Catalog excerpts
Digital and Analogue Inputs and Outputs Spindle Connection (DeskTop) Spindle Connection SSE Mains Supply 7.1 View at the Front Panel 7.2 Configuration of Rotational Speed 7.3 Configuration of Direction of Rotation 7.4 Selection of Spindle Characteristics 7.5 Starting and Stopping the Frequency Converter 7.6 Remote controlled Configuration of Direction of Rotation 7.7
Open the catalog to page 3Depending on its construction, the speed of a three‐phase asynchronous AC motor is directly dependent on the number of poles and the frequency of the voltage network. In a 3ph/50Hz network, with a 2‐pole motor, the rated speed would be 50 U/s * 60 = 3000 rpm. With synchronous motors (brushless DC), the speed is dependent on the voltage applied. Three‐phase AC motors offer numerous advantages in industrial applications, such as brushless drive, no wear, favourable power/weight ratio, high speed capability, and much ...
Open the catalog to page 4Description and Features Operation of Asynchronous‐AC –Spindles With optionally available integrated sinusoidal filter for special smoothing of the output signal and operation of low‐voltage spindles. This ensures high attenuation of interference emissions on the motor cables The frequency converter SFU 0300 allows output frequencies up to 4000 Hz / 240.000rpm with 2‐pole asynchronous‐AC‐motors. High Output power (1500VA/S1‐100% ) in a compact format The Kernel of the SFU‐0300 is a Digital Signal Processor (DSP), which generates all output variables and captures signals. ...
Open the catalog to page 5Block Diagram
Open the catalog to page 6Continuous Current Peak Phase Current Spindle characteristics Control inputs ATTENTION: Please ensure to have the proper spindle characteristic selected, always! The operation of a spindle with a wrong characteristic may harm the spindle or converter severely! A
Open the catalog to page 7Safety‐Precautions and Warnings This device produces dangerous electrical voltages and is used for the operation of fast spinning tools. Because of their high rotational speed, it may be dangerous in case of improper handling. For this reason, only professionally trained and qualified personnel should be allowed to work with and setup this device! Before the first commissioning can be carried out, it should be ensured that the spindle and the tool are fixed properly, to eliminate all dangers because of uncontrolled movement of the spindle. ...
Open the catalog to page 8Connections, Interfaces and Pinouts Operational parameters and outputs: The SFU 0300 covers all current important operational parameters and operating data. Up to 5 digital outputs can be used for signalling and 1 analogue value (0...10V) can be output at the analogue output. Remote Control and Outputs: 3 digital inputs (0/24V) and 1 analogue inputs (0...10V) are available for remote control of the SFU 0300. These assignments can be freely configured. Using the optional Windows PC software SFU‐...
Open the catalog to page 9with 7 pin female jack (Amphenol C16-1 / Binder 693) Spindle Temperature 3 V Spindle Phase 2 4 FP FP-Signal / Speed Sensor Temperature Sensor-Signal 7 PE Protective Earth 6.4 Mains Supply SSE 3 pin. pluggable screw terminals, 4mm2 Desktop IEC60320 C14 3 pin. mains jack for detachable mains cord
Open the catalog to page 117. Functions, Setup, Operation 3 operational possibilities: Control and configuration manually via front keys Automatic control and configuration via PLC / IPC Automatic control and configuration via PC (RS232 interface) The errors can be evaluated with the help of the windows software SFU‐Terminal, which is available on the website. The documentation of this software shows how evaluation of these errors is possible. ATTENTION: Where several spindles are in use within one system, the user must ensure that these are of the s
Open the catalog to page 12The preset of revolutions per minute of the spindle can be achieved by three ways: Preset manually with the radio knob on the front panel Preset via analogue input Set Value Rotational Speed The default scaling for this input is set up to 1V/10.000rpm Preset via RS232 interface The direction of rotation can be set up before start. For this the key STOP has to be pressed approx. 4sec. In the setup mode it can be switched with the START STOP ‐keys alternating between Right and Left. Right means clockwise rotation with view to the back side of the spindle ...
Open the catalog to page 13Due to many different requirements, there are several possibilities for starting and stopping the SFU 0300 frequency converter: Manually with the panel keys controlled remotely via a digital input controlled remotely via an analogue input controlled remotely via serial interface In every case, with the exception of analogue start, the start of the converter is only possible, if a preset of the rotational speed is set up. Manually via panel keys Activation of spindle start via the green START key. Spindle‐stop is activated by the red STOP key on the operator panel. ...
Open the catalog to page 147.6 Remote‐Controlled Configuration of Direction of Rotation via Digital Inputs This can be achieved via the digital input Direction of Rotation . The setup can be done with SFU‐Terminal software in the menu "Digital Inputs": This is necessary, if the direction of rotation has to be controlled , for example, via a PLC. Reversal can only take place once the spindle / motor has come to a complete stop. If the direction pre‐selection setting is changed whilst the spindle / motor is running, the spindle ...
Open the catalog to page 15The setup of this device can be done in a very flexible and comfortable way with the help of our Windows PC‐Software software SFU‐Terminal. It is available on CD or on our website www.bmr‐gmbh.de/html/british/dokumente/bediensoftware.htm for free. It is possible to administrate spindle characteristics or to configure the functions of inputs and outputs. Moreover there are further functions and useful tools available Die Parametrierung des Geräts ist mit Hilfe der PC‐Software SFU‐Terminal vielseitig und ...
Open the catalog to page 16All BMR GmbH catalogs and technical brochures
-
Catalogue
52 Pages
-
SFU 0102
28 Pages
-
SFU 400
15 Pages
-
SFU 0303
56 Pages
-
SFU 0103/0203
30 Pages
-
SFU 0303
56 Pages
-
SFU-ErrorFlags
7 Pages
-
RS232 Control Commands
6 Pages
-
SpindlecoolerKG-T 500
24 Pages
-
DressView
32 Pages
-
Folnet P S / P S 300
8 Pages
-
Folnet P
8 Pages
-
Folnet3-NT
8 Pages
-
Folnet 1 NT
8 Pages
-
Folnet 1
8 Pages
-
Folinv 12/3
4 Pages
-
SFU 0401
10 Pages
-
SFU 0302 19”
28 Pages
-
SFU 0302 SSE
30 Pages
-
SFU 0101/0201
17 Pages
-
SFU 0100
2 Pages
-
SFU 0303/4
48 Pages
-
SFU 0303/2
50 Pages
-
SFU0052
12 Pages
-
SFU 0200/1
24 Pages
-
SFU 0103
24 Pages
-
SFU 0156
20 Pages
-
SFU 0150
20 Pages
-
SFU 0102/0202
28 Pages
-
KG-T 500
20 Pages