1. Catalogs
  2. BMAir International BV
  3. Replacing filters instructions

Replacing filters instructions

Replacing filters instructions

Replacing filters instructions

Product catalog summary
Introduction
BMAir International B.V. emphasizes the importance of clean air as a fundamental right and provides detailed instructions for replacing filters in their systems.

Safety Precautions
Users are advised to wear protective gear, including overalls, gloves, respiratory protection, and protective glasses. Filters should not be touched directly to avoid leaks and reduced protection.

Filter Specifications and Usage
Combifilters with activated carbon are programmed for 520 hours of use, while asbestos filters last 960 hours. Filters must be disposed of according to environmental regulations. Only original BMAir filters should be used to ensure quality and avoid damage.

Filter Replacement Indicators
Filters need replacement when cabin measurements exceed limits, control system alerts, filter LEDs turn orange, operating hours exceed limits, or upon safety expert advice. The display in the cabin provides information on filter type and usage hours.

Filter Replacement Procedure
1. Wear prescribed PPE.
2. Open the system as per the manual.
3. Remove existing filters.
4. Check and replace damaged seals.
5. Inspect for unexpected dust.
6. Position new P1 filter before P3 or carbon filter.
7. Reset filter counters in the display.
8. Position filters as illustrated.
9. Close the system.
10. Dispose of contaminated filters properly.

Maintenance Recommendations
BMAir recommends using authorized service points for maintenance to ensure proper filter replacement and installation. Annual checks are advised to maintain certification, and custom programming of filter specifications is available.

Conclusion
This document provides essential guidelines for maintaining air quality through proper filter management in BMAir systems.
See more

Catalog excerpts

Replacing filters instructions-1

clean air is a undamental T right Replacing filters instructions

 Open the catalog to page 1
Replacing filters instructions-2

Please read these instructions carefully before replacing filters Please note filters which are tuned in to each other. Consult an expert on the appropriate filter type(s) applicable to the specific contamination. Carbon fi lters are provided with yellow seal tape. If this tape is not present, or broken, the carbon fi lter must not be used. Please note Combifilters with an activated carbon filter are programmed as standard with a theoretical usage time of 520 hours. Combifi lters Asbestos (article number ends with 020) are standard programmed with a theoretical usage time of 960 hours. Please...

 Open the catalog to page 2
Replacing filters instructions-3

When using original BMAir filters, the display in the cabin will automatically give a signal when the filter theoretically has to be replaced. To be alert to the level of hydrocarbons in the cabin, an extra sensor can be installed. It makes the operator aware of any hydrocarbons entering the cabin, so the filter can be replaced immediately. The machine operator or safety expert can easily see in the display which type of filter is installed and how many hours it's running via filter recognition. When one of the following events occur, we highly recommend replacing the filters: • the measurement...

 Open the catalog to page 3
Replacing filters instructions-4

Bliek 8 4941SG Raamsdonksveer | The Netherlands

 Open the catalog to page 4
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.