HAP-P Lubricator

HAP-P Lubricator

HAP-P Lubricator

Product catalog summary
General Description
The HAP-P Lubricator is a manual, one-shot lubricator featuring a spring return piston pump. It operates by pushing a lever to raise a piston, compressing a spring, and discharging oil into the system. The discharge volume and pressure are independent of oil viscosity.
Operation
The lubricator includes a spring return piston pump within a plastic reservoir. Pulling the lever handle fills the cylinder with a predetermined oil volume. Releasing the handle allows spring pressure to discharge the oil into the system, returning the handle to its original position. Operation intervals should follow machine manufacturer recommendations.
Technical Data
  • Reservoir Capacity: 475cc (1 pint)
  • Lubricator Inlet Filter: 40 micron particle separation
  • Discharge Pressure: 60 psi average
  • Factory Discharge Setting: 15cc
  • Piston Diameter: 1/18”
  • Piston Stroke Setting: 1/2 to 1-1/8”
  • Discharge Volume Per Stroke: 5 to 15cc
  • Viscosity Range: 100 to 10,000 SSU at operating temperature
  • Outlet: 1/8”NPTF
Notes Regarding Use
  1. Inspect and clean/replace the lubricator inlet filter periodically.
  2. Discharge pressure decreases with reduced discharge volume and increased meter units.
System & Limitations
Use meter units type F. The total system flow limitation is detailed in a table, indicating the maximum number of meter units and corresponding cc per shot.
Startup Instructions
Fill the reservoir and operate the lubricator until oil flows freely at all bearings.
Maintenance
Inspect the pump inlet filter every six months and replace if necessary. Follow specific steps for filter removal and reinstallation.
Ordering Information
Specify by name and part number when ordering, e.g., Lubricator HAP-P, Part #D3221C.
Service Parts
  • Reservoir: Part #C2966C
  • Filler Cap: Part #B9230C
  • Gasket: Part #B9058
  • Filter Group: Part #S130
Additional Notes
Use only clean oil of the recommended type and viscosity. Replace the filter group annually. Before removing the cylinder cap, ensure the piston is held above the lowest position.
See more

Catalog excerpts

HAP-P Lubricator-1

BIJUR REUNION INTERNATIONAL General Lubricator includes a spring return piston pump and is operated by pushing a lever which raises a piston and compresses a spring, discharging oil into the system. Discharge volume and pressure are independent of oil viscosity. Operation Lubricator includes a spring return piston pump in a plastic reservoir. Pulling up slowly on the lever handle to the stop fills the cylinder with a predetermined volume of oil. Upon release, spring pressure discharges the oil into the system and returns the handle to the original position. Lubricator must be operated at intervals recommended by machine manufacturer. Technical Data Reservoir Capacity 475cc (1 pint) Lubricator Inlet Filter 40 micron particle separation Discharge Pressure 60 psi average Factory Discharge Setting 15cc Piston Stroke Setting 1/2 to 1-1/8" Discharge Volume Per Stroke 5 to 15cc Viscosity range 100 to 10,000 SSU at operating temperature Notes Regarding Use 1. Lubricator inlet filter should be inspected periodically and cleaned/replaced as required. To install replacement, disconnect discharge tubing and remove cylinder cap. 2. Discharge pressure will decrease as discharge volume decreases and the number of meter units in the system increases. System & Limitations Use meter units type F. Total system flow (0) limitation is given in the table below. BIJUR DELIMON INTERNATIONAL (919) 465 4448 LOCAL (800) 631 0168 TOLL-FREE (919) 465 0516 FAX WWW.BIJURDELIMON.COM 2100 Gateway Centre Blvd., Suite 109 Morrisville, NC 27560

 Open the catalog to page 1
HAP-P Lubricator-2

Startup Instructions Use clean oil only of the type and viscosity Fill reservoir; operate lubricator until oil flows freely at all bearings. recommended by machine manufacturer. Iattehtioni Maintenance Filter Replacement A filter at pump inlet protects the lubricating system and should be inspected every six months. If not clean, replace. To remove filter, pry out snap ring with screwdriver and remove filter disc and screens. To re-install, insert in the following order: filter disc support (coarse screen), filter disc screen (fine screen), filter disc, filter clamp ring and filter snap ring....

 Open the catalog to page 2
HAP-P Lubricator-3

Dimensional Schematic Measurements shown in inches. BIJUR DELIMON INTERNATIONAL (919) 465 4448 LOCAL (800) 631 0168 TOLL-FREE (919) 465 0516 FAX WWW.BIJURDELIMON.COM 2100 Gateway Centre Blvd., Suite 109 Morrisville, NC 27560

 Open the catalog to page 3
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.