Harmonic filter HFM-FB 400
1 /5Pages

Harmonic filter HFM-FB 400

Harmonic filter HFM-FB 400
1 /5Pages

Catalog excerpts

Harmonic filter HFM-FB 400-1

3 Reactors / EMI filters Harmonic filters Harmonic filter HFM-FB 400 O BLOCK Website General Data Rated voltage 3 x 400 - 3 x 480 Vac Rated current 3 x 10.00 - 3 x 433.00 A 7 % typ. at nominal load Load rated capacity 5 - 250 kW Insulation class F Ambient temperature -10 °C to +40 °C Degree of protection IP 00 SCCR 100 kA [without preliminary fuse] Advantages Sinusoidal current consumption from the main in devices with uncontrolled B6U diode rectifiers or controlled B6C thyristor bridges Compliance with EN 61000-3-2, EN 61000-3-12 Support in the compliance with IEEE 519, D-A-CH-CZ Cos(phi)>0.95 at rated current Hardly any intermediate circuit voltage dip by comparison with a 4 % uK line reactor Use of the HFM as a central sum filter for multiple converters possible Applications Harmonic filter module to ensure sinusoidal main currents, reduction of main harmonic currents, increase in system service life and system reliability and compliance with power quality standards such as IEEE 519, TEC 61000-3-2, IEC 61000-3-12. Harmonic filter in accordance with UL 506, CSA 22.2

 Open the catalog to page 1
Harmonic filter HFM-FB 400-2

Reactors / EMI filters Harmonic filters BLDCKE5 Harmonic filter HFM-FB 400 O BLOCK Website Operating data Rated voltage Rated current Voltage range Rated frequency THD-I Rated load power* Description of the load Overrating Capacity 7 % typ at nominal load 7 % typ at nominal load 7 % typ at nominal load 7 % typ at nominal load 7 % typ at nominal load 7 % typ at nominal load Balanced load by inverter Balanced load by inverter Balanced load by inverter Balanced load by inverter Balanced load by inverter Balanced load by inverter cURus cURus cURus cURus cURus cURus...

 Open the catalog to page 2
Harmonic filter HFM-FB 400-3

Reactors / EMI filters Harmonic filters Harmonic filter HFM-FB 400 O BLOCK Website TypOperating data HFM-FB 70-400 Rated voltage Rated current Voltage range Rated frequency THD-I Rated load power* Description of the load Overrating Capacity Approvals Approvals Environment Ambient temperature MTBF 0 50 °C/500 V (Mil-HB-217F) Safety and protection Type Insulation class Protection index Safety class SCCR Notes Order numbers Order Number 7 % typ at nominal load 7 % typ at nominal load 7 % typ at nominal load 7 % typ at nominal load 7 % typ at nominal load 7 % typ at nominal load...

 Open the catalog to page 3
Harmonic filter HFM-FB 400-4

Reactors / EMI filters Harmonic filters BLDCKE5 Harmonic filter HFM-FB 400 O BLOCK Website Operating data Rated voltage Rated current Voltage range Rated frequency THD-I Rated load power* Description of the load Overrating Capacity 7 % typ at nominal load 7 % typ at nominal load 200.0 kW 250.0 kW Balanced load by inverter Balanced load by inverter 150 % for 60 sec. every 150 % for 60 sec. every 10 min. 10 min. cURus cURus Ambient temperature MTBF 0 50 °C/500 V (Mil-HB-217F) Safety and protection Type Insulation class Protection index Safety class SCCR Notes without condensation without...

 Open the catalog to page 4
Harmonic filter HFM-FB 400-5

Reactors / EMI filters Harmonic filters Harmonic filter HFM-FB 400 O BLOCK Website Mounting lugs Mounting lugs Mounting lugs Mounting lugs Mounting lugs Mounting lugs Mounting lugs Mounting lugs Mounting lugs Mounting lugs Mounting lugs Mounting lugs Mountinglugs Mountinglugs

 Open the catalog to page 5
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.