1. Catalogs
  2. Bituo Technik
  3. SDM01_Datasheet

SDM01_Datasheet

SDM01_Datasheet
1 / 13 PagesView full catalog

SDM01_Datasheet

Product catalog summary
Product Description
The SDM01 is a smart energy monitor designed for professional 3-phase energy measurement. It features a compact 18mm-width monitor for DIN rail installation and three split-core current transformers (CTs). It provides real-time monitoring of voltage, current, power, and energy data with both wireless and wired communication options.

Product Highlights
  • Bi-directional measurement for both consumption and generation.
  • Real-time monitoring of key electrical data.
  • Easy installation with compact design.
  • Versatile communication options including Wi-Fi, Zigbee, BLE, and Modbus.
  • Local automation capabilities for dynamic load balancing and zero export for home energy management systems.

Typical Applications
  • Home energy monitoring and metering.
  • Energy usage monitoring for small businesses and commercial buildings.
  • Industry energy efficiency projects.
  • Dynamic load balancing and solar generation management.

Parts Description
  • Connectors for voltage and current transformer connections.
  • RS485 communication connector for specific versions.
  • Reset button and status/alarm LEDs for operational feedback.
  • Product QR code and model information for identification.
  • DIN rail mounting and calibration ID for accuracy.

Technical Specifications
  • Rated operating voltage: 220~240 VAC phase to neutral, 380~415 VAC phase to phase.
  • Max current: 80A / 120A / 200A.
  • Over-voltage category: III, Protection degree: IP20.
  • Measurement tolerance standards: IEC 61557-12.
  • Operating temperature: -25~70 ℃.
  • Integrated communication options: Wi-Fi, Zigbee, Modbus.

Ordering Information
  • Various models available with different communication options (Wi-Fi, Modbus, Zigbee).
  • Tuya and customer-specific cloud integrations supported.

Installation Notice
  • Installation should be performed by qualified professionals only.
  • Ensure compliance with local, regional, and national regulations.
  • Install inside electrical panels to prevent unauthorized access.

Safety Warnings
  • Risk of electric shock, explosion, or arc flash if not handled properly.
  • Fire hazard if not associated with appropriate protection systems.
  • Risk of equipment damage if installation instructions are not followed.

Wiring Scheme
  • Ensure voltage and current measurements match for accurate monitoring.
  • Not suitable for IT systems.

Mechanical Outline
  • Dimensions provided for monitoring module and split-core CTs.

Disclaimer
Information is subject to change without notice. BITUOTECHNIK is not liable for any errors or damages arising from the use of this document.
See more

Catalog excerpts

SDM01_Datasheet-1

SDM01 Smart Energy Monitors with Split-core Current Transformers SDM01 Smart Energy Monitors with Split-core Current Transformers Datasheet Product Description SDM01 smart energy monitor is a monitoring device that consists of a 18mm-width (1MW) monitor installed at DIN rail and three split-core current transformers (CTs). Functioning as a professional 3-phase energy meter, it accurately measures real-time voltage, current, power and energy data, with wireless and/or wired communication options available for data transmission. Bi-directional measurement: Measure power and energy flow in both consumption and generation. Real-time monitoring: Monitor key electrical data like Voltage, Current, and Power in real time. Easy installation: Monitoring module requiring only 1MW at DIN rail and associating with compact split-core CTs Versatile communication: A wide range of communication options including Wi-Fi, Zigbee, BLE, Modbus etc. Local Automation: Enable local UDP broadcasting and HTTP requests, ideal for DLB1) and zero export for HEMS2) Real-time home energy monitoring and metering Energy-usage monitoring for small business3) Electrical monitoring for commercial buildings4) and infrastructures Electrical monitoring for industry energy efficiency projects Dynamic load balancing and zero export to grid with solar generation5) 1) DLB: Dynamic Load Balancing 2) HEMS: Home Energy Management System 3) Small business: Café, restaurant, shop, renting apartment etc. 4) Commercial buildings: office, hotel, shopping malls etc. 5) In addition to whole-home energy monitoring when being installed at the main incoming circuit, the real-time monitoring of bi-directional power flow can provide input for DLB and minimizing grid export from solar generation Smart Energy Monitors

 Open the catalog to page 1
SDM01_Datasheet-2

SDM01 Smart Energy Monitors with Split-core Current Transformers Split-core CTs (Detection module) # (Monitoring module) The monitor module powers itself and measures voltage via four cables for take-offs connection The Red(+)/Black(-) wires of CT(X), CT(Y), CT(Z) must match the +/- poles of transformer connection Only for product versions with RS485 communication function Reset button Reset button Press the button 3~5 seconds to enter the pairing mode ON, normal using, connect to cloud Flashing at 2Hz, in pairing mode Flashing at 0.5Hz, paired, searching for cloud Flashing at 0.25Hz, self-checking...

