WL-19D RF Modem Installation and Operating Instructions Read Instructions Completely Before Installing Equipment Installation and Wiring 1. The WL-19D should be mounted high above ground and in a place that gives clear line of sight to the other wireless unit it will be communicating with. The directional yagi antenna is manufactured by CUSHCRAFT and comes with its own set of instructions . Carefully read all instructions before installing the antenna. The cable from the antenna directly connects to the cable from the WL-19D. These N-type connectors are weather proof, however, added sealant over the mated connectors is recommended. IMPORTANT: The antennas at each end of the wireless link should be mounted such that their element(s) have the same orientation. Normal practice is to mount all antennas with their elements vertical as shown Figure 1. LIGHTNING: A low resistance earth ground on the antenna and mast is critical for lightning protection. Some additional degree of lightning protection may be provided by not mounting the yagi antenna as the highest point on a structure. An optional lightning arrester kit is available from BinMaster and should be used in areas where lightning is of concern. The antenna with lightning arrester is shown in Figure 2. 2. The WL-19D will operate from 115 VAC, 230 VAC or 12 to 24 VDC. A voltage selector on the WL-19D circuit board must be set to match the AC input voltage. A separate set of polarized input terminals are provided for DC operation. The DC power may be either ungrounded or have a negative ground. Refer to the wiring diagram shown in Figure 3. All wiring to the unit should be in accordance with the National Electrical Code and any applicable local codes. In all cases, a good electrical earth ground should be connected to the G terminal of the WL-19. 3. A quality shielded twisted pair communication cable such as Belden 9463 should be used for the RS485 network. Connect the RS485 communication cable to the appropriate WL-19D terminals. NOTE: The RS485 network is a polarized (+/-) system. Take care to maintain consistent wire polarity throughout the entire network when connecting to all other devices . 4. TERM: The jumper on the WL-19D circuit board labeled TERM is typically set to the ON position. This is because the WL-19D is usually at one end of the RS485 network cable. If, however, the WL-19D is in the middle of a long network then the TERM jumper would be set to OFF and the devices at each end of the network would have their terminations set to ON. 5. BIAS: Both BIAS jumpers on the WL-19D circuit board are typically set to ON. However, if a computer interface device or other BinMaster controller is also connected to the same wired RS485 network, then that device may be biasing the network in which case the WL-19D BIAS jumpers would be set to OFF. Operation 1. The WL-19D does not require any operator adjustments or actions for operation. 2. The red POWER indicator light located near the RS485 connector on the WL-19D circuit board should be ON whenever power is applied to the unit. 3. There are four other LED indicator lights on the WL-19D circuit board which indicate the following: DI DO Data In, flashes whenever data on the RS485 network is coming into the WL-19D. Data Out, flashes whenever data is moving out of the WL-19D onto the RS-485 network. Garner Industries, 7201 N. 98th St., Lincoln, Nebraska 68507, Phone 800-278-4241 or 402-434-9102
Open the catalog to page 1
Receive, flashes whenever data is being received by the RF modem. Transmit, flashes whenever data is being transmitted by the RF modem. Figure 2 Garner Industries, 7201 N. 98th St., Lincoln, Nebraska 68507, Phone 800-278-4241 or 402-434-9102
Open the catalog to page 2
BIAS JUMPERS (NORMALLY OlSh
Open the catalog to page 3All BinMaster catalogs and technical brochures
-
FeedView brochure
4 Pages
-
CNCR-400 Brochure
2 Pages
-
BMRX-300 Brochure
4 Pages
-
Full Line Brochure
24 Pages
-
NCR-86 Full Line Brochure
8 Pages
-
SmartSonic Brochure
8 Pages
-
Mini Rotary Brochure
2 Pages
-
3D Angled Mounting Flange
1 Pages
-
DPM-100 Display Brochure
2 Pages
-
DPM-200 Display Brochure
2 Pages
-
FVL-200 Brochure
4 Pages
-
SPL-200 Brochure
4 Pages
-
Tilt Switch Brochure
2 Pages
-
C-100 Display Brochure
2 Pages
-
Capacitance Probe Brochure
12 Pages
-
BMRX-200 Brochure
2 Pages
-
BMRX-100 Basic Rotary
2 Pages
-
GWR-3000 brochure
2 Pages
-
Vibrating Rod - 90
2 Pages
-
Vibrating Fork brochure
2 Pages
-
Airbrator
2 Pages
-
Vibrating Rod 90
2 Pages
-
Rotary Product Line Brochure
8 Pages
-
ProCap HD Brochure
1 Pages
-
Capacitance 101
2 Pages
-
BinMaster DPM-300
8 Pages
-
Flow Detect 2000
2 Pages
-
GWR-2000 Guided Wave Radar
4 Pages
-
Adjustable Rotary
1 Pages
-
MultiBob System Brochure
8 Pages
-
CVR-600 Mini Vibrating Rod
2 Pages
Archived catalogs
-
Full Line Product Catalog
24 Pages
-
CNCR Non-Contact Radar
12 Pages
-
3DLevelScanner
8 Pages
-
Full Line Catalog
24 Pages
-
Airpad
2 Pages
-
Vibrating Fork 95
2 Pages
-
NCR-84
4 Pages
-
NCR-25 & NCR-30 Brochure
4 Pages
-
Diffuser Air Pad Brochure
2 Pages
-
DPM-200 Digital Panel Meter
6 Pages
-
SmartBobII MUCM Brochure
2 Pages
-
NCR-80 Accessories Brochure
3 Pages
-
Mini Vibrating Rod
2 Pages
-
Digital Panel Meter Display
8 Pages
-
BinMaster DPM-200
6 Pages
-
BinMaster Rotary brochure
8 Pages
-
Get the Point
7 Pages
-
MND Modbus Network Display
3 Pages
-
DPM-100
8 Pages
-
Binventory Software Brochure
4 Pages
-
VR-0515-NPC
4 Pages
-
NCR-80 Options Brochure
3 Pages
-
NCR-80 Non-Contact Radar
4 Pages
-
3D Angled Mounting Adaptor
2 Pages
-
3D 0 Degree Mounting Flange
1 Pages
-
Mercury_Free Tilt Switch
2 Pages
-
Mini-Rotary Brochure
2 Pages
-
SmartBob2 MUCM Brochure
2 Pages
-
Dust Detect 1000 Brochure
2 Pages
-
Diaphragm Switch Brochure
2 Pages
-
COMPACTPRO Brochure
2 Pages
-
3D Technical Data Brochure
4 Pages
-
WL 19
3 Pages
-
BinMaster Rotary Brochure
8 Pages
-
3D MultiVision Software
4 Pages
-
BinMaster Air Pad Brochure
2 Pages