line Input Voltage Operating Range (VAC) . . . . . . . 208 (-15%) / 230 (+15%)2 Horsepower Selection (HP) (J2) . . . . . . . . . . . . . . . . . . . . . . . . . . 1/8, 1/4, 1/2, 3/4, 1 1 Acceleration Time (Seconds) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.3-20 1.5 Deceleration Time (Seconds) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.3-20 1.5 1.0 Output Frequency Multiplier (1X, 2X) (Jumper J4)3 . . . . . . . . . . 1, 2 — Speed Reg. (30:1 Speed range, 0-full load; % base speed)4 . . . 2.5 Overload Protector Trip Time for Stalled Motors (Sec.) . . . . . . . . 6 — Run/Fault Relay Output Contact Rating . . . . . . . . . . . . . . . . . . . . . 1, 0.5, 0.25 — (Amps @ 30V DC, 125 V, 250 VAC) Operating Temperature Range (°C) . . . . . . . . . . . . . . . . . . . . . . . . . 0-45 — 1 . Do not operate the drive outside the specified AC line input voltage operating range. 2. The drive is factory set for 208/230 Volt AC line input (Jumper J1 not installed). For 115 Volt AC line input, install Jumper J1. 3. Allows the motor to operate up to two times the rated RPM. Constant motor horsepower will result when operating the drive in the “2X” mode above the motor nameplate rated RPM. 4. Dependent on motor performance. 201 Northfield Road | Northfield, IL 60093 U.S.A. | 800-7BODINE | Outside U.S.A. +001-773-478-3515 | Fax: 773-478-3232 | www.bodine-electric.com

 Open the catalog to page 1
2998-2

Pacesetter AC Motor Speed Control Model 2998 NEMA-1 / IP-40 Dimensions Weight: 2.4 lbs. "Knockouts" for Standard 3/4" Fittings Side view is shown dimensioned with the cover installed. Recommended tightening torque for the two front cover screws: 5 in-lbs (6 kg-cm). Back view is shown dimensioned without the cover installed. A mounting template is included to facilitate mounting of the drive. Control Layout Jumpers and trimpots are shown in factory set positions. Panel Mounted Main Speed Potentiometer (Front View) J1: AC Line Input Voltage selection. Install jumper for 115 Volt AC line input....

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.