CNCR Sensor COMPACT NON-CONTACT RADAR Level Sensors for Liquids The CNCR series of compact non-contact radar level sensors uses 80 GHz narrow beam technology for accurate measurement of simple and aggressive liquids. They are easy to setup using Bluetooth on a phone and then send level measurement data to BinView® software, a local display, or a PLC. The sensors offer a measuring range up to 98 feet and install in existing vessel openings or non-intrusively when measuring levels in plastic vessels.
Open the catalog to page 1How CNCR Radars Work The sensor transmits a continuous 80 GHz radar signal through the face of the antenna. The signal is reflected off the material surface and received as an echo by the antenna. The frequency difference between the sent and received signals is converted to a measurement that represents the distance to the material surface. The distance is calculated based upon the vessel height programmed into the unit when it is set up. Setup can be performed without the vessel being emptied to save time. The measurement output is the distance from the face of the antenna to the material surface....
Open the catalog to page 2Reliable Levels in Liquids BinMaster’s CNCR series of compact radar level sensors are used for non-contact level measurement of many types of simple and aggressive liquids of varying densities. These sensors are appropriate for use in drinking and process water and wastewater applications and many water-soluble chemicals. The continuous level sensors also reliably measure in excessive humidity, steam, vapor, and are unaffected by noise. The 80 GHz technology performs accurately if buildup or condensation occurs on the sensor face. Mounting the CNCR The CNCR can be mounted using a wall mounted...
Open the catalog to page 3Cabled Sensors - 100 Series The CNCR-110, 120, 130, and 190 all install using a polyurethane pigtail connection cable available in 16, 32, or 82-foot lengths. These sensors are rated to IP66/IP68 (3 bar) with housings made from durable PVDF material that has excellent chemical, abrasion, and flame resistance and UV stability. The FKM seal provides heat and chemical resistance for long-lasting durability. CNCR-110 The 110 is the ideal sensor for non-contact liquid level measurement at distances up to 26 feet in applications requiring a high level of environmental protection. It features a two-wire...
Open the catalog to page 4CNCR 100 Series S CNCR-130 CNCR-190 MODE OF OPERATION Measuring Principle Measuring Range Beam Angle Unclassified area, non-EX environment, general purpose FM/CSA/CE Unclassified area, non-EX environment, general purpose FM/CSA/CE; FM/CSA/ATEX/ICEx Class I, II, III; ATEX/ ICEx Zone 1, 1/2 Unclassified area, non-EX environment, general purpose FM/CSA/CE; FM/CSA/ATEX/ICEx Class I, II, III; ATEX/ ICEx Zone 1, 1/2 Unclassified area, non-EX environment, general purpose FM/CSA/CE; FM/CSA/ATEX/ICEx Class I, II, III; ATEX/ ICEx Zone 1, 1/2
Open the catalog to page 5Threaded NPT Models - 200 Series The 210, 220, and 230 all mount using a 1.5” threaded NPT or 1.5” threaded straight NPT connection. The enclosures are rated IP66/IP67, Type 4X to protect them from dust and water damage. They are ideal sensors for non-contact level measurement for basic liquid level applications. They are particularly suitable for use in water treatment, storage tanks with acids, lye, and additives in all industrial areas, or for measuring levels in plastic tanks or IBC containers through the tank walls. CNCR-210 The compact 210 is a continuous liquid level sensor with a measuring...
Open the catalog to page 6CNCR-220 CNCR-230 MODE OF OPERATION Measuring Principle Radar Dead Zone None Enclosure Material PVDF Enclosure Rating IP66/IP67, Type 4X Display None 1.5” Threaded Straight Connection One 1/2” NPT without plug in either opening OPERATING CONDITONS Process Pressure -14.5 to +43.51 psi Approvals Unclassified area, non-EX environment, general purpose FM/CSA/CE Radar 49 ft. (15 M) 80 GHz 8° None < 0.2” (5 mm) 12 to 35 VDC 2-wire 4-20 mA PVDF FKM IP66/IP67, Type 4X None 1.5” Threaded NPT, 1.5” Threaded Straight One 1/2” NPT without plug in either opening -14.5 to +43.51 psi (-1 to +3 bar/-100 to +300...
Open the catalog to page 7CNCR Applications Food for Humans and Animals Food ingredients: Liquid ingredients take many forms such as sugars, extracts, and oils that can be translucent, opaque, or transparent. Beverages: Makers of soft drinks, beer, liquor, energy drinks, or seltzers use water, juices, colorants, and additives in the production process. Animal fat: This ingredient is used at feed mills for feedstuffs for livestock and in pet foods. It is also used in the production of soap, lubricants, and fatty acids. Milk and dairy products: Raw milk storage, processing, and pasteurization tanks. Fat and oil processing:...
Open the catalog to page 8CNCR Applications Industrial Process water: To ensure pressure pumps deliver a continuous supply of process water by monitoring the levels in storage tanks or open basins. Bulk industrial containers: Measuring levels in IBCs, drums, or totes installing a sensor in the lid or opening or measuring through a plastic wall. Industrial fluids: Hydraulic fluid, coolants, solvents, cleaners, lubricants, detergents, defoamers, degreasers, brighteners, cutting oils, metalworking fluids, rust and scale removers, and inhibitors. Industrial manufacturing: Process and day tanks, cooling towers, RO storage,...
Open the catalog to page 9CNCR Applications Chemical Chemical processing: Monitor level in bulk storage tanks, industrial bulk containers (IBCs), or drums. Chemical tanks: Measuring the level of tanks where water is being treated with chemicals or clarifiers to ensure tanks are filled at levels for optimum dosage. Conditioning tanks: To ensure chemicals and precipitants are applied properly in optimal, low concentrations. Glues and adhesives: Measuring animal-based or synthetic adhesives containing PVA, ethanol, acetone, and other substances. Environmental Sewer overflows: Level monitoring to prevent capacity overloads...
Open the catalog to page 10Water & Wastewater Municipal water treatment: Monitoring levels in open channels, lagoons, canals, lift stations, sediment tanks, clarifiers, and chemical feeding tanks. Pumping stations: Level measurement at the inlet shaft is used to control running of the pumps by alerting when they need to be turned on or off. Elevated storage tanks: Level monitoring is important to be sure that water pressure and supply is adequate during peak demand periods. Overflow basins: Sensors can provide overflow protection for sewage treatment plants during flooding or stormwater during heavy rainfall. Flocculant...
Open the catalog to page 1112 Pages
4 Pages
2 Pages
4 Pages
24 Pages
8 Pages
8 Pages
2 Pages
2 Pages
2 Pages
4 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
4 Pages
2 Pages
8 Pages
2 Pages
1 Page
2 Pages
8 Pages
1 Page
8 Pages
2 Pages
8 Pages
2 Pages
2 Pages
24 Pages
3 Pages
3 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
7 Pages
8 Pages
6 Pages
8 Pages
2 Pages
2 Pages
6 Pages
2 Pages
4 Pages
4 Pages
4 Pages
3 Pages
2 Pages
4 Pages
24 Pages
3 Pages
4 Pages
8 Pages
3 Pages
2 Pages
2 Pages
4 Pages
8 Pages
2 Pages