The RKD 20/2x24 is a mains transformer designed for high power efficiency with minimal size and weight. It features dual input and output voltages for flexible series or parallel connections, low no-load losses, and excellent temperature performance due to reduced magnetic leakage.

Advantages
  • Compact size with high power output
  • Lightweight design
  • Dual voltage inputs and outputs
  • Low no-load losses
  • Excellent temperature behavior
  • Low noise field

Applications
  • Voltage adjustment and electrical isolation
  • Isolating transformer for safe electrical separation
  • Safety isolating transformer for SELV and PELV circuits

Standards and Approvals
  • Complies with VDE 0570 Teil 2-1, DIN EN 61558-2-1, EN 61558-2-1, IEC 61558-2-1, UL 5085-1/-2, CSA 22.2 No.66
  • Approved by UL 5085-1/-2, CSA 22.2 No.66

Technical Specifications
  • Input: Rated input voltage of 2 x 115 Vac, frequency 50 - 60 Hz
  • Output: Rated output voltage of 2 x 24 Vac, power 20 VA, no-load voltage factor 1.29, no-load loss 0.33 W, efficiency 77%
  • Environment: Maximum ambient temperature 104.0 °F
  • Safety and Protection: Open type, insulation class VDE=B, UL=class 105, protection index IP 00, safety class II, non-short-circuit proof, test voltage 4,000 Vac, 50 Hz

Physical Characteristics
  • Major diameter: 2.36 inch
  • Outside diameter: 2.44 inch
  • Height without mounting: 1.22 inch
  • Weight: 0.71 lbs

Order Information
  • Order Number: RKD 20/2x24
  • Fixing method: Mounting kit, M4 bolt
  • Terminals: Connecting leads, 200 mm
See more

Catalog excerpts

RKD 20/2x24-1

Advantages Minimum size at high power Low weight Dual input and dual output voltage for series or parallel connection Minimal no-load losses Outstanding temperature behavior due to low magnetic leakage field Very low noise field Applications As a mains transformer for adjustment of the voltage and simple electrical isolation. As an isolating transformer for the safe electrical isolation of the input and output sides. The transformer may be used to set up protective separation as a protective measure in accordance with VDE 0100. As a safety isolating transformer for the safe electrical isolation of the input and output sides. The transformer is suitable for creating SELV and PELV circuits because of the limit on the output voltage. Sample application Mains transformer to: VDE 0570 Teil 2-1, DIN EN 61558-2-1, EN 61558-2-1, IEC 61558-2-1, UL 5085-1/-2, CSA 22.2 No.66

 Open the catalog to page 1
RKD 20/2x24-2

Rated input voltage Rated frequency Output Rated output voltage Power No-load voltage (app. x factor) No-load loss (typ.) Efficiency Terminal and mounting Fixing method Terminals Mounting kit, M4 bolt Connecting leads, 200 mm Major diameter Ø Outside diameter in the area of the wire lead Ø Height without mounting Weight 2.36 inch 2.44 inch 1.22 inch 0.71 lbs Standards Classification Mains transformer Approvals Approvals Environment Ambient temperature max. Safety and protection Type Insulation class Protection index Safety class (prepared) Short circuit strength Test voltage Open type VDE=B,...

 Open the catalog to page 2

All BLOCK Electronics (Kunshan) Co., Ltd catalogs and technical brochures

  1. BLOCK COMPACT

    80  Pages

  2. RTE 30/2x24

    2  Pages

  3. RTE 20/2x24

    2  Pages

  4. RKD 30/2x24

    2  Pages

  5. the big BLOCK

    719  Pages

  6. ALL ABOUT BLOCK

    17  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.