Catalog excerpts
block-trafo.de ENG 2009/2010 EDITION 1 The perfect power supply system www.pv400.de programmable energy-efficient Powerful comprehensive communicative
Open the catalog to page 1Made in Germany the power to supply the power to supply BLOCK – one of the best in the world where power supply interfacing is concerned. This multinational organisation has consciously chosen to keep development and production in-house so that it can provide a rapid and fl exible response to customer requirements. EMC tests, environmental simulations and device safety inspections can also be carried out in-house and entirely independently in the company‘s BLOCKLAB test laboratory. Development and production based in Germany but serving the entire world BLOCK‘s world-famous blue miniature...
Open the catalog to page 2Connector for signal contacts on the front panel of all PowerVision components with integrated monitoring unit. PV-CON Windows-compatible software for the confi guration and visualisation of all PowerVision components with integrated monitoring unit. Free download from www.PV400.de Software Accessories 1.8 m long adapter cable for RS-232 interface. Used to connect PowerVision components to controllers or PCs. PV-KOK2 Practical mounting trays with magnetic mount to cover openings in the tops of devices. They prevent cable residue falling into PowerVision components during installation. They...
Open the catalog to page 20PVSE 230 Technical data ECONOMY PVSE 230/24-3 PVSE 230/24-5 PVSE 230/24-10 PVSE 230/48-5 72 Watt 120 Watt 240 Watt 240 Watt Safety standards EN 61204-3 (product standard) Approvals UL UL/CSA 60950 recognised, UL 508 listed/CSA 22.2 No. 107.1 3rd Ed. listed Environment Ambient temperature –10° C to +70° C derating, 2.5 %/K > +55° C –10° C to +70° C derating, 2.5 %/K > +55° C Storage temperature –25° C to +85° C Cooling AN (natural air convection cooling) Allowable humidity 30 to 85 % relative humidity, no dew Safety and protection HV test voltage 4.2 kVdc Conductors Use copper conductors...
Open the catalog to page 23PVSE 400 Technical data PVSB 400 Technical data BASIC PVSB 400/24-10 PVSB 400/24-20 PVSB 400/24-40 240 Watt 480 Watt 960 Watt Safety standards Safety EN 60950, UL 60950, UL 508 EMV EN 61204-3 (product standard) Approvals UL UL/CSA 60950 recognised UL 508 listed/CSA 22.2 No. 107.1 3rd Ed. listed Environment Ambient temperature –10° C to +70° C, Derating –3 %/K > +50° C –10° C to +55° C, Derating –5 %/K > +45° C 400 to 500 Vac, Derating –0,5 Adc/10 Vac > 440 Vac Storage temperature –25° C to +85° C Cooling AN (natural air convection cooling) Allowable humidity 30 to 85 % relative humidity, no...
Open the catalog to page 24PVSL 400 Technical data PVFE 24 Technical data ECONOMY PVFE 24/24-12 PVFE 24/24-20 PVFE 24/24-24 PVFE 24/24-40 Electronic fuse with two channels for mounting on DIN 35 mm rail Electronic fuse with four channels for mounting on DIN 35 mm rail Safety standards Safety EN 60950, UL 508 EMC EN 61000-6-2 and EN 61000-6-3 (generic standard) Approvals UL UL 60950, UL 508 Environment Ambient temperature -10 °C to +60 °C Storage temperature -25 °C to +85 °C Cooling Natural air convection cooling Allowable humidity Safety and protection HV test voltage Construction Protection index IP 20 (to EN 60529)...
Open the catalog to page 25PVUA 24/24-10 PVUA 24/24-20 Management Module for accumulators for mounting DIN 35 rail Standards Safety EN 60950, UL 60950, UL 508 EMC EN 61000-6-2 and EN 61000-6-3 (generic standard) Approvals UL (pending) UL/CSA 60950 recognised UL 508 listed Environment Ambient temperature –10° C to +60° C Storage temperature –25° C to +85° C Cooling Natural air convection cooling Allowable humidity 30 to 85% relative humidity, no dew Safety and protection HV test voltage 500 Vdc (clamps to case) Type enclosed for installation in switching cabinet Protection index IP 20 (to EN 60529) Safety extra-low...
Open the catalog to page 26PVA 24 Technical data PVA 24/3,2Ah PVA 24/7Ah PVA 24/12Ah PVA 24 are maintenance-free lead gel rechargeable batteries for use with PVUA 24 General data Ambient temperature –10° C to +40° C Storage –25° C to +50° C Protection index IP 20 Safety class III Safety Batteries VdS inspected Service Life 5 years at 20° C, 4 years at 30° C, 2 years at 40° C Electrical data Nominal voltage 24 Vdc Nominal capacity 3.2 Ah 7 Ah 12 Ah Max. loading current 0.8 A 1.8 A 3 A End-of-charge voltage (at 25 °C) 27 Vdc Typ. buffer time at 10 A current requirement 6 min 20 min 46 min Typ. buffer time at 20 A...
Open the catalog to page 27BLOCK Transformatoren-Elektronik GmbH Max-Planck-Straße 36–46 • 27283 Verden • Germany Phone +49 4231 678-0 • Fax +49 4231 678-177 info@block-trafo.de • www.block-trafo.de Subject to change without notice Subsidiaries Belgium BLOCK Belgium BVBA Nieuwstraat 2 3200 Aarschot Phone: +32 1669-6945 Fax: +32 1669-7972 www.block-trafo.de georges.claes@block-trafo.de United Kingdom BLOCK UK LTD. 24 Bentalls Centre Colchester Road Heybridge Maldon Essex CM9 4GD Phone: +44 1621 85-0666 Fax: +44 1621 85-0711 www.blockuk.co.uk info@blockuk.co.uk USA BLOCK USA L.P. 820 Greenbrier Circle Suite 25...
Open the catalog to page 29All Block Transformatoren-Elektronik catalogs and technical brochures
-
STEU
9 Pages
-
LR3 400
13 Pages
-
SFA 400
4 Pages
-
Harmonic filter HFM-FB 400
5 Pages
-
TT3 NEO
4 Pages
-
RAILWAY TECHNOLOGY
6 Pages
-
DETUNED REACTORS DR3
6 Pages
-
BLOCK POWER SUPPLIES
84 Pages
-
Product News Harmonic Filter
4 Pages
-
EFFICIENCY
12 Pages
-
FAIL-SAFE transformer
4 Pages
-
PLED - LED Driver
6 Pages
-
The actual catalogue 1 Transformers
306 Pages
-
Harmonic Filter
4 Pages
-
BLOCK PARTS
12 Pages
-
BLOCK DIRECT
92 Pages
-
Power supplies
64 Pages
-
LR3 Reactors Brochure
2 Pages
-
BLOCK power supply
8 Pages
-
Components liquid cooled
12 Pages
-
Enclosures from BLOCK
3 Pages
-
PEL Power Supply
4 Pages
-
BLOCK Savergy brochure
7 Pages
Archived catalogs
-
Product News Harmonic Filter
4 Pages
-
HFM Harmonic Filter Modules
4 Pages