Catalog excerpts
Product description Pump AIRMATIC DESCRIPTION A pneumatic pump is designed, depending on the version, to feed oil to resistance (SLR) or volumetric lubrication system (PDI). OPERATION The airmatic is a single action pump piloted by a 3/2 way solenoïd. The oil discharged is released by introducing compressed air into the pump. Oil is sucked into the reservoir as the compressed air in the circuit decompresses with the help of a return spring. For use with volumetric injectors, the pump is equipped with a decompression block wich allows the remainings of the injectors whilst the air circuit is decompressing. Note : Use dry, filtered, lubricated air Principal scheme CHARACTERISTICS Discharge : Air inlet pressure : Air pressure range : Oil pressure : Reservoir capacities : Suction filter : Electric low level switch : Power rating : Cycle frequency : Working temperature : Lubricant to be used : Other lubricant : 1 / 21 2 to 10 ccm / Stroke. 9 Bars max. 4 : 1. 36 Bars max. 1 or 4 liters (plastic). 12 liters (steel). 120 microns. 240 V max. 0.5 A max. Up to 30 cycles per mn. From 5 to 50° max. C Mineral oil viscosity from 30 to 1800 Cst at the working temperature. Contact Bijur Delimon. P_2009_7_Airmatic pump _GB
Open the catalog to page 1HOW TO ORDER Precise designation and reference using the code below : AIR Pump code A Reservoir capacity 1 1 litre 4 4 litres 12 12 litres Distribution system A 2 Resistance B Volumetric D Injection Option B Low level switch (standard) C Low level switch and snap on refill connector automotive version Example : Airmatic pump with 4 litres reservoir and low level switch for volumetric system, Reference : AIR4BBA. 2 / 21 P_2009_7_Airmatic pump _GB
Open the catalog to page 2BUUR DELIMON PUMP AIRMATIC WITH ONE LITRE RESERVOIR Item Description Quantity 7 Discharge adjustment screw 1 8 Electrical low level switch 1
Open the catalog to page 3SERVICE INSTRUCTIONS FOR AIRMATIC PUMP 1L RESERVOIR Start up : Fill the reservoir and connect the air supply. Prime the pump to assure that the system pressurised. Then, follow instructions on the technical date sheet supplied with the unit. Oil : Use only clean mineral oil of a quality and viscosity as recommended by the manufacturer of the machine. Theo il characteristics must allow filtering down to 25 microns without it separating. Service : Control periodically the lubrication lines to make sure none are broken or crushed and that they are in good condition. Ensure all fittings are...
Open the catalog to page 4BUUR DELIMON MAINTENANCE KIT 1L AIRMATIC PUMP RESERVOIR AND PUMP MAINTENANCE KIT FOR RESISTANCE PUMP Reference Description Quantity Check valve Viton seal RESERVOIR AND PUMP MAINTENANCE KIT FOR VOLUMETRICAL PUMP Check valve Viton seal RESERVOIR AND PUMP MAINTENANCE KIT FOR INJECTION PUMP Reference Description Quantity Check valve Straight connector Viton seal
Open the catalog to page 5BIJUR DELIMON PUMP AIRMATIC WITH 4 LITRES RESERVOIR 7 Discharge adjustment screw 8 Electrical low level switch
Open the catalog to page 6SERVICE INSTRUCTIONS FOR AIRMATIC PUMP 4L RESERVOIR Start up : Fill the reservoir and connect the air supply. Prime the pump to assure that the system pressurised. Then, follow instructions on the technical date sheet supplied with the unit. Oil : Use only clean mineral oil of a quality and viscosity as recommended by the manufacturer of the machine. Theo il characteristics must allow filtering down to 25 microns without it separating. Service : Control periodicaly the lubrication lines to make sure none are broken or crushed and that they are in good condition. Ensure all fittings are...
Open the catalog to page 7MAINTENANCE KIT 4L AIRMATIC PUMP RESERVOIR MAINTENANCE KIT Reference A0284 Description Reservoir gasket Filter element Reservoir screw Guide bar Lockwasher Filling filter Plastic reservoir O ring for filling filter Quantity 1 1 1 2 2 4 1 1 RESERVOIR AND PUMP MAINTENANCE KIT FOR RESISTANCE PUMP Reference Description Quantity A0294 Reservoir maintenance kit Check valve Adaptor Viton seal O ring seal Cup seal Gasket 1 1 1 1 1 1 1 RESERVOIR AND PUMP MAINTENANCE KIT FOR VOLUMETRICAL PUMP Description Quantity Reservoir maintenance kit Control unit CTN5 Check valve Viton seal O ring seal Cup seal...
