RS232 Control Commands - 1

Documentation:Communication commands for serial controlling Valid for the following types SFU0051 SFU0151, SFU0152, SFU0154, SFU0156 SFU0200 SFU0300 SFU0303 RS232 Interface Setting: 115kB, 8 data, no parity, 1 stop bit SFU0102, SFU0202 SFU0302 RS232 Interface Setting: 9,6kB, 8 data, no parity, 1 stop bit

Open the catalog to page 1
RS232 Control Commands - 2

Communication commands for serial controlling 1-Byte-Commands in HEX Format: _________________________________________________________________________ Command: Start Transmit: 0xE4h 0xll Low Byte rpm 0xhh High Byte rpm _________________________________________________________________________ Command: Stop Transmit: 0xE5h 0xll Low Byte rpm 0xhh High Byte rpm _________________________________________________________________________ Request: duty rpm (*10) Send set value of duty speed Transmit: Low Byte duty rpm High Byte duty rpm To get the real value, the received value has to be multiplied...

Open the catalog to page 2
RS232 Control Commands - 3

SFU Communication commands for serial controlling GmbH Request: converter status 0xll Low Byte Status Word 0xhh High Byte Status Word Bits of the status word: reserved Status Start/Stop Status reserved Status Remote control on Status Real rpm reached (In case of using a hall sensor: real rpm = set value rpm Status Duty rpm reached (= Set Value of Duty Speed) Status Spindle Stop Status Undervoltage Status Overvoltage Status Varioload reached Status Error RS232 Interface Status Spindle not ready Status Converter not ready Status Overload Status Excess Temperature Converter Status...

Open the catalog to page 3
RS232 Control Commands - 4

Communication commands for serial controlling 3-Byte-Commands in HEX Format: _________________________________________________________________________ Command: Set duty rpm (= desired value / 10) Transmit: Low Byte duty rpm High Byte duty rpm Low Byte High Byte The desired set value has to be divided by 10 and then send to the converter for example, set rpm to 20.000: 20.000/10 = 2.000d = 07D0h => send "01 D0 07" _________________________________________________________________________ Command: Set Datapointer for reading a data variable Transmit: Low Byte Pointer High Byte Pointer Low Byte...

Open the catalog to page 4
RS232 Control Commands - 5

Communication commands for serial controlling List of the internal variables Variable

Open the catalog to page 5
RS232 Control Commands - 6

Communication commands for serial controlling e-mail: Info@bmr-gmbh.de Internet: www.bmr-gmbh.de Subject to technical alterations. 07. 10. 2013

Open the catalog to page 6

All BMR GmbH catalogs and technical brochures

  1. Catalogue

    52 Pages

  2. SFU 0102

    28 Pages

  3. SFU 400

    15 Pages

  4. SFU 0303

    56 Pages

  5. SFU 0103/0203

    30 Pages

  6. SFU 0303

    56 Pages

  7. SFU0300

    24 Pages

  8. DressView

    32 Pages

  9. Folnet P

    8 Pages

  10. Folnet3-NT

    8 Pages

  11. Folnet 1 NT

    8 Pages

  12. Folnet 1

    8 Pages

  13. Folinv 12/3

    4 Pages

  14. SFU 0401

    10 Pages

  15. SFU 0302 19”

    28 Pages

  16. SFU 0302 SSE

    30 Pages

  17. SFU 0101/0201

    17 Pages

  18. SFU 0100

    2 Pages

  19. SFU 0303/4

    48 Pages

  20. SFU 0303/2

    50 Pages

  21. SFU0052

    12 Pages

  22. SFU 0200/1

    24 Pages

  23. SFU 0103

    24 Pages

  24. SFU 0156

    20 Pages

  25. SFU 0150

    20 Pages

  26. SFU 0102/0202

    28 Pages

  27. KG-T 500

    20 Pages