PLA34

PLA34

PLA34

Product catalog summary
Overview: The PLA34 is a power quality analyser designed for panel mounting, compliant with IEC 61000-4-30 class S standards. It is equipped with three voltage and four current inputs, suitable for low and medium voltage systems. The device is built on a 32-bit RISC processor, ensuring real-time measurement and calculation capabilities.
Specifications:
  • Continuous sampling at 40 kHz for high accuracy.
  • Four voltage and four current measuring inputs.
  • Fourier analysis from 1st to 65th harmonics for various parameters.
  • Harmonics and inter-harmonics measurement according to EN 61000-4-7.
  • Short and long-term flicker measurement as per EN 61000-4-15.
  • Transient detection > 25 µs and event detection > 10 ms.
  • 1GB flash memory for data logging, events, and transients.
  • Communication interfaces include RS485, Ethernet, and USB.
  • Additional digital and analogue outputs/inputs via RS485 expansion module.
Measured Parameters:
  • Voltage range: 10 ... 600 VAC (L-N), 18 ... 1000 VAC (L-L).
  • Current range: 1 mA ... 6 (8.5) A without transformer.
  • Frequency: 40 ... 70 Hz.
  • Power factor, THD, harmonics, and flicker measurements.
  • Active, reactive, and apparent power and energy measurements.
Technical Features:
  • Power supply: 85 ... 265 VAC/DC.
  • Operating temperature: -25°C to +60°C.
  • Dimensions: 96 x 96 x 75 mm, weight: 525 g.
  • Protection class: IP20 rear cover / IP54 front panel.
  • Communication protocols: Modbus RTU, Modbus TCP, SNTP, HTTP, FTP, email.
  • Internal web server for remote monitoring.
Compliance and Standards: The PLA34 complies with EN61000-4-30 S, EN61000-4-7, EN61000-4-15, and EN61557-12 standards, ensuring reliable performance in various network conditions.
See more

Catalog excerpts

PLA34-1

PLA34 power quality analyser panel mounting quality analyser according IEC 61000­4­30 class S The power quality analyser PLA34 is designed according to norm EN 61000­4­30 class S, with three voltage and four current inputs for measurement of electrical parameters in LV and MV systems. PLA34 is built on a 32 bit RISC processor that provides sufficient processing capabilities for real­time measurement and calculation of all parameters & values. Continuous sampling of the voltage and current inputs at 40 kHz, guarantees the highest accuracy. The PLA34 is the instrument for power quality monitoring according to EN 50160 of the incoming energy supply side as well as on the consumer side in order to find and analyse the root cause of network problems. • Measurement of power quality according to the EN 61000­4­30, class S • Continuous sampling of voltage and current inputs at 40 kHz • 4 voltage measuring inputs and 4 current measuring inputs • Fourier analysis from 1st to 65th harmonics of U L­N, U L­L, I, P (+/­) and Q (L/C) • Harmonics and inter­harmonics measurement of U L­N, U L­L, I according to EN 61000­4­7 • Short term and long term flicker measurement according to the EN 61000­4­15 • Detection of transients > 25 µs • Detection of events > 10 ms • Measured data logger, event and transient memory 1GB flash • RS485, Ethernet, USB • 2 built in digital inputs / outputs • Additional digital and analogue outputs and inputs via RS485 expansion module BMR trading, Horní lán 17, 779 00 Olomouc, Czech Republic, tel.: +420 778 066 566, export@bmr­trading.com, www.bmr­trading.com

 Open the catalog to page 1
PLA34-2

PLA34 power quality analyser panel mounting quality analyser according IEC 61000­4­30 class S Measured parameters Parameter Phase voltage Line voltage Frequency Current Cosφ Power factor THDU L­N THDU L­L THDI Harmonics U Group of interharmonics U Group of harmonic U Harmonics P Harmonics Q Harmonics I Group of interharmonics I Group of harmonics I Min AVG Maxavg Measuring range Displayed range Short term flicker Long term flicker Undervoltage U Overvoltage U Unbalance U Neutral point displacement K­factor Ripple control signal Active power Reactive power Apparent power Distortion power Active...

 Open the catalog to page 2
PLA34-3

PLA34 power quality analyser panel mounting quality analyser according IEC 61000­4­30 class S Technical features Parameter Power supply voltage Measuring voltage L­N (without voltage transformer) Measuring voltage L­L (without voltage transformer) Current range (without current transformer) Grid type Number of outputs / inputs Output type NPN transistor free potential optical insulated Voltage and current transformer ratio Sampling frequency Events trigger Communication interfaces Communication protocols Modbus RTU, Modbus TCP, SNTP, HTTP, FTP, email Over­voltage class Pollution degree Working...

 Open the catalog to page 3

All BMR trading catalogs and technical brochures

  1. FCR05/07

    2  Pages

  2. FCR06/12

    2  Pages

  3. PLA33

    3  Pages

  4. PLA34RGP

    3  Pages

  5. PLA44

    3  Pages

  6. PLA44RGP

    3  Pages

  7. Catalogue

    44  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.