BRCS01C AC/DC Residual Current Sensor - Type-A 30 mA and/or DC 6 mA BRCS01C Residual Current Sensor for Charging Equipment of Electric Vehicles - 5V DC or 12V DC interfaces available to meet different design practices Two fault signal pins for solely DC 6mA and Type-A 30mA +DC 6mA alarming Cost-effective solution of built-in residual current device for AC EV charger Fast response time facilitating a broad selection of switching devices Compact design with 17mm through-hole for charging cable up to 3P+N 32A

Open the catalog to page 1
BRCS01C_Datasheet - 2

BRCS01C AC/DC Residual Current Sensor - Type-A 30 mA and/or DC 6 mA Technical Specification

Open the catalog to page 2
BRCS01C_Datasheet - 3

BRCS01C AC/DC Residual Current Sensor - Type-A 30 mA and/or DC 6 mA Residual Current Detection Characteristics Operating Current

Open the catalog to page 3
BRCS01C_Datasheet - 4

BRCS01C AC/DC Residual Current Sensor - Type-A 30 mA and/or DC 6 mA Additional information • Attention: A Mosfet is built in the 12V DC sensor to switch the connection to signal V- as normal using. The maximum switching current of the 12V DC sensor is 500mA. • Attention: Pin 6 is only for internal use by the sensor. It shall be kept floating (not connected).

Open the catalog to page 4
BRCS01C_Datasheet - 5

BRCS01C AC/DC Residual Current Sensor - Type-A 30 mA and/or DC 6 mA A self-test excluding offset calibration is activated if Pin 3 - Test is connected to a high level for a period of 40ms to 1000ms. t1 is the response time for internally generated test current. Offset calibration time chart Possible Output States Status A change from GND to High impedance is allowed, as long as such a change is compliant with IEC 62955.

Open the catalog to page 5
BRCS01C_Datasheet - 6

BRCS01C AC/DC Residual Current Sensor - Type-A 30 mA and/or DC 6 mA Application Notes of 5V DC Version Typical application diagram BRCS01C 5V version A direct connection of Pin 2/6 to switching devices such as relays or contactors- is NOT allowed. The trip signal of Pin2/6 is suggested to be monitored by the charging controller MCU.

Open the catalog to page 6
BRCS01C_Datasheet - 7

BRCS01C AC/DC Residual Current Sensor - Type-A 30 mA and/or DC 6 mA A self-test excluding offset calibration is activated if Pin 5 - Test is connected to a high level for a period above 40ms. t1 is the response time for internally generated test current. Offset calibration time chart An offset calibration is activated if Pin 4 - CAL is connected to GND for a period of 50ms to 100ms. An offset calibration can be activated at regular intervals (such as start-up) or after the occur of certain critical events (such as short circuit). Attention: During the offset calibration, NO leakage current...

Open the catalog to page 7
BRCS01C_Datasheet - 8

BRCS01C AC/DC Residual Current Sensor - Type-A 30 mA and/or DC 6 mA

Open the catalog to page 8
BRCS01C_Datasheet - 9

BRCS01C AC/DC Residual Current Sensor - Type-A 30 mA and/or DC 6 mA Additional Notes • Do NOT allow strong static electricity near the sensor, because static electricity can cause damage to the ICs inside the sensor. Take static electricity precautions when handling. • Do NOT drop the sensor or apply any other mechanical stress to the sensor, as such stresses may change performance characteristics. • Please place the sensor with an appropriate distance from components that can generate high magnetic fields, such as relays or contactors, to ensure accurate residual current detection. •...

Open the catalog to page 9