video corpo

SFU 0303/4
48Pages

{{requestButtons}}

Catalog excerpts

SFU 0303/4 - 1

…when it comes to quality! BMR GmbH

Open the catalog to page 1
SFU 0303/4 - 3

5 Safety Precautions and Warnings 6 Connections, Interfaces and Pinout 6.1 Digital and Analogue Inputs and Outputs 10 6.3 Version SSE: Mains Connector, Spindle Connector 13 6.4 Version 19": Mains Connector, Spindle Connector 14 6.5 Version Desktop: Mains Connector, Spindle Connector 15 7 Functions, Setup, Operation 7.1 Front panel of SSE, Desktop und 19" Version 18 8 Setup with Windows-Software 9 Automatic Spindle Tuning 11.1 Mains and Spindle Connection 11.2 Logic and Wiring for Safety 16.1 SEE Version for cabinet mounting 17 Other products of BMR GmbH...

Open the catalog to page 3
SFU 0303/4 - 4

Introduction Due to its construction, the rotational speed of a 3-phase AC motor is directly dependent on the frequency of the voltage and the number of poles. In case of a 3PH 50Hz voltage and a 2-pole motor, the nominal speed would be 50 rps * 60 = 3000 rpm. In case of BLDC motors (brushless dc), the speed is directly dependent on the voltage applied. 3-phase AC motors provide numerous benefits in industry, such as brushless operation, freedom from wear and tear, favorable capacity/weight ratio, high-speed capability, and much more. These motors can be used many different application...

Open the catalog to page 4
SFU 0303/4 - 5

Start/Stop Interface for periodical tests or remote control Operating panel is detachable and can be used as remote control together with an extension cable Designed for roughest use in industrial environment The housing of SSE is realized without ventilations slots and an outside mounted heatsink. preventing by this the intrusion of dirt and chips of tooling. Very compact case style makes easy cabinet mounting possible Several case options for cabinet mounting (SSE) , 19" rack style and desktop, or special designs on request User friendly Screw-plug connector system for power-, spindle-...

Open the catalog to page 5
SFU 0303/4 - 6

S Operation of Asynchronous AC und BLDC Motors S The high frequency converter SFU-0303 makes possible output frequencies 3.3 kHz / 200.000 Upm with 2pole AC-Motors and with BLDC-Motors up to 100.000rpm S High output power ( 3,6kV @ 230V / 2kVA @ 115V ) in compact style S The core of SFU-0303 is a Digital Signal Processor (DSP) which produces all output signals and collects all input signals S All parameters like current, voltage and frequency are collected in real time and are regulated by the implemented vector control depending on the load condition. S High precision sinusoidal output...

Open the catalog to page 6
SFU 0303/4 - 7

Block Diagram …when it comes to quality! BMR GmbH

Open the catalog to page 7
SFU 0303/4 - 9

Operating conditions 5 - 40°C / rel. Humidity of air max. 85% A The operation of a spindle with a wrong characteristic may harm the spindle severely! Please ensure to have the proper characteristic selected always!

Open the catalog to page 9
SFU 0303/4 - 10

Safety- Precautions and Warnings This device produces dangerous electrical voltages and is used for the operation of fast spinning tools. Because of their high rotational speed, it may be dangerous in case of improper handling. For this reason, only professionally trained and qualified personnel should be allowed to work with and setup this device! Before the first commissioning can be carried out, it should be ensured that the spindle and the tool are fixed properly, to eliminate all dangers because of uncontrolled movement of the spindle. Safety regulations being valid for the country...

Open the catalog to page 10
SFU 0303/4 - 11

Connections, Interfaces and Pinouts For embedding into PLC and controls the SFU0303 has several input and outputs. They are realized as pluggable screw terminals and are located at the front or rear panel (depending on case option). All contacts are separated galvanically from high voltage carrying circuits. Operational parameters and outputs: The SFU-0303 captures all current important operational parameters and operating data. Up to 6 digital outputs can be used for signaling and up to 2 analogue values can be output to the analogue outputs (0-10V). Remote Control and Outputs: 6 digital...

Open the catalog to page 11
SFU 0303/4 - 12

6.1 Digital and Analog Inputs and Outputs (25 pin D-sub female) Version SSE on front panel 19", Desktop, Desktop 63TE on back panel

Open the catalog to page 12
SFU 0303/4 - 13

+VFP SGND FP PTC W V U Rext +ZU PE View at screw terminals at version SSE: The device has no internal fusing. It has to be fused externally A Please ensure, that PE protective earth is connected at the mains side. The device must not be operated without properly connected PE! A Please ensure, that PE protective earth is connected at the spindle side as well as at the mains side. Control wires, Mains cables and spindle cables should be installed separately. For wiring, the use of shielded cables is recommended.

Open the catalog to page 13
SFU 0303/4 - 14

Spindle Connector - 9pin clamp terminal Pin A Please ensure, that PE protective earth is connected at the mains side. The device must not be operated without properly connected PE! A Please ensure, that PE protective earth is connected at the spindle side as well as at the mains side. A Control wires. Mains cables and spindle cables should be installed separately. For wiring, the use of shielded cables is recommended. SFU 0303Mains connection - 3pin clamp terminal: Name

Open the catalog to page 14
SFU 0303/4 - 15

6.8 Desktop Version: Mains and Spindle Connection The connection with mains network is carried out with an IEC connector The device is equipped with a Thermo-Automatic Fuse for each prong. They can be reset after tripping by pressing down the button The spindle connection is realized on custom order and can be realized accordingly Spindle connection Automatic Fuse Sicherungsa Spindle Interface Backside SFU0303-Desktop equipped with a 7pin circular spindle connection …when it comes to quality! BMR GmbH

Open the catalog to page 15
SFU 0303/4 - 16

7pin female Binder Series 693 or Amphenol C16-1 Spindle Connection 13pin female Binder Series 694

Open the catalog to page 16
SFU 0303/4 - 17

6.% USB-Connection For easy connection and communication, the device is equipped with a USB interface. At the version SSE it is located at the bottom side as USB Mini AB. At the 19" and Desktop devices, it is found at the front panel directly below the display. This interface shares the functionality with the USB Interface. For that reason it can be used alternatively, only …when it comes to quality! BMR GmbH

Open the catalog to page 17

All BMR GmbH catalogs and technical brochures

  1. Catalogue

    52 Pages

  2. SFU 0102

    28 Pages

  3. SFU 400

    15 Pages

  4. SFU 0303

    56 Pages

  5. SFU 0103/0203

    30 Pages

  6. SFU 0303

    56 Pages

  7. SFU0300

    24 Pages

  8. DressView

    32 Pages

  9. Folnet P

    8 Pages

  10. Folnet3-NT

    8 Pages

  11. Folnet 1 NT

    8 Pages

  12. Folnet 1

    8 Pages

  13. Folinv 12/3

    4 Pages

  14. SFU 0401

    10 Pages

  15. SFU 0302 19”

    28 Pages

  16. SFU 0302 SSE

    30 Pages

  17. SFU 0101/0201

    17 Pages

  18. SFU 0100

    2 Pages

  19. SFU 0303/2

    50 Pages

  20. SFU0052

    12 Pages

  21. SFU 0200/1

    24 Pages

  22. SFU 0103

    24 Pages

  23. SFU 0156

    20 Pages

  24. SFU 0150

    20 Pages

  25. SFU 0102/0202

    28 Pages

  26. KG-T 500

    20 Pages