Airmatic Pump

Airmatic Pump
1 / 21 PagesView full catalog

Airmatic Pump

Product catalog summary
Product Description: The Airmatic pump is a pneumatic device designed for oil feeding in resistance (SLR) or volumetric lubrication systems (PDI). It utilizes a 3/2 way solenoid and compressed air for oil discharge, with a return spring for decompression.
Specifications:
  • Discharge: 2 to 10 ccm per stroke
  • Air inlet pressure: Max 9 Bars
  • Oil pressure: Max 36 Bars
  • Reservoir capacities: 1, 4, or 12 liters
  • Working temperature: 5 to 50°C
  • Lubricant: Mineral oil with viscosity from 30 to 1800 Cst
Ordering Information: Pumps are available with various reservoir capacities and options like low-level switches. Example: AIR4BBA for a 4-liter reservoir with a low-level switch.
Service Instructions:
  • Start-up: Fill the reservoir, connect air supply, and prime the pump.
  • Use clean mineral oil that filters down to 25 microns.
  • Regularly inspect lubrication lines and fittings.
  • Purge air from the lubrication circuit before start-up and after repairs.
Maintenance Kits: Kits are available for different reservoir sizes and pump types, including resistance, volumetric, and injection pumps. Components include gaskets, seals, and check valves.
Special Automotive Versions: Automotive-specific versions feature snap-on connectors and dedicated maintenance kits.
Service Instructions for 12L Reservoir - Special Automotive Version:
  • Start-up: Fill the reservoir, connect air supply, and prime the pump as per the technical data sheet.
  • Oil: Use recommended clean mineral oil, filtering to 25 microns.
  • Service: Regularly check lubrication lines and fittings for damage. Address any excess oil immediately.
  • Important: Purge air from the lubrication circuit before start-up and after repairs.
Spare Parts: Maintenance kits for the AIRMATIC 12L special automotive version are available. For repairs, returning the pump to Bijur Delimon is recommended.
Contact Information: Bijur Delimon has offices in Germany, Spain, France, the UK, India, Ireland, Austria, the USA, and China. Contact details are provided for assistance.
See more

Catalog excerpts

Airmatic Pump-1

Product description Pump AIRMATIC DESCRIPTION A pneumatic pump is designed, depending on the version, to feed oil to resistance (SLR) or volumetric lubrication system (PDI). OPERATION The airmatic is a single action pump piloted by a 3/2 way solenoïd. The oil discharged is released by introducing compressed air into the pump. Oil is sucked into the reservoir as the compressed air in the circuit decompresses with the help of a return spring. For use with volumetric injectors, the pump is equipped with a decompression block wich allows the remainings of the injectors whilst the air circuit is decompressing. Note : Use dry, filtered, lubricated air Principal scheme CHARACTERISTICS Discharge : Air inlet pressure : Air pressure range : Oil pressure : Reservoir capacities : Suction filter : Electric low level switch : Power rating : Cycle frequency : Working temperature : Lubricant to be used : Other lubricant : 1 / 21 2 to 10 ccm / Stroke. 9 Bars max. 4 : 1. 36 Bars max. 1 or 4 liters (plastic). 12 liters (steel). 120 microns. 240 V max. 0.5 A max. Up to 30 cycles per mn. From 5 to 50° max. C Mineral oil viscosity from 30 to 1800 Cst at the working temperature. Contact Bijur Delimon. P_2009_7_Airmatic pump _GB

 Open the catalog to page 1
Airmatic Pump-2

HOW TO ORDER Precise designation and reference using the code below : AIR Pump code A Reservoir capacity 1 1 litre 4 4 litres 12 12 litres Distribution system A 2 Resistance B Volumetric D Injection Option B Low level switch (standard) C Low level switch and snap on refill connector automotive version Example : Airmatic pump with 4 litres reservoir and low level switch for volumetric system, Reference : AIR4BBA. 2 / 21 P_2009_7_Airmatic pump _GB

 Open the catalog to page 2
Airmatic Pump-3

BUUR DELIMON PUMP AIRMATIC WITH ONE LITRE RESERVOIR Item Description Quantity 7 Discharge adjustment screw 1 8 Electrical low level switch 1

 Open the catalog to page 3
Airmatic Pump-4

SERVICE INSTRUCTIONS FOR AIRMATIC PUMP 1L RESERVOIR Start up : Fill the reservoir and connect the air supply. Prime the pump to assure that the system pressurised. Then, follow instructions on the technical date sheet supplied with the unit. Oil : Use only clean mineral oil of a quality and viscosity as recommended by the manufacturer of the machine. Theo il characteristics must allow filtering down to 25 microns without it separating. Service : Control periodically the lubrication lines to make sure none are broken or crushed and that they are in good condition. Ensure all fittings are correctly...

