Drying and heating chambers
72Pages

{{requestButtons}}

Catalog excerpts

Drying and heating chambers - 1

^BINDER Best conditions for your success Drying and heating chambers Avantgarde.Line ED | FD | FP | FED series Classic.Line E | ED | FD | FED | M series

Open the catalog to page 1
Drying and heating chambers - 3

Drying and heating chambers Avantgarde.Line Drying and heating chambers Avantgarde.Line Series ED Avantgarde.Line Page 6 Series FD Avantgarde.Line Page 12 Series FED Avantgarde.Line Page 19 Series FP Avantgarde.Line Page 26 BINDER drying chambers with natural convection or forced convection are renowned for their high quality and reliability. Thanks to their extensive redevelopment, these all-rounders are now even more firmly focused on addressing the requirements involved in drying or heating samples. What's more, in addition to the best energy efficiency on the market and convenient...

Open the catalog to page 3
Drying and heating chambers - 4

Product selection | Drying and heating chambers Avantgarde.Line

Open the catalog to page 4
Drying and heating chambers - 5

Drying and heating chambers Avantgarde.Line | Advantages at a glance EASY DATA LOGGING The USB connector, standard on the ED, FD and FED, provides easy data logging. Ethernet connectivity is standard on FED and an option for ED and FD. EASY, INTUITIVE HANDLING Our state-of-the-art controller with LCD display, excellent readability, alphanumeric display, and various functions provide a user friendly interface. Choice of languages as standard: English, German, and French. BEST ENERGY EFFICIENCY ON THE MARKET AND LOW INSTALLATION REQUIREMENTS thanks to low heat dissipation and an optimized...

Open the catalog to page 5
Drying and heating chambers - 6

Series ED Avantgarde.Line | Drying and heating chambers Avantgarde.Line Series ED Avantgarde.Line | with natural convection The strengths of a BINDER ED series drying chamber include routine drying and sterilization tasks up to 300 °C. Thanks to the natural convection, all thermal processes which use this drying chamber are highly efficient. The ED series ensures fast, uniform drying. MAIN FEATURES • Best energy efficiency on the market • Excellent temporal and spatial temperature accuracy • USB connection for recording data • Temperature range up to +300 °C • Temperature range: +5 °C above...

Open the catalog to page 6
Drying and heating chambers - 7

Drying and heating chambers Avantgarde.Line | Series ED Avantgarde.Line OPTIONAL EQUIPMENT Access port with silicone plug For introducing external measuring instruments. Large selection of different diameters Viewing window and interior lighting Viewing window in the door with a triple-glazed insulating glass and interior lighting for Shelf racks Perforated shelves or shelf racks, chrome-plated or made from stainless steel. and positions (left, right, or top) easy visibility of the samples. Particle filter on fresh air supply for unit; filter classification H14 (acc. to. EN 1822-1:2009, >...

Open the catalog to page 7
Drying and heating chambers - 8

TECHNICAL DATA Measures Interior volume [L] 57 Net weight of the unit (empty) [kg] 42 Wall clearance back [mm] 160 Wall clearance sidewise [mm] 100 Internal Dimensions Width [mm] 360 Housing dimensions not incl. fittings and connections Width net [mm] 560 Performance Data Temperature Temperature range +5 °C above ambient temperature to [°C] 300 Recovery time after 30 seconds door open at 150 °C [min] 19 Tabellen Air change (approx.) at 100 °C [x/h] 8 Electrical data Nominal power (version 120 V) [kW] 1.15 Nominal power (version 230 V) [kW] 1.05 Nominal power (version 240 V) [kW] - Nominal...

Open the catalog to page 8
Drying and heating chambers - 9

Drying and heating chambers Avantgarde.Line | Series ED Avantgarde.Line DIMENSIONS incl. fittings and connections [mm] ED 56 ORDERING INFORMATION OPTIONS Designation Access port with silicone plug Alarm function for overheating for temperature values (output not adjustable) Calibration certificate, expanded Switchable acoustic alarm, with adjustable limit value on the independent temperature safety de

Open the catalog to page 9
Drying and heating chambers - 10

for temperature, measurement in center of chamber at specified tempe- # rature Calibration certificate, temperature temperature measurement incl. certificate and 27 measuring points at specified temperature temperature measurement incl. certificate, 15- 18 measuring points at specified temperature temperature measurement incl. certificate, 9 measuring points at speci- m fied temperature Class 3.1 independent temperature safety with visual alarm (DIN 12880) device Clock battery-backed Door gasket made of FKM, silicone-free Door lock lockable door handle Ethernet interface for Multi...

Open the catalog to page 10
Drying and heating chambers - 12

Series FD Avantgarde.Line | Drying and heating chambers Avantgarde.Line BENEFITS • Best energy efficiency on the market • Excellent temporal and spatial temperature accuracy • USB connection for recording data • Temperature range up to +300 °C MAIN FEATURES • Temperature range: +10 °C above ambient temperature to +300 °C • High temperature accuracy thanks to APT.line™ technology • Forced convection • Controller with LCD display • Electromechanical control of the exhaust air flap • 2 chrome-plated racks • Units up to 115 L are stackable • Class 2 independent temperature safety device (DIN...

Open the catalog to page 12
Drying and heating chambers - 13

Drying and heating chambers Avantgarde.Line | Series FD Avantgarde.Line OPTIONAL EQUIPMENT Access port with silicone plug For introducing external measuring instruments. Large selection of different diameters Viewing window and interior lighting Viewing window in the door with a triple-glazed insulating glass and interior lighting for Shelf racks Perforated shelves or shelf racks, chrome-plated or made from stainless steel. and positions (left, right, or top) easy visibility of the samples. Particle filter on fresh air supply for unit; filter classification H14 (acc. to. EN 1822-1:2009, >...

Open the catalog to page 13
Drying and heating chambers - 14

TECHNICAL DATA Measures Interior volume [L] 60 Net weight of the unit (empty) [kg] 41 Wall clearance back [mm] 160 Wall clearance sidewise [mm] 100 Internal Dimensions Width [mm] 400 Housing dimensions not incl. fittings and connections Width net [mm] 560 Performance Data Temperature Temperature range +10 °C above ambient temperature to [°C] Temperature range +12 °C above ambient temperature to [°C] Recovery time after 30 seconds door open at 150 °C [min] 4 Tabellen Air change (approx.) at 100 °C [x/h] 80 Electrical data Nominal power (version 120 V) [kW] 1.2 Nominal power (version 230 V)...

Open the catalog to page 14

All BINDER catalogs and technical brochures