Catalog excerpts
Elevator Control Valves EN ISO 9001 The BLAIN EV program includes the widest range of options offered to the elevator industry for high performance passenger service. Easy to install, EV‘s are smooth, reliable and precise in operation throughout extreme load and temperature variations. Description Available port sizes are ¾", 1½", 2" and 2½" pipe threads, depending on flow. EV‘s start on less than minimum load and can be used for across the line or wye-delta starting. According to customers‘ information, valves are factory adjusted ready for operation and very simple to readjust if so desired. The patented up levelling system combined with compensated pilot control ensure stability of elevator operation and accuracy of stopping independent of wide temperature variations. EV valves include the following features essential to efficient installation and trouble free service: Simple Responsive Adjustment Temperature and Pressure Compensation Solenoid with Connecting Cables Pressure Gauge and Shut Off Cock Self Closing Manual Lowering Technical Data: Self Cleaning Pilot Line Filters Self Cleaning Main Line Filter (Z-T) Built-in Turbulence Suppressors 70 HRc Rockwell Hardened Bore Surfaces 100% Continuous Duty Solenoids 1½" & 2" EV Flow Range: l/min 10-125 (2-33 US gpm) 30-800 (8-211 US gpm) 500-1530 (132-404 US gpm) Pressure Range (valve): bar 8-100 (116-1450 psi) 8-100 (116-1450 psi) 8-68 (116-986 psi) Press. Range CSA (valve): bar 8-100 (116-1450 psi) 8-70 (116-1015 psi) 8-47 (116-682 psi) Burst Pressure Z: bar 575 (8339 psi) 505 (7324 psi) 340 (4931 psi) Pressure Drop P–Z: bar 6 (87 psi) at 125 l/min 4 (58 psi) at 800 l/min 4 (58 psi) at 1530 l/min Weight: kg 5 (11 lbs) 10 (22 lbs) 14 (31 lbs) Oil Viscosity: 25-60 cSt. at 40°C (104°F). Max. Oil Temperature: 70°C (158°F) Solenoids AC: 24 V/1.8 A, 42 V/1.0 A, 110 V/0.43 A, 230 V/0.18 A, 50/60 Hz. Insulation Class, AC and DC: IP 68 Solenoids DC: 12 V/2.0 A, 24 V/1.1 A, 42 V/0.5 A, 48 V/0.6 A, 80 V/0.3 A, 110 V/0.25 A, 196 V/0.14 A. 1½" & 2" EV Blain Hydraulics GmbH Pfaffenstrasse 1 74078 Heilbronn Germany Designer and Manufacturer of the highest quality control valves & safety components for hydraulic elevators GmbH
Open the catalog to page 1EV Control Valve Types Optional Equipment Emergency Power Solenoid CSA Solenoids Slack Rope Valve Main Shut-Off Valve Hand Pump High Pressure Switch Low Pressure Switch Pressure Compensated Down Auxiliary Down Up to 0.16 m/s (32 fpm). 1 Up Speed. Up Start is smooth and adjustable. Up Stop by de-energising the pump-motor. Up to 1.0 m/s (200 fpm). 1 Full Speed and 1 Levelling Speed. All down functions are smooth and adjustable. USA Patent No. 4,601,366 Pats & Pats Pend: France, Germany, Italy, Japan, Switzerland & U.K. Up to 0.16 m/s (32 fpm). 1 Up Speed. Up to 0.4 m/s (80 fpm) by...
Open the catalog to page 2Warning: Only qualified personnel should adjust or service valves. Unauthorised manipulation may result in injury, loss of life or damage to equipment. Prior to servicing internal parts, ensure that the electrical power is switched off, cylinder line is closed and residual pressure in the valve is reduced to zero. Adjustments UP Valves are already adjusted and tested. Check electrical operation before changing valve settings. Test that the correct solenoid is energised, by removing nut and raising solenoid slighty to feel pull. Nominal Settings: Adjustments 1 & 4 approx. level with flange...
Open the catalog to page 3Warning: Only qualified personnel should adjust or service valves. Unauthorised manipulation may result in injury, loss of life or damage to equipment. Prior to servicing internal parts, ensure that the electrical power is switched off, cylinder line is closed and residual pressure in the valve is reduced to zero. Adjustments DOWN Valves are already adjusted and tested. Check electrical operation before changing valve settings. Test that the correct solenoid is energised, by removing nut and raising solenoid slightly to feel pull. Nominal Settings: Adjustments 7 & 9 approx. level with flange...
Open the catalog to page 4Elevator Valves Control Elements Solenoid (Up Stop) U By Pass Valve Solenoid (Up Deceleration) V Check Valve Solenoid (Down Deceleration) W Levelling Valve (Up) Solenoid (Down Stop) X Full Speed Valve (Down) Manual Lowering Y Levelling Valve (Down) Relief Valve F Filter Hydraulic Circuit Adjustments DOWN 6 Down Acceleration 7 Down Full Speed 8 Down Deceleration 9 Down Levelling Speed Adjustments UP 1 By Pass 2 Up Acceleration 3 Up Deceleration 4 Up Levelling Speed 5 Up Stop Electrical Sequence BLAIN HYDRAULICS
Open the catalog to page 5EV Spare Parts List EV Pos. No. Item Solenoid Valves C+D A+B _ -MM -AD -[] Flow Valves Taper threads: Do not exceed 8 turns of piping into the valve connections. Flow Guide Selection Charts for Down Direction 2V" 50 l/min l/min l/min To order EV: Size (inch), valve type, state pump flow, empty car pressure (or flow guide size) and solenoid voltage. Example order: 2"EV100, 380l/min, 18bar (empty), 110 AC or 2"EV100/4/110AC BLAIN HYDRAULICS Designer and Manufacturer of High Quality Valves for Hydraulic Elevators Printed in Germany
Open the catalog to page 6All Blain Hydraulics GmbH catalogs and technical brochures
-
CX·EN·DH/DL
1 Pages
-
Slack Rope Valve KSB
1 Pages
-
Ball Valves BV
2 Pages
-
Down Valves HX MX
4 Pages
-
Elevator Control Valves KV
6 Pages
-
Elevator Control Valves EV 4