 Open the catalog to page 4
Airmatic Pump-5

BUUR DELIMON MAINTENANCE KIT 1L AIRMATIC PUMP RESERVOIR AND PUMP MAINTENANCE KIT FOR RESISTANCE PUMP Reference Description Quantity Check valve Viton seal RESERVOIR AND PUMP MAINTENANCE KIT FOR VOLUMETRICAL PUMP Check valve Viton seal RESERVOIR AND PUMP MAINTENANCE KIT FOR INJECTION PUMP Reference Description Quantity Check valve Straight connector Viton seal

 Open the catalog to page 5
Airmatic Pump-6

BIJUR DELIMON PUMP AIRMATIC WITH 4 LITRES RESERVOIR 7 Discharge adjustment screw 8 Electrical low level switch

 Open the catalog to page 6
Airmatic Pump-7

SERVICE INSTRUCTIONS FOR AIRMATIC PUMP 4L RESERVOIR Start up : Fill the reservoir and connect the air supply. Prime the pump to assure that the system pressurised. Then, follow instructions on the technical date sheet supplied with the unit. Oil : Use only clean mineral oil of a quality and viscosity as recommended by the manufacturer of the machine. Theo il characteristics must allow filtering down to 25 microns without it separating. Service : Control periodicaly the lubrication lines to make sure none are broken or crushed and that they are in good condition. Ensure all fittings are correctly...

 Open the catalog to page 7
Airmatic Pump-8

MAINTENANCE KIT 4L AIRMATIC PUMP RESERVOIR MAINTENANCE KIT Reference A0284 Description Reservoir gasket Filter element Reservoir screw Guide bar Lockwasher Filling filter Plastic reservoir O ring for filling filter Quantity 1 1 1 2 2 4 1 1 RESERVOIR AND PUMP MAINTENANCE KIT FOR RESISTANCE PUMP Reference Description Quantity A0294 Reservoir maintenance kit Check valve Adaptor Viton seal O ring seal Cup seal Gasket 1 1 1 1 1 1 1 RESERVOIR AND PUMP MAINTENANCE KIT FOR VOLUMETRICAL PUMP Description Quantity Reservoir maintenance kit Control unit CTN5 Check valve Viton seal O ring seal Cup seal Gasket...

 Open the catalog to page 8
Airmatic Pump-9

BIJUR DELIMON PUMP AIRMATIC WITH 12 LITRES RESERVOIR 7 Discharge adjustment screw

 Open the catalog to page 9
Airmatic Pump-10

SERVICE INSTRUCTIONS FOR AIRMATIC PUMP 12L RESERVOIR Start up : Fill the reservoir and connect the air supply. Prime the pump to assure that the system pressurised. Then, follow instructions on the technical date sheet supplied with the unit. Oil : Use only clean mineral oil of a quality and viscosity as recommended by the manufacturer of the machine. Theo il characteristics must allow filtering down to 25 microns without it separating. Service : Control periodicaly the lubrication lines to make sure none are broken or crushed and that they are in good condition. Ensure all fittings are correctly...

 Open the catalog to page 10
Airmatic Pump-11

MAINTENANCE FOR RESERVOIR KIT 12L RESERVOIR MAINTENANCE KIT Reference A0285 Description Reservoir gasket Filter element Reservoir screw Lockwasher Filling filter Seal for oil sump plug Sight glass Quantity 1 1 8 8 1 1 1 RESERVOIR AND PUMP MAINTENANCE KIT FOR RESISTANCE PUMP Reference Description Quantity A0297 Reservoir maintenance kit Check valve Adaptor Viton seal O ring seal Cup seal Gasket 1 1 1 1 1 1 1 RESERVOIR AND PUMP MAINTENANCE KIT FOR VOLUMETRICAL PUMP Description Quantity Reservoir maintenance kit Control unit CTN5 Check valve Viton seal O ring seal Cup seal Gasket 1 1 1 1 1 1 1 RESERVOIR...

 Open the catalog to page 11
Airmatic Pump-12

Item Description Quantity 7 Discharge adjustment screw 1 8 Electrical low level switch 1

 Open the catalog to page 12
Airmatic Pump-13

SERVICE INSTRUCTIONS FOR PUMP WITH 1L RESERVOIR SPECIAL AUTOMOTIVE VERSION Start up : Fill the reservoir and connect the air supply. Prime the pump to assure that the system pressurised. Then, follow instructions on the technical date sheet supplied with the unit. Oil : Use only clean mineral oil of a quality and viscosity as recommended by the manufacturer of the machine. Theo il characteristics must allow filtering down to 25 microns without it separating. Service : Control periodicaly the lubrication lines to make sure none are broken or crushed and that they are in good condition. Ensure...

 Open the catalog to page 13
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.