BRCM01C_Datasheet
7Pages

{{requestButtons}}

Catalog excerpts

BRCM01C_Datasheet - 1

BRCM01C AC/DC Residual Current Monitor - Type-A 30 mA and/or DC 6 mA BRCM01C AC/DC Residual Current Monitor for Charging Equipment of Electric Vehicles - 12V DC interfaces facilitating compatible integration to EV charging controllers Two fault signal pins for solely DC 6mA and Type-A 30mA +DC 6mA alarming Cost-effective solution of built-in residual current device for AC EV charger Fast response time facilitating a broad selection of switching devices Compact design with 17mm through-hole for charging cable up to 3P+N 32A

Open the catalog to page 1
BRCM01C_Datasheet - 2

BRCM01C AC/DC Residual Current Monitor - Type-A 30 mA and/or DC 6 mA Technical Specification # Technical Specification Rated operating voltage in monitoring circuit Rated current in monitoring circuit Poles in monitoring circuit Frequency in monitoring circuit Rated impulse withstand voltage in monitoring circuit Over-voltage category in monitoring circuit Rated operating voltage in control circuit, Vcc Power consumption AC&DC fault signal Rated DC residual operating current I△dc Rated DC residual non-operating current I△ndc Rated AC residual operating current I△n Rated AC residual...

Open the catalog to page 2
BRCM01C_Datasheet - 3

BRCM01C AC/DC Residual Current Monitor - Type-A 30 mA and/or DC 6 mA Residual Current Detection Characteristics AC&DC fault signal Operating current for smooth DC1) Operating current for DC rectified from 2 phases Operating current for DC rectified from 3 phases Operating current for sinewave AC Operating current for A0 pulsating DC Operating current for A90 pulsating DC Operating current for A135 pulsating DC Response time for 6mA smooth DC residual current Response time for 60mA smooth DC residual current Response time for 200mA smooth DC residual current Response time for 300mA smooth DC...

Open the catalog to page 3
BRCM01C_Datasheet - 4

BRCM01C AC/DC Residual Current Monitor - Type-A 30 mA and/or DC 6 mA Application Notes Typical application diagram EV charging controller Attention: A Mosfet is built in the 12V DC sensor to switch the connection to signal V- as normal using. The maximum switching current of the 12V DC sensor is 500mA. Attention: Pin 6 is only for internal use by the sensor. It shall be kept floating (not connected).

Open the catalog to page 4
BRCM01C_Datasheet - 5

BRCM01C AC/DC Residual Current Monitor - Type-A 30 mA and/or DC 6 mA Self-test time chart A self-test excluding offset calibration is activated if Pin 3 - Test is connected to Vcc for a period of 40ms to 1000ms. t1 is the response time for internally generated test current. Offset calibration time chart An offset calibration is activated if Pin 3 - Test is connected to Vcc for a period of 4.5s± 5%. An offset calibration can be activated at regular intervals (such as startup) or after the occur of certain critical events (such as short circuit). Attention: During the offset calibration, NO...

Open the catalog to page 5
BRCM01C_Datasheet - 6

BRCM01C AC/DC Residual Current Monitor - Type-A 30 mA and/or DC 6 mA Ordering information # Order Number BRCM01C Residual Current Sensor 12V DC Interface, Hanging around main cable (Flexible) Type A 30 mA+DC6mA / DC6mA, 32A, 1P+N / 3P+N HY 2.0 -6 pin

Open the catalog to page 6
BRCM01C_Datasheet - 7

BRCM01C AC/DC Residual Current Monitor - Type-A 30 mA and/or DC 6 mA © Copyright 2023 Bituo Technik. All rights reserved. Specifications and illustrations subject to change without notice.

Open the catalog to page 7