 Open the catalog to page 2
SDM01_Datasheet-3

SDM01 Smart Energy Monitors with Split-core Current Transformers Technical Specification # Technical specification Rated operating voltage Un 220~240 VAC phase to neutral, 50/60 Hz 380~415 VAC phase to phase, 50/60 Hz1) Over-voltage category Rated insolating voltage Ui Rated impulse withstand voltage Uimp Pollution degree Protection degree Reference standard for measurement tolerance: Current: Class 1 Active power: Class 1 Forward active energy: Class 1 Power consumption Normal using:1.5 Watt Pairing mode:2.0 Watt Rated operating temperature Size: Height x Width x Depth Monitoring Module: 113.7mm...

 Open the catalog to page 3
SDM01_Datasheet-4

SDM01 Smart Energy Monitors with Split-core Current Transformers Ordering Information Product part 1 – Combined Wi-Fi and Modbus communication # Ordering number SDM01, 3×80A SCT-A/Φ10.2, 3P+N, Wi-Fi+Modbus, Tuya Cloud Integration1) + Modbus Slave 3P+N, Wi-Fi+Modbus, Tuya Cloud Integration1) + Modbus Slave 3 3P+N, Wi-Fi+Modbus, Tuya Cloud Integration1) + Modbus Slave 4 3P+N, Wi-Fi+Modbus, Customer-specific Cloud Integration2) + Modbus Slave 5 3P+N, Wi-Fi+Modbus, Customer-specific Cloud Integration2) + Modbus Slave 6 3P+N, Wi-Fi+Modbus, Customer-specific Cloud Integration2) + Modbus Slave Remark:...

 Open the catalog to page 4
SDM01_Datasheet-5

SDM01 Smart Energy Monitors with Split-core Current Transformers Ordering Information Product part 2 –Wi-Fi communication # Ordering number Remark: 1) Tuya CB3S Wi-Fi & Bluetooth module (BK7231N SoC) is used for product versions connecting to Tuya cloud. Smart Life- an APP owned by Tuya Smart- can be used to access the device. Also, Tuya Integration at Home Assistant OS and Tuya Smart API can be used to access the device indirectly via Tuya Smart cloud. 2) ESP8685-WROOM-01 Wi-Fi & Bluetooth module (ESP8685H4 SoC) is used for product versions supporting customer-specific cloud integration. An...

 Open the catalog to page 5
SDM01_Datasheet-6

SDM01 Smart Energy Monitors with Split-core Current Transformers Ordering Information Product part 3 –Zigbee communication # Ordering number 3P+N, Zigbee, Tuya Zigbee Cluster1) 3 3P+N, Zigbee, Tuya Zigbee Cluster1) 4 3P+N, Zigbee, Standard Zigbee Cluster 5 3P+N, Zigbee, Standard Zigbee Cluster 6 3P+N, Zigbee, Standard Zigbee Cluster Remark: 1) Tuya ZS3L Zigbee module (EFR32MG21 SoC) with Tuya’s proprietary Zigbee clusters/attributes is used in the device. In addition to be connected by Tuya Zigbee gateway, the devices can be identified by universal Zigbee coordinators for Zigbee2Mqtt integration....

 Open the catalog to page 6
SDM01_Datasheet-7

SDM01 Smart Energy Monitors with Split-core Current Transformers Ordering Information Product part 4 –Modbus communication # Ordering number Smart Energy Monitors

 Open the catalog to page 7
SDM01_Datasheet-8

SDM01 Smart Energy Monitors with Split-core Current Transformers Installation Notice Please note before starting Installation  SDM01 should be installed, operated, serviced and maintained ONLY by qualified professionals. Qualified professionals refer to those who have the skills, license and knowledge related to the manufacture, operation and installation of electrical equipment. They are trained to detect and avoid risks. SDM01 should not be installed if, while unpacking, any damage is observed. SDM01 must be installed inside electrical panels or switchboards, behind a door or plate, so that...

 Open the catalog to page 8
SDM01_Datasheet-9

SDM01 Smart Energy Monitors with Split-core Current Transformers HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH  SDM01 should be installed, operated, serviced and maintained ONLY by qualified professionals. Apply appropriate personal protective equipment (PPE) and follow safe electrical work practices. See NFPA 70E, CSA Z462, DL/T 320 or local equivalent. Turn off all power supply sources before installing and during maintenance of this equipment. Always use a properly rated voltage sensing device to confirm power is off. Do not use a SDM01 for voltage testing purposes. A Voltage Tester must...

 Open the catalog to page 9

All Bituo Technik catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.