1. Catalogs
  2. Bloom Engineering
  3. 1150 SERIES ULTRA3 LOW NOX TM LUMIFLAME REGENERATIVE BURNER

1150 SERIES ULTRA3 LOW NOX TM LUMIFLAME REGENERATIVE BURNER

1150 SERIES ULTRA3 LOW NOX TM LUMIFLAME REGENERATIVE BURNER

1150 SERIES ULTRA3 LOW NOX TM LUMIFLAME REGENERATIVE BURNER

Product catalog summary
Overview: The document provides technical specifications and guidelines for the 1150 Series Ultra3 Low NOx Lumiflame Regenerative Burner, designed for aluminum applications. It emphasizes the importance of adhering to safety standards to prevent hazards.
Specifications: The burner dimensions vary by model, with detailed measurements provided for each. The document lists dimensions from the centerline of the burner to the bottom of the case, excluding support structures. It also includes media case dimensions and approximate weights for different models.
Compressed Air Consumption: Models 025 to 150 require 1 cfm per actuator, while models 200 to 250 require 2.5 cfm. Air quality must meet ISO standard 8573.1, with specific limits on particle size, dew point, and oil content.
Flame Information: The flame envelope must remain unobstructed to maintain low NOx emissions. Flame dimensions are provided for natural gas fuel with 10% excess air, noting that oil firing results in longer flames.
Installation and Safety: The document repeatedly cautions against improper use of combustion equipment, urging compliance with national safety standards and insurance recommendations. It also notes that modifications to the burner can affect NOx emissions.
See more

Catalog excerpts

1150 SERIES ULTRA3 LOW NOX TM LUMIFLAME REGENERATIVE BURNER-1

1/10 1150 SERIES ULTRA3 LOW NOXTM LUMIFLAME REGENERATIVE BURNER DIMENSIONS - ALUMINUM APPLICATIONS Catalog No. 1150- inches m 025 050 075 100 150 200 250 48.13 53.88 60.00 64.88 72.13 78.88 85.00 1.22 1.37 1.52 1.65 1.83 2.00 2.16 “D” Dimension from centerline of burner to bottom of case. Not including support structure as shown on drawing. MANUFACTURED UNDER U.S. PATENT NO. 5,180,300 CAUTION: The improper use of combustion equipment can result in a condition hazardous to people and property. Users are urged to comply with National Safety Standards and/or Insurance Underwriters recommendations © Bloom Engineering Co 2009 1

 Open the catalog to page 1
1150 SERIES ULTRA3 LOW NOX TM LUMIFLAME REGENERATIVE BURNER-2

1/10 1150 SERIES ULTRA3 LOW NOXTM LUMIFLAME REGENERATIVE BURNER ALUMINUM APPLICATIONS Standard 10° Down Note: Secondary air and exhaust connections are 125# flanges standard. RPM flanges optional. NOTE: GENERAL DIMENSION INFORMATION. SEE BLOOM REPRESENTATIVE FOR CERTIFIED DIMENSIONS FOR CONSTRUCTION. CAUTION: The improper use of combustion equipment can result in a condition hazardous to people and property. Users are urged to comply with National Safety Standards and/or Insurance Underwriters recommendations. © Bloom Engineering Co 2009 2

 Open the catalog to page 2
1150 SERIES ULTRA3 LOW NOX TM LUMIFLAME REGENERATIVE BURNER-5

1/10 1150 SERIES ULTRA3 LOW NOXTM LUMIFLAME REGENERATIVE BURNER COMPRESSED AIR CONSUMPTION 025 to 150 = 1 cfm/actuator design 200 to 250 = 2.5 cfm/actuator design Air quality “reasonably clean and dry and to a quality class 4.5.5 (according to ISO standard 8573.1)”. This implies 25 micron maximum particle size, 7°C dew point maximum (or lower than ambient temperature below 7°C) and 25 mg/cubic meter maximum oil content. APPROXIMATE BURNER WEIGHTS Total Weight Catalog No. 1150- Burner Head Media Case w/ Media Media lbs lbs kg lbs kg lbs kg 2110 3600 4830 6410 9815 11805 13980 025 050 075 100 150...

 Open the catalog to page 5
1150 SERIES ULTRA3 LOW NOX TM LUMIFLAME REGENERATIVE BURNER-7

1/10 1150 SERIES ULTRA3 LOW NOXTM LUMIFLAME REGENERATIVE BURNER TYPICAL PORT/INSTALLATION CAUTION: The improper use of combustion equipment can result in a condition hazardous to people and property. Users are urged to comply with National Safety Standards and/or Insurance Underwriters recommendations. © Bloom Engineering Co 2009 7

 Open the catalog to page 7

All Bloom Engineering catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.