BCAS
3Pages

{{requestButtons}}

Catalog excerpts

BCAS - 1

(ItioClean V_ ■ product ■ protection BIOCLEAN-CCHEMOTHERAPY Protective Apron with Sleeves About The BioClean-C Chemotherapy Protective Apron with Sleeves provides protection against a range of chemotherapy drugs**. Manufactured from lightweight low-linting CleanTough material, the apron features an adjustable neck fastening, tie tapes at the rear and ultrasonically bonded sleeve seams with protective tape. The polyester/Lycra elasticated cuffs ensure a secure hold at wrist to avoid the sleeve from moving and exposing the skin. Passes the ISO 16604 standard for resistance to penetration by blood-borne pathogens. il Specifications MATERIAL: BioClean-C CleanTough blue material COLOUR: Blue CONSTRUCTION: Ultrasonically bonded sleeve seams with protective tape & 85% polyester/15% Lycra elasticated cuffs. CLASSIFICATION: PPE Cat 3 Type PB [6] CHARACTERISTICS: Low particulating COMPATIBILITY: ISO Class 4 Features • Tested against permeation standard ASTM F739-12 • Ultrasonically bonded seams with protective tape • Tie tapes at rear • Adjustable neck fastening • Lightweight low-linting CleanTough material • Silicone-free LIGHTWEIGHT & LOW-LINTING TESTED AGAINST PERMEATION STANDARD ASTM F739-12 TESTED AGAINST PENETRATION STANDARD ISO 16604 ULTRASONICALLY BONDED & TAPED SEAMS

Open the catalog to page 1
BCAS - 2

Quality Standards Shelf Life & Storage Five (5) years from date of manufacture. Store in a dry, cool place (<40°C) away from direct sunlight and fluorescent light. • Manufactured in a facility holding ISO 9001:2015 and (EU)2016/425 Module D certifications • Conforms to Category 3 - Personal Protective Equipment Regulation (EU) 2016/425 • Tested against standard EN ISO 13034:2005 + A1:2009 protective clothing against liquid chemicals (Type PB [6]) • Tested against standard EN 14325 protective clothing against chemicals • Tested against permeation standard ASTM F739-12 • Processed in an NEBB...

Open the catalog to page 2
BCAS - 3

BioClean-C™ CleanTough Blue Material - ASTM F739-12 Test Method Results Mean Breakthrough Time (MBT), Minutes Breakthrough of the test chemical is deemed to have occurred when the permeation rate has reached 0.1 jug/cmfymin Results achieved under controlled laboratory conditions, by accredited external testing laboratory. Re-Order Chest Size Small Medium Large X-Large Packing One piece per sealed inner PE bag; one inner bag per sealed outer PE bag; 40 outer bags per lined carton (40 pieces). For additional information visit us at Nitritex Ltd Minton Enterprise Park Oaks Drive Newmarket,...

Open the catalog to page 3

All BioClean catalogs and technical brochures

  1. BDBS-G

    2 Pages

  2. BDBN-G

    2 Pages

  3. BDBN

    2 Pages

  4. BDBL

    2 Pages

  5. BCSC

    3 Pages

  6. BCGS1

    3 Pages

  7. B C D A

    3 Pages

  8. BCAP-SS

    2 Pages

  9. BCAH-SL

    2 Pages

  10. BCAH

    3 Pages

  11. BCAG-SL

    2 Pages

  12. BCAG

    3 Pages

  13. BBS-W

    2 Pages

  14. BBPN

    4 Pages

  15. BBC

    2 Pages

  16. BASL

    3 Pages

  17. BAFS-601

    2 Pages

  18. ALB001

    2 Pages

  19. AL300

    3 Pages

  20. Bioclean Neo

    3 Pages