Overview: The Rheotherm Model 210 is a thermal mass flowmeter designed for challenging environments, offering high accuracy, robust construction, and reliability. It is customizable for specific process needs, including material, connections, and temperature and pressure ranges.
Method of Operation: The flowmeter uses two sensors: a Reference and Heated Resistance Temperature Detector (RTD). The upstream RTD measures fluid temperature, while the downstream RTD is heated. The temperature difference (ΔT) is proportional to the mass flow rate, decreasing as flow increases.
Features and Benefits: The Model 210 provides ±1% accuracy, ±0.5% repeatability, and a 1-second response time. It supports a wide range of temperatures and pressures, with advanced temperature compensation and multiple calibration storage. Available in inline or insertion probe configurations.
Specifications: The flowmeter has no moving parts, ensuring reliability and low maintenance. It is suitable for sanitary applications and offers field-adjustable calibration. Supports analog and digital outputs, including Modbus RTU and Hart protocols.
Advanced Features: Calibrated at four different temperatures for accuracy across conditions, with extended calibration options and field adjustments for substitute fluids.
Low Flow Controller: An add-on for measuring and controlling low flow rates of gases and liquids, featuring precision control and user-adjustable setpoints.
Hazardous Location Options: Available in explosion-proof designs for hazardous areas, with integrated electronics and optional NEMA 7 enclosures.
Radiation Hardened Flowmeters: Suitable for high radiation environments, offering low and high radiation hardness levels for nuclear applications.
Rheovec Sensor Heads: Designed for difficult duct flows, improving accuracy by eliminating off-axis velocity errors.
Transducer Selection Guide: Provides guidelines for selecting inline and probe type transducers based on flow rate limits and application requirements.
Model Selection Guide: Details the process for selecting the appropriate Rheotherm model, including enclosure, display, transducer type, and material options.
Specifications:
1. Stream Temperature: Operates between 0°C to 60°C (32°F to 140°F). For higher temperatures, specifications must be provided.
2. Operating Pressure: Options for low or high pressure (≥1,000 psi).
3. End Fittings: Options include plain tube, ¼" O.D. tube stubs, flanged, or specified fittings.

Output Options:
1. Voltage outputs: 0 to 5 Vdc, 0 to 10 Vdc.
2. Current output: 4 to 20 mA - isolated.
3. Pulse outputs: 5 Vdc frequency or open collector.
4. Temperature outputs: 0 to 10 Vdc, 0 to 5 Vdc, 4 to 20 mA.
5. Time delay for flow switch.

Power Options:
1. 12 Vdc, 24 Vdc, 120 Vac (50/60 Hz), 220 Vac (50/60 Hz).

Relay Options:
1. One or two SPDT flow switch relays.

Additional Options:
1. Intrinsically safe cable interface with FM approved I.S. system.
2. Multiple fluid calibrations, extended range, cleaned for high purity service, steam jacket, extra transducer cable, flow controller add-on, potentiometer controlled, external 0-5V input controlled.

Model 210 Typical Dimensions:
Various TU transducer sizes with specific dimensions for shell length, diameter, and cable length.

Enclosure Options:
Model 210 and 210R enclosures with various sizes and mounting options, including NEMA 4 and explosion-proof designs.

Contact Information:
Phone: (614) 895-0301
Email: [email protected]
Website: www.bioneticsflow.com
Address: The Bionetics Corporation: CESG, 770 Brooksedge Plaza Dr., Westerville, OH 43081
See more

Catalog excerpts

Rheotherm Model 210 -1

Rheotherm Model 210 INLINE FLOWMETERS AND PROBES Bionetics Corporation 770 Brooksedge Plaza Dr [email protected] www.bioneticsflow.com

 Open the catalog to page 1
Rheotherm Model 210 -2

The Rheotherm Model 210 is a Thermal Mass flowmeter designed for the most demanding measurement environments and the most challenging applications. From chemical processing to water treatment, and nuclear reactors to the international space station, Rheotherm Flow Instruments have a legacy for accuracy, robust construction, and reliability. The Rheotherm product line is largely customizable to your process needs. The wetted material, process connections, temperature and pressure range, are all customizable for your specific application, Ensuring you get the right sensor for your needs, every...

 Open the catalog to page 2
Rheotherm Model 210 -3

Measure Liquid and Gas Flows Store and Switch Between up to Four Calibrations Advanced Temperature Compensation Remote and Integral Electronics Options Available FM Approved Models for Explosive Environments and Intrinsic Safety Custom Selectable Process Connections Accuracy: Repeatability: Line Size: Response Time: Process Temp: Ambient Temp: Process Pressure Input Power: Signal Outputs: FEATURES BENEFITS No Moving Parts and High Reliability Lifespans of Over 20 Years are Common Low Pressure Drop, Non-Intrusive Designs Compatible with Sanitary Applications & Clean-InPlace Choice of Wetted Materials...

