Catalog excerpts
Technical Data Automated BlowerDoor Measurement with TECTITE Express BlowerDoor Standard Capacity: Power supply: Measuring accuracy: 19 – 7,200 m³/h at 50 Pa 220 – 240 V, 50 Hz, nominal output < 600 W, max. power consumption 3.7 A With open fan, rings A – C (flow rate approx. 80 – 7,200 m³/h) ± 4 % of the mean. With rings D – E (flow rate approx. 19 – 80 m³/h) ± 5 % of the mean or ± 1.7 m³/h (the higher value is valid) With a measuring range of 19 to 7,200 m³/h, BlowerDoor Standard, one of the most successful airtightness Measurement Systems worldwide, is ideal for use in new buildings as well as during the rehabilitation of any residential or commercial building. If necessary, it can be expanded onto the BlowerDoor MultipleFan Measuring System. 5 – 2,300 m³/h at 50 Pa 220 – 240 V, 50 – 60 Hz, nominal output 240 W, max. power consumption 3.0 A With open fan, rings 1– 3 ±4 % of the mean or ± 1.7 m³/h (the higher value is valid). With ring 4 ± 4 % of the mean or ± 0.9 m³/h (the higher value is valid) Dimensions and weight (fan): Ø approx. 610 mm, approx. 15 kg Dimensions and weight (controller): L 410 × W 115 × D 90 mm, approx. 2 kg Mounting frame standard size: BlowerDoor MiniFan BlowerDoor Measuring Systems are universally applicable: With a measuring range of 5 to 2,300 m³/h, our compact BlowerDoor MiniFan System is perfect for use in individual apartments or very airtight or smaller buildings. BlowerDoor Standard Ø approx. 345 mm, approx. 2.7 kg L 220 × W 220 × D 90 mm, approx. 2 kg Dimensions from W 0.71 – 1.14 m to L 1.32 – 2.43 m, incl. lower and middle cross bars, weight approx. 7 kg, special dimensions on request BlowerDoor MiniFan Panel standard size: BlowerDoor panel with one opening and viewing window Digital pressure gauge DG-700 With 2 pressure channels and cruise control function Measuring range: -1,250 – +1,250 Pa Display resolution: 0.1 Pa Accuracy: ± 1 % of reading or ± 0.15 Pa (the higher value is valid) Auto-zeroing: At the start, and every 10 seconds Differential pressure display: Separate display of the two differential pressure channels Flow rate display: Compatible with Minneapolis BlowerDoor fans model 4 (BlowerDoor Standard), model 3, DuctBlaster Units: m³/h, l/s Averaging: 1 second, 5 seconds, 10 seconds, or long-term mean Operating temperature: 0 – 50°C LCD Display: Large, easy-to-read display: L 80 × W 30 mm incl. display illumination Batteries: 6 AA (optional power supply) Operating time: Approx. 100 hours Weight: Approx. 470 g Dimensions: L 195 × W 102 × D 32 mm Output: Serial data output (RS232), mini-USB Cruise control function: Automatic speed control of BlowerDoor fan for one-point test without a laptop (0/25/50/75 Pa) Laptop-controlled functions: Automated/semi-automated/ manual BlowerDoor measurement (Test Standard EN 13829) Dimensions: L 70 × W 48 × D 25 mm Weight: 57 g Radio Protocol: IEEE 802.11b compatible RF Output Power (Typical): +18 dBm RF Operating Frequency: 2.4 – 2.497 GHz Supported Data Rates: 11/5.5/2/1 Mbps (802.11b) Operating Temperature: 0 – 50°C Certifications and Compliance: WiFi, FCC, IC, ETSI, RoHS, CE Power Source: Connection to the Digital Gauge DG-700 (+6 – +12 V DC at 250 mA Nominal) Battery Life of DG-700 when connected with WiFi-Link: 20 – 30 hours continuous depending on digital gauge Wireless connection modes: Access point or routersupported Software TECTITE Express (Version 4.1 and reference guide available in EN/DE/FR) Automated/semi-automated/manual BlowerDoor test optional with WiFi, incl. Test Report (Test Standard EN 13829) System requirements: WIN XP or up Shipment includes Minneapolis BlowerDoor Standard: BlowerDoor fan with flow rings A – E / Minneapolis BlowerDoor MiniFan: Handy BlowerDoor fan (DuctBlaster) with flow rings 1 – 4 incl. fan cover, BlowerDoor panel (standard size), digital pressure gauge DG-700 with cruise control function and transport bag, fan speed controller (220 – 240 V) incl. gauge board, reference guide, software TECTITE Express 4.1, tube set, calibration certificate for the DG-700 (24 measuring points) and for the DuctBlaster fan (5 measuring points) packed in a robust transport bag / BlowerDoor mounting frame (standard size) incl. transport bag BlowerDoor MiniFan WiFi (optional): See BlowerDoor MiniFan, plus WiFi-Link Guarantee period: 4 years from purchase date © BlowerDoor GmbH / February 2016 accessory bag incl. fan cover, BlowerDoor panel (standard size), digital pressure gauge DG-700 with cruise control function and transport bag, fan speed controller (220 – 240 V) incl. gauge board, reference guide, software TECTITE Express 4.1, tube set, calibration certificate for the DG-700 (24 measuring points) and for the BlowerDoor fan (6 measuring points) / BlowerDoor mounting frame (standard size) incl. transport bag BlowerDoor Standard WiFi (optional): See BlowerDoor Standard, plus WiFi-Link With the DG-700 high precision pressure gauge and the TECTITE Express software included in the package, you can conduct highly accurate automated BlowerDoor tests in accordance with European Standard EN 13829 via a laptop computer. When performing quality assurance tests, the BlowerDoor fan is controlled directly from the DG-700 digital pressure gauge and a one-point test (without a laptop) is conducted at 50 Pascal to detect leakages. BlowerDoor WiFi (optional) additionally allows you
Open the catalog to page 1BlowerDoor test according to European Standard EN 13829 The standard-compliant measuring series is computer-controlled from a laptop with the new software TECTITE Express 4.1. If desired, the data is transferred from the pressure gauge to the laptop wirelessly through WiFi-Link. The test sequence can be controlled individually and the current measuring values are displayed on the monitor. All collected data is fed into the standard-compliant BlowerDoor test report for evaluation and documentation. This report contains queries and evaluations in accordance with European Standard EN 13829....
Open the catalog to page 2All BLOWERDOOR catalogs and technical brochures
-
FlowBlaster
4 Pages
-
Bau.Tools BlowerDoor
2 Pages
-
FireProtection
2 Pages
-
BlowerDoor MultipleFan
4 Pages