ASi-5/ASi-3 EtherNet/IP + Modbus TCPGateway with integrated Safety Monitor
5Pages

{{requestButtons}}

Catalog excerpts

ASi-5/ASi-3 EtherNet/IP + Modbus TCPGateway with integrated Safety Monitor - 1

ASi-5/ASi-3 EtherNet/IP + Modbus TCPGateway with integrated Safety Monitor ASi-5 – Great data bandwidth, short cycle times Compatible with all ASi generations CIP Safety over EtherNet/IP and Safe Link in one device 2 ASi-5/ASi-3 masters, EtherNet/IP + Modbus TCP device • switch integrated • up to 6 release circuits SIL 3, cat. 4 on the Monitor, electronic safe outputs (figure similar) Safe ASi outputs are supported • up to 64 independent ASi outputs Multiple safe ASi outputs possible via a single ASi address OPC UA server and integrated web server for simplified diagnostics Safe speed and standstill monitoring Applications up to category 4/PLe/SIL 3 Chip card for storage of configuration data Fieldbus Interface Safety com- Inputs munication Safety, SIL 3, cat. 4 Outputs Inputs Safety, SIL 3, Safety, cat. 4 expandable to max. 62 x 6 release CIP Safety EtherNET/IP 2 channels, 3x circuits; over + Modbus max. 1922 in EtherNet/IP + 2 channels 6 x electronic TCP, OPC UA max. configsafe outputs Safe Link uration Safety outputs, independent according to SIL 3, expandable to max. 64, max. 1984 in max. configuration Number of ASi networks, number of ASi Master (1) Integrated decoupling, ASi current measurement in the gateway (2) 2 ASi networks, yes, max. 2 ASi-5/ASi-3 4 A/ASi network Masters Diagnostic Art. no. and configuration interface (3) Ethernet fieldbus, Ethernet diagnostic Number of ASi networks, number of ASi Master "Double Master": 2 ASi networks, 2 ASi-5/ASi-3 Masters. Integrated decoupling, ASi current measurement in the gateway "yes, max. 4 A/ASi network": Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply). Operation with short cable lengths with standard 24 V power supply possible. "no, max. 8 A/ASi network, redundant supply": 1 power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies. Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate. Diagnostic and configuration interface "Ethernet fieldbus + Ethernet diagnostic": Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface The latest version of the device description file of the gateway is available in the "Downloads" section of the respective device. Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de www.bihl-wiedemann.de We reserve the right to change any data Mannheim, 19.

Open the catalog to page 1
ASi-5/ASi-3 EtherNet/IP + Modbus TCPGateway with integrated Safety Monitor - 2

ASi-5/ASi-3 EtherNet/IP + Modbus TCPGateway with integrated Safety Monitor Article no. Fieldbus interface Type Baud rate OPC UA interface Variably configurable Assembly Objects Function Card slot Ethernet interface Type Baud rate OPC UA interface Safety communication Safe coupling (1) ASi ASi specification Cycle time BWU3857 Ethernet + Modbus TCP acc. to IEEE 802.3 2 x RJ-45, integrated 2-Port-Switch 10/100 MBaud OPC UA server + web server yes Device Level Ring (DLR) (Ethernet/IP only) chip card (512 KB) for storage of configuration data Ethernet; RJ-45 acc. to IEEE 802.3 10/100 MBaud...

Open the catalog to page 2
ASi-5/ASi-3 EtherNet/IP + Modbus TCPGateway with integrated Safety Monitor - 3

ASi-5/ASi-3 EtherNet/IP + Modbus TCPGateway with integrated Safety Monitor Article no. Environment Applied standards Operating altitude Ambient temperature Storage temperature Housing Pollution Degree Protection category Tolerable loading referring to humidity Maximum tolerable shock and vibration stress Voltage of insulation Weight Dimensions (W / H / D in mm) BWU3857 EN 60529 EN 61000-6-2 EN 61000-6-4 EN 62061, SIL 3 EN 61508, SIL 3 EN ISO 13849-1, PLe 2000 m -25 °C … +55 °C (no condensation permitted) -25 °C … +85 °C stainless steel, for DIN rail mounting 2 IP20 according to EN 61131-2...

Open the catalog to page 3
ASi-5/ASi-3 EtherNet/IP + Modbus TCPGateway with integrated Safety Monitor - 4

ASi-5/ASi-3 EtherNet/IP + Modbus TCPGateway with integrated Safety Monitor (2) connection only at terminals SO1 ... SO6 configured as standard inputs (see “Variations of terminal configuration for BWU3857”) see “Variations of terminal configuration for BWU3857” BWU3857 Derating output current IAUX [A] 7,2 Operating current Article no. master power supply, approx 300 mA out of ASi network master power supply, max. 300 mA out of ASi circuit 1 (approx. 70 mA ... 300 mA), max. 300 mA out of ASi circuit 2 (approx. 70 mA ... 300 mA); in sum max. 370 mA Cost-effective power for 2 ASi networks with...

Open the catalog to page 4
ASi-5/ASi-3 EtherNet/IP + Modbus TCPGateway with integrated Safety Monitor - 5

ASi-5/ASi-3 EtherNet/IP + Modbus TCPGateway with integrated Safety Monitor Variations of terminal configuration for BWU3857 Terminal Safe output Safe input for mechanical contacts in combination with T1, T2 (1) Safe antivalent input (1) Safe electronic input (1) Inputs may only be supplied by the same 24 V source as the device itself. If outputs are configured as inputs, the input current has to be limited by an external element at ≤ 100 mA. Connections: Gateway + Safety Monitor: BWU3857 T2 Description Safe input terminal (T1) Safe input terminal (T2) Clock output 1 Clock output 2 Safe...

Open the catalog to page 5