 Open the catalog to page 3
Rheotherm Model 210 -4

Model 210 Features Advanced Temperature Compensation The Rheotherm Model 210 is capable of being calibrated at 4 different process temperatures, ensuring continuous accuracy even when process conditions change over a wide range. Every attempt is made to calibrate flowmeters under the actual process fluid and process pressure and temperature conditions. This makes Rheotherm flowmeters some of the most accurate in the industry. Extended Calibration Options Storage of up to 4 calibrations on different fluids, with 4 temperature ranges available on each. These can be selected for changes of process...

 Open the catalog to page 4
Rheotherm Model 210 -5

The Bionetics Corporation: CESG 770 Brooksedge Plaza Dr. Westerville, OH 43081 Rheotherm Flow Controller Trusted Rheotherm precision with added functionality The Bionetics Rheotherm Model 210 Low Flow Controller is an add-on for the Model 210 flowmeter that can be used to measure and control the continuous flow of most gases and homogeneous liquids with low or high viscosities. Like all Rheotherm instruments, the Rheotherm Model 210 Low Flow Controller is capable of measuring and controlling extremely low flow rates while providing accurate results. Key features include: • Precision low flow...

 Open the catalog to page 5
Rheotherm Model 210 -6

The Bionetics Corporation: CESG 770 Brooksedge Plaza Dr. Westerville, OH 43081 Phone: (614) 895-0301 [email protected] www.bioneticsflow.com Hazardous Location Options C1D1 FM Classified Areas Bionetics offers a line of flow meters and flow switches in a variety of configurations suitable for the most demanding industry needs. Capable of measuring both liquids and gases, Rheotherm instruments are commonly installed in hazardous (classified) areas. The Model 210 flow meter is available in an FMapproved explosion-proof design (*areas only) incorporating integrated electronics for both insertion...

 Open the catalog to page 6
Rheotherm Model 210 -7

The Bionetics Corporation: CESG 770 Brooksedge Plaza Dr. Westerville, OH 43081 Environments with high levels of radiation create special challenges, as a single charged particle can knock thousands of electrons loose, leading to signal spikes and electronics noise, which may result in inaccurate or unintelligible signals. This is a particularly serious problem in the design of spacecraft and nuclear power stations. For nearly 50 years, Rheotherm flow meters have proven to be a robust and accurate solution for industrial and aerospace flow measurement applications. A low maintenance design with...

 Open the catalog to page 7
Rheotherm Model 210 -8

The Bionetics Corporation: CESG 770 Brooksedge Plaza Dr. Westerville, OH 43081 Rheovec Sensor Heads • Measure true gas mass flow in ducts and pipes • Obtain accurate velocity profiles in highly turbulent and swirling flow streams • Reliably measure flow at lower cost than averaging arrays An additional option: If desired, the probes can be ordered with and adjustable insertion depth. During initial use, flow rate readings at multiple insertion depths can be obtained and averaged, allowing the user to determine a final installation depth that provides a reading close to the average flow in the...

 Open the catalog to page 8
Rheotherm Model 210 -9

The Bionetics Corporation: CESG 770 Brooksedge Plaza Dr. Westerville, OH 43081 , ,, , . *Available as Flow Switch only Q = Flow rate (SCFM) A = Cross sectional area of duct or pipe (ft2) 1: Based on water 2: Based on air

 Open the catalog to page 9
Rheotherm Model 210 -10

The Bionetics Corporation: CESG 770 Brooksedge Plaza Dr. Westerville, OH 43081 MODEL SELECTION: Rheotherm model code numbers start with the basic model selected for an application (e.g., 210). The rest of the number is a listing of the enclosure, display, transducer type, features, outputs, and other options selected. You may build a model code number from the chart below or simply complete the Flow Application Data sheet and submit it to the factory or your Bionetics representative. All model selections are subject to factory approval. 3. Transducer type / size 5. Temperature / pressure / fittings...

 Open the catalog to page 10
Rheotherm Model 210 -11

The Bionetics Corporation: CESG 770 Brooksedge Plaza Dr. Westerville, OH 43081 r O.D. (A) OVERALL LENGTH (B) SHELL LENGTH (C) SHELL DIAMETER (D) CABLE (F) Non Rated, FM Explosion Proof, FM Intrinsically Safe, cFM Explosion Proof Non Rated, FM Intrinsically Safe FM/cFM Explosion-Proof or FM Intrinsically Safe Non Rated or FM Intrinsically Safe

 Open the catalog to page 11
Rheotherm Model 210 -12

The Bionetics Corporation: CESG 770 Brooksedge Plaza Dr. Westerville, OH 43081 r FM APPROVED PROBE TRANSDUCERS NPT/I 1" MNPT Variable 7 (178) 3/4" FNPT 10 ft (3 m) Dimensions in inches (millimeters). All dimensions subject to change without notice. Up to 200 ft. of cable available. BLIND PROBE TRANSDUCERS - 210 or 210R NPT/I 1" MNPT Variable 6 (152) 1/2" FNPT 10 ft (3 m) Dimensions in inches (millimeters). All dimensions subject to change without notice. Up to 200 ft. of cable available.