1. Catalogs
  2. The Bionetics Corporation (Intek, Inc. assets)
  3. Model 213 Bidirectional Flow Meters

Model 213 Bidirectional Flow Meters

Model 213 Bidirectional Flow Meters

Product catalog summary
Product Overview
Bionetics' Rheotherm Model 213 Bidirectional Flow Meters utilize a series of Resistance Temperature Detectors (RTDs) to measure both the flow and direction of fluids. The system includes two RTDs for fluid temperature measurement and a third RTD for monitoring the temperature of a low-power heater cooled by the fluid flow. The temperature differential between the heated and unheated RTDs provides the primary flow signal, while flow direction is determined by comparing the temperatures of the unheated RTDs.

Key Features
  • Extended temperature compensation ensures reliable flow measurement across a wide range of process conditions.
  • Supports up to four calibration settings for different fluids or flow ranges.
  • Factory calibration is field adjustable to accommodate process changes, reducing the need for recalibrations.
  • Offers a variety of process connections and component configurations for simplified integration.
  • Proprietary design with unstressed components ensures years of reliable operation and reduced maintenance costs.
  • Manufactured under an ISO-9001:2015 certified Quality Assurance program for maximum reliability.
  • FM approved, explosion-proof, and radiation-hardened units are available for demanding applications.

Operational Details
When fluid flows from left to right, RTD1 measures the entering fluid temperature, and RTD2 measures the downstream temperature, which is higher due to the heater. This setup allows for flow direction determination. Conversely, when fluid flows from right to left, RTD2 measures the entering fluid temperature, and RTD1 measures the downstream temperature, indicating the reverse flow direction.

Design and Reliability
  • Compact inline assembly suitable for liquid and gas flow measurement.
  • No moving parts, ensuring maintenance-free operation.
  • Choice of wetted materials and advanced signal processing electronics.
  • Field adjustable for long-term reliability.

Contact Information
Bionetics Corp.
770 Brooksedge Plaza Dr.
Westerville, OH 43081
Phone: 614-895-0301
Fax: 614-895-0319
Email: [email protected]
Website: www.bioneticsflow.com
See more

Catalog excerpts

Model 213 Bidirectional Flow Meters -1

Product Summary FLOW INSTRUMENTS Using a series of Resistance Temperature Detectors (RTDs), Bionetics’ patented Rheotherm flow meters are able to measure both flow and direction. Two RTDs measure fluid temperature and a third RTD measures the temperature of a constant low-power heater which is cooled by the flowing fluid. The temperature differential between the heated and unheated RTDs provides the primary flow signal and flow direction is determined by comparing the temperature of the unheated RTDs. As the fluid flows from left to right, RTD1 measures the temperature of the fluid entering the sensor, and RTD2 measures the temperature of the fluid downstream of heater, which is at a higher temperature when compared to RTD1 and allows the flow direction to be determined. When the fluid is flowing in the opposite direction, RTD2 measures the fluid temperature as it enters the sensor and RTD1 is located downstream of the heater, the temperature of RTD1 is now higher than the temperature at RTD2 indicating flow from right to left.. • No moving parts • Field adjustable • Choice of wetted materials • Maintenance-free • Advanced signal processing electronics • Long-term reliability • Extended temperature compensation for reliable flow measurement over wide range of process conditions • Up to 4 calibration settings to support different fluids or flow ranges • Factory calibration is field adjustable as process changes to reduce need for recalibrations • Variety of process connections and component configurations available simplifies integration • Proprietary design using unstressed components providing years of reliable operation and reduced maintenance cost. • Designed and manufactured under ISO-9001:2015 certified Quality Assurance program for maximum reliability • FM approved, explosion-proof, and radiation hardened units available to meet the most demanding applications 770 Brooksedge Plaza Dr. Westerville, OH 43081 Phone: 614-895-0301 Fax: 614-895-0319 [email protected] www.bioneticsflow.com

 Open the catalog to page 1

All The Bionetics Corporation (Intek, Inc. assets) catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry
DirectIndustry is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. DirectIndustry is an entity of VirtualExpo Group.