video corpo

Bioclean-C Sterile Chemotheraphy Protective Sleeve Cover
2Pages

{{requestButtons}}

Catalog excerpts

Bioclean-C Sterile Chemotheraphy Protective Sleeve Cover - 1

CHEMOTHERAPY Sterile Protective Sleeve Covers About Designed for protection, the BioClean-C™ Sterile Chemotherapy Protective Sleeve Covers have been specially developed for maximum protection against a range of chemotherapy drugs and to be compatible with ISO Class 4 cleanrooms. Constructed from lightweight, low-linting and hard wearing CleanTough™ material, the sleeve covers feature elasticated arms and 100% polyester elasticated cuffs. The 'one size fits all' cover has been tailored for quick and simple donning. Specifications MATERIAL: CleanTough™ material LIGHTWEIGHT & LOWLINTING TESTED AGAINST ASTM D6978-05 100% POLYESTER ELASTICATED CUFFS ULTRASONICALLY BONDED SEAMS COLOUR: Blue CONSTRUCTION: Ultrasonically bonded seams covered with protective tape CLASSIFICATION: PPE Cat 3 Type PB [6] CHARACTERISTICS: Low particulating COMPATIBILITY: ISO Class 4 STERILIZATION: Gamma irradiation Features Tested against ASTM D6978-05 using a minimum of nine cytotoxic drugs Ultrasonically bonded seams with protective tape Elasticated for secure fit Processed to ensure ISO Class 4 compatibility 100% polyester elasticated cuffs Lightweight, low-linting & hard wearing CleanTough™ material Dr Isolator™ represents BioClean’s™ GMP compatible Chem

Open the catalog to page 1
Bioclean-C Sterile Chemotheraphy Protective Sleeve Cover - 2

Quality Standards Manufactured in a facility holding ISO 9001:2008 and 89/686/EEC Article 11b certifications Conforms to Category 3 - Complex Design Personal Protective Equipment PPE Directive 89/686/EEC Tested against standard EN ISO 13034 protective clothing against liquid chemicals (Type PB [6]) Tested against standard EN 14325 protective clothing against chemicals Tested against permeation standard ASTM D6978-05 for cytotoxic drugs Processed in an NEBB certified ISO Class 4 environment Sterilized in accordance with ISO 11137-1:2006 Method: Gamma irradiation Minimum Dose: 25kGy Sterility...

Open the catalog to page 2

All BioClean catalogs and technical brochures

  1. BDBS-G

    2 Pages

  2. BDBN-G

    2 Pages

  3. BDBN

    2 Pages

  4. BDBL

    2 Pages

  5. BCSC

    3 Pages

  6. BCGS1

    3 Pages

  7. B C D A

    3 Pages

  8. BCAS

    3 Pages

  9. BCAP-SS

    2 Pages

  10. BCAH-SL

    2 Pages

  11. BCAH

    3 Pages

  12. BCAG-SL

    2 Pages

  13. BCAG

    3 Pages

  14. BBS-W

    2 Pages

  15. BBPN

    4 Pages

  16. BBC

    2 Pages

  17. BASL

    3 Pages

  18. BAFS-601

    2 Pages

  19. ALB001

    2 Pages

  20. AL300

    3 Pages

  21. Bioclean Neo

    3 Pages