Catalog excerpts
Content 1 Introduction 2 Description and Features 3 Block Schematic 4 Technical Data 5 Safety and Caution Instructions 6 Connections, Plugs and Pin Assignments 6.1 Analogue Input and Digital Outputs 6.4 USB Interface 7 Description of Functions and Operation 7.3 Set Value of Rotational Speed
Open the catalog to page 2bmR 1. Introduction The SFU0052 is the successor of the SFU051 and can replace it directly with the exception that the spindle characteristics of the DC version are different and can not be interchanged, but are available at BMR on request. It is implemented an improved DC functions which grants a much better overall performance. The rotational speed of BLDC (brushless direct current) motors is direct depending on the voltage applied. Generally this voltage will be connected to a 3 phase winding on the rotor via a collector, which takes over the proper commutation. BLDC motors have the...
Open the catalog to page 3lamp3. Block Schematic PLIM Pouer Supply
Open the catalog to page 4This device produces dangerous electrical voltages and is used for the operation of fast spinning tools. Because of their high rotational speed, it may be dangerous in case of improper handling. For this reason, only professionally trained and qualified personnel should be allowed to work with and setup this device! Any maintenance to the device must be carried out after the supply voltage has been disconnected, only! Before the first commissioning can be carried out, it should be ensured that the spindle and the tool are fixed properly, to eliminate all dangers because of uncontrolled...
Open the catalog to page 5lamp6. Connections, Plugs and Pin Assignments 6.1 Analogue Input - Digital Output X1 6 pol. pluggable screw terminal 3,5mm 6.4 Interface USB For communication with PC and setup and remote control with the help of SFU-Terminal
Open the catalog to page 67. Description of Functions and Operation SFU 0052-SSE gets all important operating conditions and parameters. A selection of two can be output on the digital outputs as messages All setups described below can easily be carried out with the help of SFU Terminal with a Version higher than V5.9 . The multi purpose input X1-PIN 1 input can be used for setting up the desired rotational speed and in combination for START-STOP During operation the current status is displayed at the LEDs ERROR, RUN, READY The LED ERROR is additionally a common indication for an error. Start and Stop of the...
Open the catalog to page 7• Another option of the input scaling is 1V/10.000rpm. As soon as the spindle is started the rotational speed can be increased to maximum The analogue input is protected agains voltages beyond 10V for short time and not for permanent duration 7.4 Load Display At the LED bar the current load condition is displayed as fractions of 100%. As soon as the maximum load is superceded the red LED is lit and the relay at X1-PIN 2-3 is switch. In case that this condition is persisting longer than 10s or longer as the value set up with SFU-Terminal, the spindle is stopped. (see 7.5) 7.5 Status LEDs and...
Open the catalog to page 8bmR 5. Safety Functions The following safety functions bring about controlled stop of the spindle according predefined deceleration times • Safety stop because of converter excess temperature after delay-time of 10s is exceeded • Safety stop by overload and time delay exceeded (default 10sec) • Safety stop will occur immediately by exceeding the maximum admissible spindle current. 6. EMC This device was developed for use in industrial environments. For trouble-free operation and to reduce emitted interference, the following should be observed during wiring of the equipment: • The EMC of a...
Open the catalog to page 10e-mail: Info@bmr-gmbh.de Internet: www.bmr-gmbh.de Subject to technical alterations. Issue : 22.10.2014
Open the catalog to page 12All BMR GmbH catalogs and technical brochures
-
Catalogue
52 Pages
-
SFU 0102
28 Pages
-
SFU 400
15 Pages
-
SFU 0303
56 Pages
-
SFU 0103/0203
30 Pages
-
SFU 0303
56 Pages
-
SFU0300
24 Pages
-
SFU-ErrorFlags
7 Pages
-
RS232 Control Commands
6 Pages
-
SpindlecoolerKG-T 500
24 Pages
-
DressView
32 Pages
-
Folnet P S / P S 300
8 Pages
-
Folnet P
8 Pages
-
Folnet3-NT
8 Pages
-
Folnet 1 NT
8 Pages
-
Folnet 1
8 Pages
-
Folinv 12/3
4 Pages
-
SFU 0401
10 Pages
-
SFU 0302 19”
28 Pages
-
SFU 0302 SSE
30 Pages
-
SFU 0101/0201
17 Pages
-
SFU 0100
2 Pages
-
SFU 0303/4
48 Pages
-
SFU 0303/2
50 Pages
-
SFU 0200/1
24 Pages
-
SFU 0103
24 Pages
-
SFU 0156
20 Pages
-
SFU 0150
20 Pages
-
SFU 0102/0202
28 Pages
-
KG-T 500
20 Pages