Catalog excerpts
SETEBOS-2S Ethernet/GSM/RS232/485/IO/TH control and measuring unit with automation control functionality • • Possibility of adding extension modules: additional inputs, outputs, size measurements Remote, full software update SETEBOS-2S may be fitted with a whole range of wireless communication interfaces allowing monitoring and control of elements installed in the building and not directly plugged into the device, as well as connectivity with user mobile devices (tablet, Smart-building automation control in communication with an external mobile (phone, tablet) or PC application In its base functional application, SETEBOS-2S serves as control and measuring unit dedicated to object supervision and control, registering environmental parameters such as temperature and humidity. Additionally, the respective inputs allow building violation detection, flooding, etc. Furthermore, the device facilitates remote control of devices installed in the monitored facility via two relay contact outputs. RS232/485/422 interfaces allow communication with external devices via Ethernet/IP networks, or connection of peripherals or extensions for the measuring and monitoring functions. The in-built serial interface allows the connection of additional external modules to further expand the device's functionality. Relay output control, NO/NC ports 1x 10/100/Mbit/s Ethernet – management/ monitoring 1-wire interface to external sensors of temperature, humidity, other measurable values, dew point calculation, or multi-point internal temperature monitoring Digital inputs with "dry contact" optical isolation 3x RS232/RS485/RS422 interfaces with galvanic separation, for the transfer of RS contact for external device management or communication with sensors, including one virtual-com HTTP/HTTPS, SNMP v3, SMTP, TELNET/SSH, SNTP, Syslog management Operating temperatures from -40 to +70°C Durable metal casing IP-30 DIN DC power supply mobile phone, etc.) with the provided control application installed. Depending on the version, it can be powered directly from locally available, DC power sources. Management The inclusion of a HTTP/HTTPS server, a TELNET/SSH server and SNMP/SNMPv3 agent facilitates free configuration of the devices parameters using a WWW browser or constant monitoring of the device's condition from any SNMP compatible management platform. Moreover, the included SMTP support allows operator notification via email if any system-defined event is detected. The content of messages sent by the device via SNMP (TRAP) and syslog protocols is fully customisable. Dedicated applications are provided with an application which, depending on the modules installed, can be used for object control and monitoring purposes as well as smart-building automation control based on the applicable. al
Open the catalog to page 1Fig. 1 Example application illustrating the connection of peripheral systems for the measurement of detector state or environmental conditions in maintenance-free stations. One of the possible usages is control and environment monitoring in server room. Example of such application is presented on the drawing below. Fig. 2 One example of device use is server room monitoring: Door opening detector connected to digital input, informs about violation of the facility's space Alarm sirene, can be switch on using digital output Smoke detector, informs about fire presence Temperature and humidity...
Open the catalog to page 2Ethernet interfaces: Temperature and humidity measurement interface Range of temperature measurement: -40 +125 °C Range of humidity measurement: 0-100% RH Accuracy of humidity measurement: +/-2% RH Maximum number of sensors T = 4 and T/H=2 Connector: screw terminals Interface configuration: Connector: screw terminals GPRS/EDGE, UMTS, CDMA, LTE standards Radio frequencies: 800/900/1800/2100/2100 MHz 2(3)x SMA aerials Operation status and signal quality signalling Automatic login and packet session established in APN after unsuccessful attempts to reboot the device Supply voltage range: 30 ÷...
Open the catalog to page 3GSM/RF module: No symbol** - basic version GSM* - router equipped with a GSM modem RF* - router equipped with a radio module GSM + GSM* - router equipped with GSM modems with redundancy GSM + RF* - router equipped with GSM module and radio module Power Supply: 4 - Power supply 30 - 60VDC 5 - Power supply 9 - 36VDC * - When completing the set, provide the module reference. Available modules in the table below. ** - The device in the basic version doesn‘t have the possibility of expansion in the future. Additional Interfaces I/O: IO - See the module list List of available modules: SETEBOS-2S:...
Open the catalog to page 4Control and measuring unit with built-in GSM module, Ethernet/RS232/485/IO/TH, Interfaces: 1x RJ45 (10M/100M/1G), 3x RS232/RS485/RS422; connectors NO/NC, 1-wire, 2x digital inputs, 4x relay outputs, USB CLI port, Management: HTTP/HTTPS, SSH, SNMPv3, SMTP, TELNET, SNTP, Syslog Operating temperature: -40°C to +70°C, Solid IP-30 DIN mounted metal enclosure, Power supply: 9-36V DC Additional accessories: T/H-2 sensor T/H sensor - cable length 2m (possibility of connecting to two sensors) REL48 External relay with a holder for mounting on a DIN rail to control 230V devices (48V coil) REL230...
Open the catalog to page 5All BITSTREAM S.A. catalogs and technical brochures
-
Quazar 700 Rubidium
9 Pages
-
QUAZAR 700
9 Pages
-
QUAZAR 100
7 Pages
-
MAGNETAR 105
8 Pages
-
RSMUX3
6 Pages
-
RSMUX2
6 Pages
-
SE-39
5 Pages
-
Eris-100
7 Pages
-
BS-MX-110
7 Pages
-
Hyperion 402
10 Pages
-
Hyperion 200
10 Pages
-
Hyperion 105
10 Pages
-
Hyperion 300
10 Pages
-
Hyperion 500
10 Pages