Catalog excerpts
PLA33 power line analyser s i m p l y Power line analyser PLA33 is a modern device for multifunction monitoring of main electrical parameters in threephase network. Device measures parameters according to norm IEC 61000430 and it is ideal for very precise power management. Internal memory and communication interface define the PLA33 being used as power monitoring recorder or part of SCADA systems. • 4 quadrant continual measurement • monitoring of U in every phase and phasephase • monitoring of I in every phase • calculated current in neutral wire • system frequency • THD U and THD I • odd harmonics of U and I till 19th (L1, L2, L3) • power factor (L1) and cosφ (L1, L2, L3) • P+/, Q+/, S (L1, L2, L3, ∑) • Eactive+/, Ereactive+/ (L1, L2, L3, ∑) • internal current transformers ICT • measurement according the standard IEC 61000430 • measuring phasephase voltage from 0 ... 520 VAC • auxiliary power supply • memory for recording of maximums / minimums • memory for recording of 20 power cut events • internal realtime clock • communication interface RS485 with Modbus RTU protocol • internal memory 512MB for measured parameters recording • minimum internal memory sampling period 60s (AVG value) • two independent digital input / output BMR trading, Horní lán 17, 779 00 Olomouc, Czech Republic, tel.: +420 778 066 566, export@bmrtrading.com, www.bmrtrading.com
Open the catalog to page 1PLA33 power line analyser s i m p l y Measured parameters Parameter Measuring range Displayed range Current in neutral calculated ● Power factor THDU, L N Reactive inductive energy +/ Reactive capacitive energy +/ Supply voltage interuptions Device variants Type Flash memory Energy memory panel panel panel DIN rail DIN rail DIN rail DIN rail BMR trading, Horní lán 17, 779 00 Olomouc, Czech Republic, tel.: +420 778 066 566, export@bmrtrading.com, www.bmrtrading.com
Open the catalog to page 2PLA33 power line analyser s i m p l y Technical features Parameter Power supply voltage System frequency Current range (without current transformer) Measuring voltage LN (without voltage transformer) Measuring voltage LL (without voltage transformer) Grid type TN, TT, IT (with virtual resistor N bridge) Power consumption Sampling frequency Number of outputs / inputs Output type Open collector, free potential optical insulated (S0) Data memory 512 MB Flash memory (PLA33CMB variant) Minimum flash recording interval Powercut event memory Voltage and current transformer ratio Communication...
Open the catalog to page 3