Catalog excerpts

SFU 400 - 1

…when it comes to quality! BMR GmbH

Open the catalog to page 1
SFU 400 - 2

Technical Data Safety Precautions and Warnings Connections, Plugs and PIN Assignments Power Supply Connection X1 Spindle Connection X2 Interface RS232 Input and Output Connections X3 Connection and Mounting Start and Stopp Set Value of Rotational Speed Outputs LED Status Indication Example for I/O Connection Safety Functions Remote Control Unit

Open the catalog to page 2
SFU 400 - 3

The SFU400 is developed for the operation of AC-asynchron- and DC-synchron-spindles. speed frequencies up to 1666Hz/100.000 rpm with this 2-pole AC spindle are possible The core of SFU400 is a digital signal processor (DSP) which produces all output parameters and collects signals. High-precision sinusoidal output signals with a low distortion factor and low deformation allow for optimal rotation qualities in AC motors of all operating conditions. All parameters like power, voltage and frequency are collected in real time and are regulated by the implemented vector control depending on the...

Open the catalog to page 3
SFU 400 - 4

The SFU400 inverter is a built-in device intended for installation in stationary electrical, industrial and commercial installations or machines. When installed in machines, it is forbidden to commission the inverter and thus start its intended operation until the machine complies with the Machinery Directive 2006/42/EC. EN 60204 (DIN VDE 0113) must be observed. The machine may only be put into operation for its intended purpose if the EMC Directive (2004/108/EC) is observed. This device produces dangerous electrical voltages and is used for the operation of fast spinning tools. Because of...

Open the catalog to page 4
SFU 400 - 5

Connection, Plugs and Pin Assignments LEDs (→ 5.4) X1 Connection for Power Supply 4.1 Power Supply Connection X1 (Screw terminals for strands or wires up to 0,75mm ²) Pin Function +Power Supply -> Fuse FS1 7AT GND - Return of Power Supply Protection Earth, electrically connected with mounting plate Attention, no protection against reversed polarity! 4.2 Spindle Connection X2 (Screw terminals for strands or wires up to 0,75mm ²) Pin Protection Earth, electrically connected with mounting plate 4.3 Interface RS232 Connection X4 (Pin Header Würth WR-WTB_648103131822) 1 Attention, Interface is...

Open the catalog to page 5
SFU 400 - 6

4.4 Inputs and Outputs Connection X3 (Screw terminals for strands or wires up to 0,75mm ²) Pin Function Digital Input1 - Start / Stopp Analog Input1 - Set Value Rotational Speed Ground for Pin 1, 2, 4, 5 ( internally connected with X1-0V) Converter and Spindle ready Temp Sensor Input Spindle - Threshold variable to be set up Input Impedance ANL_IN: 60kOhm, Open Collector: 45V/0,5A A Remote Control Unit is available on option for direct connection with the I/O (→ 9.). X1 Connection for Power Supply The PE connections of spindle and power supply can be connected at X2. For a good shield...

Open the catalog to page 6
SFU 400 - 7

Functions, Setup and Operation 5.1 Start / Stopp There are two possibilities to start the spindle: digitally with a digital control signal at digital input1 Start/Stop at X3.DIG_IN. The switching levels for "OFF=0" are 0...5V and for "ON=1" 13...24V, Voltage level between 5V and 13V are undefined. ➔ As soon as this is initiated, the spindle will be accelerated to the set value of the rotational speed which is pre-selected as voltage at analogue input Set Value of Rotational Speed at X3.ANL_IN. analogue with a voltage at X3.ANL_IN Precondition is a valid "ON" signal at digital input...

Open the catalog to page 7
SFU 400 - 8

5.4 LED Status Indication At the LEDs the current operating status of the SFU0060 is indicated Converter Standstill - No Error Blink fast Converter is accellerating- No Error Set Value Duty Speed reached - No Error Duty Speeed reached - Overload Spindle - Time Delay counting (1) Overload Spindle - Delay Time elapsed Blink fast Power Stage switched off - immediate shutdown with reaching the threshold (3) Blink long-short too much back-energy of the spindle during ramp down - immediate shutdown (5) No Spindle detected / Spindle Cable defective Overtemperature SFU - switch off after elapsed...

Open the catalog to page 8
SFU 400 - 9

Example for connecting the I/O Interface For a successful start of the spindle the analogue voltage at ANL_IN has to be higher than the Min-Voltage for Stopp. (→ 5.2). With using a potentiometer for dialing the rotational speed it should be wired to 10V, so that the required range from 0…10V can be covered, representing the speed range. Attention: All these works handle with dangerous voltage and have to be carried out by skilled persons only. Please verify before connecting that the supply voltage is switched off! Attention: Before commissioning, please make sure that all connection...

Open the catalog to page 9
SFU 400 - 10

Safety Functions The following safety functions bring about controlled stop of the spindle according predefined deceleration times: Safety Stop because of converter excess temperature after elapsed delay-time Safety Stop because of overload after elapsed delay-time (default 10sec) Immediate-Stop because of exceeding the maximum permissible spindle current When ramping down an asynchronous spindle it can happen that the voltage generated in the spindle will exceed the maximum permissible value. This is detected by the converter and the power stage is switched off for self protection. In this...

Open the catalog to page 10
SFU 400 - 11

USB-Interface für SFU400 On option a remote control unit for direct interfacing with the I/O connection X3 is available. Herewith the communication with the SFU terminal V7.5 for parameterization and debugging is possible very comfortably. …when it comes to quality! BMR GmbH

Open the catalog to page 11
SFU 400 - 12

SFU400 with Remote Control-Adapter On option a remote control unit for direct interfacing with the I/O connection X3 is available. With the help of this unit the converter can be controlled very easily without any further wiring. Starting and stopping becomes possible and all functions can be tested before commissioning and without external control signals. The remote control unit is operated with 3 x AAA Batteries or Accus . All relevant voltages are generated within the adapter For power saveing, an ON/OFF switch is provided. The ready state is indicated at the LED Batt. ON. The switch...

Open the catalog to page 12

All BMR GmbH catalogs and technical brochures

  1. Catalogue

    52 Pages

  2. SFU 0102

    28 Pages

  3. SFU 0303

    56 Pages

  4. SFU 0103/0203

    30 Pages

  5. SFU 0303

    56 Pages

  6. SFU0300

    24 Pages

  7. DressView

    32 Pages

  8. Folnet P

    8 Pages

  9. Folnet3-NT

    8 Pages

  10. Folnet 1 NT

    8 Pages

  11. Folnet 1

    8 Pages

  12. Folinv 12/3

    4 Pages

  13. SFU 0401

    10 Pages

  14. SFU 0302 19”

    28 Pages

  15. SFU 0302 SSE

    30 Pages

  16. SFU 0101/0201

    17 Pages

  17. SFU 0100

    2 Pages

  18. SFU 0303/4

    48 Pages

  19. SFU 0303/2

    50 Pages

  20. SFU0052

    12 Pages

  21. SFU 0200/1

    24 Pages

  22. SFU 0103

    24 Pages

  23. SFU 0156

    20 Pages

  24. SFU 0150

    20 Pages

  25. SFU 0102/0202

    28 Pages

  26. KG-T 500

    20 Pages