Overview: The document outlines the technical specifications and design features of the DP-200-4 model water-cooled shell and tube condensers and discharge gas desuperheaters. It covers construction details, safety standards, and performance data.
Specifications:
  • Heat-exchanger tubes are crafted from copper or copper-nickel for seawater resistance and feature a low-fouling profile.
  • Tubes are brazed into punched plates to prevent leaks.
  • The shell and punched plates are made from boiler plate P 265 GH.
  • Detachable end covers facilitate mechanical cleaning and are interchangeable.
  • Maximum allowable pressure is 33 bar on the refrigerant side and 10 bar on the coolant side.
  • Temperature range is -10°C to 120°C for refrigerants and -10°C to 95°C for coolants with antifreeze.
Design Features:
  • Plastic-coated punched plates and end covers are available for standard and seawater-resistant versions.
  • Offers various connection options for refrigerants and coolants, including Rotalock adapters and flanges.
  • Compatible with (H)CFC and HFC refrigerants, with special designs for refrigerants with a temperature glide over 2 K.
Performance Data:
  • Condenser performance is based on a discharge gas temperature of 90°C and a fouling factor of r=0.4x10-4 m2 K/W.
  • Condenser capacity can be calculated by adding refrigerating capacity and power input or using simplified methods with factors from provided graphs.
Special Versions and Accessories:
  • Seawater-resistant designs feature Cu-Ni tubes and plastic-coated end covers.
  • Includes adapters for pressure relief valves and various flange options.
  • Approved by international standards and bodies such as Bureau Veritas and Lloyd’s Register of Shipping.
Condenser Selection:
  • Selection can be made using performance tables or BITZER software for variable operating conditions.
  • Special notes highlight the need for sufficient capacity reserves for pull-down conditions or post-defrost periods.
See more

Catalog excerpts

Water cooled Condensers, Desuperheaters  DP-200-4-1

Wassergekuhlte Water cooled Condenseurs Desuperheaters Desurchauffeurs

 Open the catalog to page 1
Water cooled Condensers, Desuperheaters  DP-200-4-2

Wassergekühlte Bündelrohr-Verflüssiger und Druckgas-Enthitzer Water-cooled Shell and Tube Condensers and Discharge Gas Desuperheaters Condenseurs à eau multitubulaires et désurchauffeurs de gaz sous pression Die sicherheitstechnische Ausführung Abnahme entsprechend der EG-Druckgeräterichtlinie 97/23/EG Design safety Approval according to the EC Pressure Equipment Directive 97/23/EC Exécution sûreté Contrôle conforme à la Directive CE Equipements sous Pression 97/23/CE Konstruktions-Merkmale ❏ Wärmeübertrager-Rohre: aus Cu bzw. Cu-Ni (Seewasser beständige Ausführung) mit neu entwickelter Rohrgeometrie...

 Open the catalog to page 2
Water cooled Condensers, Desuperheaters  DP-200-4-3

Sonder-Ausführungen ❏ Seewasser beständige Ausführung: – Cu-Ni-Rohr, Umlenkdeckel Kunststoff beschichtet ❏ Umlenkdeckel Kunststoff beschichtet für Standard-Ausführung mit Cu-Rohren ❏ Befestigungs-Schienen oder Befestigungs-Platten (z.B. für Verdichter-Aufbau) ❏ Adapter zum Anschluss des Druckentlastungs-Ventils für alle Modelle ❏ Gewinde- bzw. Vorschweiß-Flansche ❏ Kältemittel- Ein- und Austritt mit verschiedenen Adapter- und Ventil-Kombinationen ❏ Abnahme entsprechend ausländischer Vorschriften und diversen Abnahmegesellschaften (z.B. Bureau Veritas, Germanischer Lloyd, Lloyd’s Register of Shipping)...

 Open the catalog to page 3
Water cooled Condensers, Desuperheaters  DP-200-4-4

zu ermitteln. Die am Verflussiger abzu- fuhrende Leistung kann auf zwei unter- schiedliche Arten berechnet werden: Condenser selection For condenser selection, it is first necessary to determine the condenser capacity Q. The power to be dissipated Le choix du condenseur est a faire avant de determiner la puissance de liquefaction Q. denseur peut etre determinee de 2 manie- Bei diesen Verfahren werden Kalteleis- dichters addiert (bzw. der Verdichter bei konnen den Verdichter-Prospekten oder der Software entnommen werden. Condenser capacity as a total of refrigerating capacity and power With this...

