video corpo

BinMaster DPM-300
1 / 8Pages

Catalog excerpts

BinMaster DPM-300 - 1

Modbus Master, Slave, or Snooper FEATURES • Large 1.80" Digits • Dual-Line 6-Digit Display • Readable from up to 100 Feet (30 Meters) Away • Superluminous Sunlight Readable Display • NEMA 4X, IP65 Rated Field Mountable Enclosure • Operating Temperature Range of -40 to 65°C (-40 to 150°F) • Modbus® RTU Master, Slave, or Snooper Mode • Poll and Display up to 16 Process Variables • Addition, Difference, Average, Multiplication, Division, Min, • Max, Weighted Average, Ratio, Concentration, & More • Universal 85-265 VAC, or 12-24 VDC Input Power Models • 2 or 4 Relays + Isolated 4-20 mA Output Options • Onboard USB & RS-485 Serial Communication Options • Program the Meter from a PC with onboard USB and ScanView • UL & C-UL Approved SiUMASTER www.binmast

Open the catalog to page 1
BinMaster DPM-300 - 2

Large Display Modbus Scanner NEMA 4X, IP65 Rated Enclosure UV Resistant Sunlight Readable Display User Configurable Display (Showing Custom Tag) Alarm Status Indicators Connections and Function Keys Easily Accessible Behind Front Panel Door Take Advantage of Your Modbus enabled Transmitters Superluminous Sunlight Readable Display As a Master, the DPM-300 reads up to 16 slave devices, scales the data from each, and displays each on an alternating display. Custom Tag and Units for Each PV The DPM-300’s standard SunBright display features extraordinarily bright LEDs. It is perfect for...

Open the catalog to page 2
BinMaster DPM-300 - 3

Large Display Modbus Scanner Typical Modbus Application Example PD2-6080 Master Tanks with multivariable transmitters PC Laptop running Scan View Software Customizable Displays The DPM-300 has two red LED displays, one Upper display and one Lower display both at 1.8" high. Each display is a full 6 digits (-99999 to 999999). The display assignment is programmable, allowing for various one line or two line PV configurations. Modbus Application Capabilities The DPM-300 scanner can communicate with any Modbus device using the ever-popular Modbus communications protocol. Take advantage of the...

Open the catalog to page 3
BinMaster DPM-300 - 4

Large Display Modbus ScannerThree Tier Password Protection DiGiTAL COMMUNiCATiONS The DPM-300 offers 3 levels of password protection: • Level 1 protection allows the operator use of only the 3 preconfigured function keys without a password. • Level 2 protection allows the operator use of only the function keys and the ability to change set points without a password. • Level 3 protection restricts the operator from using the function keys and all meter configuration menus without a password. Advanced Linearization Capability The DPM-300 includes a 32-point linearizer for PV1 & PV2 (all...

Open the catalog to page 4
BinMaster DPM-300 - 5

Large Display Modbus Scanner OUTPUTS Interlock Relay(s) Each output of the DPM-300 may be assigned to any single analog input, Modbus PV, or math PV. The output will reflect the state of that assigned variable at all times during scanning. Relay Outputs The DPM-300 has up to four 3 A Form C relays (SPDT) with multiple power loss fail-safe options. Relays can be configured for proper protective action upon input loop break. Relay ON and OFF delay times are user adjustable. Up to four front panel indicators show alarm and/ or relay state. All relays can be configured for 0-100%...

Open the catalog to page 5
BinMaster DPM-300 - 6

Large Display Modbus Scanner SPECiFiCATiONS Except where noted all specifications apply to operation at +25°C. General input/Output: Modbus RTU over RS-485, Two analog inputs (4-20 mA, ±10 V) Display: Two lines with 1.8” (46 mm) high digits, red LEDs; 6 digits per line (-99999 to 999999), with lead zero blanking Display intensity: Eight user selectable intensity levels Display Update Rate: 5/second (200 ms) seconds. Slave: Dependent on master device (e.g. PLC) Overrange: Display flashes 999999 Underrange: Display flashes -99999 Programming Methods: Four programming buttons, digital inputs,...

Open the catalog to page 6
BinMaster DPM-300 - 7

Large Display Modbus Scanner Isolated 4-20 mA Transmitter Output Output Source: Process Variable 1-16, math channels C1-C4, set points 1-4, or manual control mode Scaling Range: 1.000 to 23.000 mA for any display range Calibration: Factory calibrated: 4.000 to 20.000 = 4-20 mA output Analog output Programming: 23.000 mA maximum for all parameters: Overrange, underrange, max, min, and break Communications Break: Programmable mA output when a slave device does not reply within the response timeout accuracy: ± 0.1% of span ± 0.004 mA Temperature Drift: 0.4 |jA/°C max from 0 to 65°C ambient,...

Open the catalog to page 7
BinMaster DPM-300 - 8

P* P- F4 JCOM Vf mAf|COM V* mA+| Connector labeling for a fully loaded DPM-300 ORDERING INFORMATION Mounting Hole \ rw Mounting Hole Disclaimer The information contained in this document is subject to change without notice. BinMaster makes no representations or warranties with respect to the contents hereof, and specifically disclaims any implied warranties of merchantability or fitness for a particular purpose. ©2018 BinMaster. All rights reserved. Division of Garner industries 7201 North 98th Street | Lincoln, NE 68507-9741 | (402) 434-9102 | Fax: (402) 434-9133

Open the catalog to page 8

All BinMaster catalogs and technical brochures

  1. Airbrator

    2 Pages

Archived catalogs

  1. Airpad

    2 Pages

  2. NCR-84

    4 Pages

  3. DPM-100

    8 Pages

  4. VR-0515-NPC

    4 Pages

  5. WT 19

    3 Pages

  6. WL 19

    3 Pages