Open the catalog to page 8BIJUR DELIMON PUMP AIRMATIC WITH 12 LITRES RESERVOIR 7 Discharge adjustment screw
Open the catalog to page 9SERVICE INSTRUCTIONS FOR AIRMATIC PUMP 12L RESERVOIR Start up : Fill the reservoir and connect the air supply. Prime the pump to assure that the system pressurised. Then, follow instructions on the technical date sheet supplied with the unit. Oil : Use only clean mineral oil of a quality and viscosity as recommended by the manufacturer of the machine. Theo il characteristics must allow filtering down to 25 microns without it separating. Service : Control periodicaly the lubrication lines to make sure none are broken or crushed and that they are in good condition. Ensure all fittings are...
Open the catalog to page 10MAINTENANCE FOR RESERVOIR KIT 12L RESERVOIR MAINTENANCE KIT Reference A0285 Description Reservoir gasket Filter element Reservoir screw Lockwasher Filling filter Seal for oil sump plug Sight glass Quantity 1 1 8 8 1 1 1 RESERVOIR AND PUMP MAINTENANCE KIT FOR RESISTANCE PUMP Reference Description Quantity A0297 Reservoir maintenance kit Check valve Adaptor Viton seal O ring seal Cup seal Gasket 1 1 1 1 1 1 1 RESERVOIR AND PUMP MAINTENANCE KIT FOR VOLUMETRICAL PUMP Description Quantity Reservoir maintenance kit Control unit CTN5 Check valve Viton seal O ring seal Cup seal Gasket 1 1 1 1 1 1 1...
Open the catalog to page 11Item Description Quantity 7 Discharge adjustment screw 1 8 Electrical low level switch 1
Open the catalog to page 12SERVICE INSTRUCTIONS FOR PUMP WITH 1L RESERVOIR SPECIAL AUTOMOTIVE VERSION Start up : Fill the reservoir and connect the air supply. Prime the pump to assure that the system pressurised. Then, follow instructions on the technical date sheet supplied with the unit. Oil : Use only clean mineral oil of a quality and viscosity as recommended by the manufacturer of the machine. Theo il characteristics must allow filtering down to 25 microns without it separating. Service : Control periodicaly the lubrication lines to make sure none are broken or crushed and that they are in good condition....
Open the catalog to page 13All BIJUR DELIMON INTERNATIONAL catalogs and technical brochures
-
HIP-P Lubricator
3 Pages
-
HAP-P Lubricator
3 Pages
-
Dynamis Maxx Lubricator
5 Pages
-
DS Series Lubricator
3 Pages
-
Mobile_BR
16 Pages
-
machine tools
12 Pages
-
Industrial Lubrication
16 Pages
-
200 Surefire PDI
28 Pages
-
704
4 Pages
-
VXLO Injecto
3 Pages
-
BL Lubricator
2 Pages
-
DDU Doseur
3 Pages
-
Doseur ZDM
8 Pages
-
Brochure Railway Lubrication
8 Pages
-
Multiport Pump
8 Pages
-
FZ-B Pump
8 Pages
-
M2500 Valves Dividers
19 Pages
-
SA-V Change over valve
4 Pages
-
FD Series Divider Valve
3 Pages
-
DDM & SDM Modular Valves
4 Pages
-
LUBESITE® SYSTEMS
36 Pages
-
DS Series
3 Pages
-
CXL2 Injectors & Manifolds
5 Pages
-
CSK Automatic Lubricator
5 Pages
-
Airmatic® Lubricator
7 Pages
-
AeroFlow Lubricator
4 Pages
-
L-1 Injector
6 Pages
-
DYNAMIS Pump
10 Pages
-
SUREMATIC Pump
10 Pages
-
Railway Lubrication
8 Pages
-
AVH Air/Oil mixing block
4 Pages
-
SA-H Direction control cock
4 Pages
-
SA-G Pressure relief valve
2 Pages
-
DM measuring valve
5 Pages
-
Battery-powered Grease Gun
6 Pages