AURA PCR DNA CARRY-OVER BLOCKING CABINETS
3Pages

{{requestButtons}}

Catalog excerpts

AURA PCR DNA CARRY-OVER BLOCKING CABINETS - 1

AURA PCRTM DNA CARRY-OVER BLOCKING CABINETS Cod. PC10100 Technical Specifications • • • • • • • • Passive (non-ventilated) PCR cabinet. Automatic switching from UVneutralising mode to operational mode (fluorescent light) Easy to use 60 min timer with 1 min intervals. Fully transparent work chamber, (robust and safe 6mm tempered glass, blocking >98% of UV light) Microswitches to ensure UV light can stay on only when the front glass is closed 100% UV-safe work chamber 3-sectors hinged front window Internal hinged glass shelf for higher comfort and maximum space availability Polyethylene work surface for the highest chemical resistance BioAir S.p.A. - Tel.: +39 0382 6672.1 www.bioair.it - info@bioair.it Numero REA MI – 2577880 Partita IVA e C. Fiscale: 11078210967 - Cap. Soc. Euro 3.000.000 i.v. Sede legale: Via Pagano, 61 - 20145 – Milano - Italy Sede Produttiva: Via Lombardia 12 – 270

Open the catalog to page 1
AURA PCR DNA CARRY-OVER BLOCKING CABINETS - 2

These state-of-the-art PCR cabinets are specially designed for pre-amplification sample preparation in controlled environment in order to prevent DNA carry-over. Any aerosol generated during the handling of the post amplification samples cannot enter the cupboard; any molecule of DNA herein contained is subsequently neutralised with the help of UV radiations. Operating mode: AURA PCR is a very easy-to-operate cabinet. When the normal working procedures have been completed, the tempered glass front panel is closed, and a timer is activated in order to expose all internal surfaces and tools...

Open the catalog to page 2
AURA PCR DNA CARRY-OVER BLOCKING CABINETS - 3

Absorbed power (W): Sustained impact maximum energy of the glass [EN 61010-1, clause 8.2.2] (J): Window glass UVC radiations retention (%): from 10 to 35 80 for temperatures up to 31 °C, decreasing linearly to 50 at 40 °C Maximum relative humidity (%): Max mains supply voltage fluctuations (%): Transient overvoltage category: Pollution degree: 1.3 TRANSPORT AND STORAGE CONDITIONS Ambient temperature (°C): Relative humidity (%): Atmospheric pressure (mbar): Overall L x D x H (mm): Maximum front aperture L x H (mm) : 1.5 MATERIALS Upper structure: cold rolled steel, epoxy powder coated...

Open the catalog to page 3