 Open the catalog to page 4
Water cooled Condensers, Desuperheaters  DP-200-4-5

Durchsatz Kuhlmedium Condenser capacity Coolant flow Pressure drop Quantite passee de fluide caloporteur Pressure drop Quantite passee Pressure drop Standard design Version standard Seewasser bestandige Ausfuhrung Seawater resistant design Version marine Vorlaufige Daten - Tentative data - Discharge gas temperature 90°C, fouling factor Donnees provisoires - valables pour les fluides frigorigenes R134a, R404A. Temperature de gaz au refoulement 90°C et facteur

 Open the catalog to page 5
Water cooled Condensers, Desuperheaters  DP-200-4-6

Maßzeichnungen Standard-Ausführung 2 5 1 1/4"-12 UNF 1 4 T Croquis cotés Version standard U 60 B Z 6 S D L F C E E1 K033N K073H K123H Dimensional drawings Standard design R1 Y G R 9 I X B1 H A1 2 W 5 1 1/4''-12 UNF 4 1 F OUT 4 Pass 18 9 Y R1 IN 7 S D E1 Z C E I G R H B1 U1 W 5 1 1/4"-12 UNF U2 U 42 45 F B 42 27,5 Z D 27,5 1 C1 T V A K1353T K1973T K2923T K3803T K4803T A1 L X 60 B U T L K203H K283H K373H K573H K813H K1053H V A 4 Pass E X E1 Y 6 8 S C R R1 13 250 18 H 280 A1 I 360 A 6 2 420 4 DP-200-4

 Open the catalog to page 6
Water cooled Condensers, Desuperheaters  DP-200-4-7

Standard design Version standard □ Fur Kunststoff beschichtete Umlenkdeckel □ For plastic coated reversing covers dimensions □ Pour couvercles deflecteur revetus d'une resine syn- gelten die MaBe der Seewasser-Ausfuhrung are equal to seawater resistant design thetique, memes dimensions que pour la version 4 Pressure gange connection 5 Connection for pressure relief valve internal thread %" -18 NPTF 1 Entree de fluide frigorigene 2 Sortie de fluide frigorigene 5 Raccord pour soupape de decharge filet interieur 3/8" -18 NPTF Kaltemittel-Anschlusse siehe Seite 10 Refrigerant connections see page...

 Open the catalog to page 7
Water cooled Condensers, Desuperheaters  DP-200-4-8

Maßzeichnungen Seewasser beständige Ausführung 4 1 U T Croquis cotés Version marine E B Z F 5 1 1/4"-12 UNF L 60 6 S D C 2 E1 K033NB K073HB Dimensional drawings Seawater resistant design R1 B1 H A1 2 W 4 3 T 5 1 1/4"-12 UNF 1 60 B U E Z OUT 4 Pass 6 IN Y S L C1 R E1 F D K123HB K203HB K283HB K373HB K573HB K813HB V A C I G 60 9 Y X 9 6 H/2 H B1 A1 W 4 42 27,5 27,5 60 B Z F OUT 4 Pass IN Y S R E1 42 3 U2 U 7 U1 1 L T 5 1 1/4"-12 UNF C1 2 D K1053HB K1353TB K1973TB K2923TB V A C I G 18 R1 X R1 13 6 E X I G E 18 H B1 A1 U1 5 1 1/4"-12 UNF U2 U 42 42 27,5 3 45 B Z F D 27,5 1 C1 T W 4 Pass L K3803TB...

 Open the catalog to page 8
Water cooled Condensers, Desuperheaters  DP-200-4-9

Abmessungen Dimensions Dimensions Seewasser bestandige Ausfuhrung Seawater resistant design Version marine 3 Alternative refrigerant outlet 4 Pressure gange connection 5 Connection for pressure relief valve internal thread %" -18 NPTF 1 Entree de fluide frigorigene 2 Sortie de fluido frigorigene 3 Sortie alternative de fluide frigorigene 5 Raccord pour soupape de decharge filet interieur 3/8" -18 NPTF Kaltemittel-Anschlusse siehe Seite 10 Refrigerant connections see page 10 Raccords de fluide frigorigene voir page 10 Kuhlmedium-Anschlusse siehe Seite 11 Coolant connections see page 11 Raccords...

 Open the catalog to page 9
Water cooled Condensers, Desuperheaters  DP-200-4-10

Technische Daten Technical data Caracteristique techniques © At 20°C liquid temperature and 90% receiver © A une temperature de liquide de 20°C et pour une © Andere Anschlusse siehe Preisliste © Alternativer Kaltemittel-Austritt (unten) bei Seewasser bestandiger Ausfuhrung ab Typ K123HB - siehe nachfolgende Tabelle. © Other connections see Price List © Alternative refrigerant outlet (bottom) with sea- water resistant design from Type K123HB - see also the following table. © Autre raccords voir Tarif © Sortie alternative de fluide frigorigene (en bas) pour execution eau de mer a partir du type...

 Open the catalog to page 10
Water cooled Condensers, Desuperheaters  DP-200-4-11

Ku h I mediu m- Ansch I iisse Fixing rails Raccordements de la fluide caloporteur Eirrtritt Austritt Entree Sortie Eintritt Austritt Entree Sortie Schienen Rails Rails Unten Oben Fur Verdichter Pour compresseur Alle Gewinde sind Innengewinde All threads are internal threads Fixing plates Tous filets sont interieurs © Pour brides a souder a collerette DIN 2633, ND 10/16 ou pour brides avisser DIN 2566, ND 10/16