Catalog excerpts
Standard-Incubators Avantgarde.Line BD | BF series Classic.Line B| BD| BF series Solid.Line BD-S series
Open the catalog to page 1PRODUCT SELECTION INCUBATORS Temperature range 5 °C above ambient temperature to [°C] Temperature range 7-8 °C above ambient temperature to [°C] Temperature range 10 °C above ambient temperature to [°C] Natural convection Forced convection Ramp function Temperature dependent delayed OFF Real-time clock Class 3.1 independent temperature safety devic
Open the catalog to page 2Incubators Avantgarde.Line The completely redesigned Avantgarde.Line incubators with natural convection or forced convection are now the perfect solution when it comes to meeting growth and incubation requirements. With their exceptional efficiency and perfect temperature accuracy thanks to the very latest APT.line™ technology, this new generation of incubators has real appeal.
Open the catalog to page 3Product selection | Incubators Avantgarde.Line PRODUCT SELECTION INCUBATORS AVANTGARDE.LINE Features Temperature range 5 °C above ambient temperature to [°C] Temperature range 7-8 °C above ambient temperature to [°C] Temperature range 10 °C above ambient temperature to [°C] Natural convection Forced convection General data Controller and timer functions Controller display Ramp function Temperature dependent delayed OFF Class 3.1 independent temperature safety device
Open the catalog to page 4Incubators Avantgarde.Line | Advantages at a glance EASY DATA LOGGING EASY, INTUITIVE HANDLING A USB connector comes standard. The state-of-the-art controller is equipped with an easy-to-read alphanumeric display with various functions facilitating dialog with the unit and the readability of data. BEST ENERGY EFFICIENCY ON THE MARKET AND LOW INSTALLATION REQUIREMENTS COMPLETELY HOMOGENEOUS TEMPERATURE DISTRIBUTION thanks to low heat dissipation and an optimized heating system. This feature provides excellent spatial and temporal temperature accuracy with the all-new generation of APT.line™...
Open the catalog to page 5Series BD Avantgarde.Line | Incubators Avantgarde.Line Series BD Avantgarde.Line | with natural convection The BD Avantgarde.Line series is specially designed for gentle incubation of organisms, as well as conditioning of heatsensitive media. The new design of the units and the homogeneous temperature distribution ensure the very best results. MAIN FEATURES • • • • • • Temperature range: ambient temperature plus 5 °C to 100 °C High temperature accuracy thanks to APT.line™ technology Natural convection Controller with LCD display Electromechanical control of the exhaust air flap Inner door...
Open the catalog to page 6Incubators Avantgarde.Line | Series BD Avantgarde.Line TECHNICAL DATA Description Net weight of the unit (empty) [kg] Temperature range 5 °C above ambient temperature to [°C] Recovery time after 30 seconds door open at 37 °C [min] Nominal power (version 120 V) [kW] Nominal power (version 230 V) [kW] Nominal power (version 240 V) [kW] Outer dimensions Internal Dimensions Performance Data Temperature Electrical data Fixtures Number of shelves (std./max.) ORDERING INFORMATION [Art. No.] Further details: Go to www.binder-world.com > Search > Enter Article Number Option model ▶ You will find a...
Open the catalog to page 7Series BD Avantgarde.Line | Incubators Avantgarde.Line DIMENSIONS incl. fittings and connections [mm] BD 56
Open the catalog to page 8Incubators Avantgarde.Line | Series BF Avantgarde.Line Series BF Avantgarde.Line | with forced convection The BINDER incubator of the BF Avantgarde.Line series with forced convection is suitable for all gentle incubation applications, particularly under a full load and large batch throughputs. This incubator is extremely homogeneous and has quick recovery times. MAIN FEATURES • Temperature range (model 56 | 260): ambient temperature plus 7 °C to 100 °C • Temperature range (model 115): ambient temperature plus 8 °C to 100 °C • High temperature accuracy thanks to APT.line™ technology • Forced...
Open the catalog to page 9Series BF Avantgarde.Line | Incubators Avantgarde.Line TECHNICAL DATA Description Net weight of the unit (empty) [kg] Temperature range 7-8 °C above ambient temperature to [°C] Temperature range 10 °C above ambient temperature to [°C] Recovery time after 30 seconds door open at 37 °C [min] Nominal power (version 120 V) [kW] Nominal power (version 230 V) [kW] Nominal power (version 240 V) [kW] Outer dimensions Internal Dimensions Performance Data Temperature Electrical data Fixtures Number of shelves (std./max.) ORDERING INFORMATION [Art. No.] Further details: Go to www.binder-world.com >...
Open the catalog to page 10Incubators Avantgarde.Line | Series BF Avantgarde.Line DIMENSIONS incl. fittings and connections [mm] BF 56
Open the catalog to page 11Excerpt from options and accessories | Incubators Avantgarde.Line EXCERPT FROM OPTIONS AND ACCESSORIES For introducing external measuring instruments. Large selection of different diameters and posi- Access port with silicone plug tions (left, right, or top) Series BD, BF Waterproof, switched flush-mounting box (CA3GD) for nominal voltage in unit interior, with cover Interior socket and corresponding plug (nominal voltage; max. 500 W; max. 90 °C; protection class IP67) Series BD, BF Lockable door handle prevents unauthorized access. Door lock Perforated shelves or shelf racks, chrome-plated...
Open the catalog to page 12Incubators Classic.Line An incubator from BINDER is the perfect solution for stable incubation processes. With their excellent technical profiles, a BINDER incubator produces reliable incubation of microbiological cultures and guarantee reproducible results in every routine test in the laboratory – even under high batch throughputs in long-term operation. A BD Series incubator functions with natural convection; in a BF Series incubator, convection ensures rapid temperature equalization after the door is opened and quick recovery times.
Open the catalog to page 15Product selection | Incubators Classic.Line PRODUCT SELECTION INCUBATORS CLASSIC.LINE Features Temperature range 5 °C above ambient temperature to [°C] Natural convection Forced convection Ramp function Temperature dependent delayed OFF Class 3.1 independent temperature safety device Temperature alarm, visual General data Temperature
Open the catalog to page 16All BINDER catalogs and technical brochures
-
Drying and heating chambers
50 Pages
-
Growth chambers
8 Pages
-
Cooling incubators
22 Pages
-
CO₂ incubators
23 Pages
-
Walk-in chambers
8 Pages
-
Dynamic climate chambers
34 Pages
-
Constant climate chambers
43 Pages
-
Drying and heating chambers
72 Pages
-
BINDER Product overview
40 Pages
-
BINDER INDIVIDUAL
8 Pages
-
Battery test chambers
22 Pages
-
Vacuum drying chambers
16 Pages
-
Safety drying chambers
12 Pages
-
Ultra low temperature freezers
12 Pages