FD Series Divider Valve
3Pages

{{requestButtons}}

Catalog excerpts

FD Series Divider Valve - 1

FD Series Divider Valve Progressive Systems General FD Series Divider Valves are designed for use with series progressive oil and grease lubrication systems. They are of two piece, steel construction with viton O-ring seals. FD valves will serve 2, 3, 4 or 6 points of lubrication. The 2, 3 and 4 point divider valves require .08 cu in to complete one full cycle. An FD-6 divider valve requires .06 cu in to complete one full cycle. The valves divide the discharge according to the table below. Name Total Discharge per Cycle Positive displacement of lubricant due to precise toleranced clearances. Economical and compact design. Simple to install on new or existing machines. Bolt together construction with viton O-ring seals between sections and piston plug. Operation The FD divider valve is a self-contained, multiple outlet, series progressive valve. The term progressive means that each piston must complete its stroke, discharging a measured amount of lubricant before the following piston operates. As long as lubricant is supplied under pressure to the inlet section, each piston will continue to operate in a progressive manner. When lubricant flow is interrupted to the inlet, piston movement stops. When flow resumes, piston movement commences at the same point in the discharge cycle. Feed lines deliver lubricant from the valve block to individual lube points. Should a discharge line become blocked, it will stop all the valves operating. Indicators are available to alert a blockage. Technical Data Material Maximum Pressure Inlet and Outlet Ports BIJUR DELIMON INTERNATIONAL Assembly Bolts Piston Enclosure Plugs Indicator Plug Torque Ratings * Lubricant is required to cycle divider valve once. 2100 Gateway Centre Blvd., Suite 109 Morrisville, NC 27560

Open the catalog to page 1
FD Series Divider Valve - 2

BIJUR DELIMON FDP (cycle indicator pin - right side) When ordering, specify by name, description and part number, e.g. FD Standard Model, 4 Outlet, Cycle Switch Cycle Switch Bracket Dimensional Schematics Discharge Flow Note: A tee is required for each outlet if a pressure indicator is used with the lubricant to four points. Each point receives Each point receives BIJUR DELIMON INTERNATIONAL 2100 Gateway Centre Blvd., Suite 109

Open the catalog to page 2
FD Series Divider Valve - 3

BUUR DELIMON Dimensional Schematics Measurements shown in inches (mm). Note: Divider systems should be limited to first and second stages only. Third staging is not recommended. BUUR DELIMON INTERNATIONAL 2100 Gateway Centre Blvd., Suite 109

Open the catalog to page 3

All BIJUR DELIMON INTERNATIONAL catalogs and technical brochures

  1. Mobile_BR

    16 Pages

  2. machine tools

    12 Pages

  3. 704

    4 Pages

  4. VXLO Injecto

    3 Pages

  5. DDU Doseur

    3 Pages

  6. Doseur ZDM

    8 Pages

  7. FZ-B Pump

    8 Pages

  8. DS Series

    3 Pages

  9. L-1 Injector

    6 Pages

  10. DYNAMIS Pump

    10 Pages

  11. SUREMATIC Pump

    10 Pages

  12. Airmatic Pump

    21 Pages