ASi-3 BACnet/IP Gateway with integrated Safety Monitor
5Pages

{{requestButtons}}

Catalog excerpts

ASi-3 BACnet/IP Gateway with integrated Safety Monitor - 1

ASi-3 BACnet/IP Gateway with integrated Safety Monitor 2 ASi-3 master, BACnet B-ASC Up to 64 release circuits • up to 6 release circuits SIL 3, cat. 4 on the Monitor, electronic safe outputs Safe ASi outputs are supported • up to 64 independent ASi outputs Multiple safe ASi outputs possible via a single ASi address OPC UA server and integrated web server for simplified diagnostics Safe speed and standstill monitoring (figure similar) Applications up to category 4/PLe/SIL 3 Chip card for storage of configuration data Safety com- Inputs munication Safety, SIL 3, cat. 4 BACnet/IP, Safe Link OPC UA Inputs Safety, expandable to Safety outputs, independent according to SIL 3, expandable to Number of ASi networks, number of ASi Master (2) Integrated decoupling, ASi current measurement in the gateway (3) Diagnostic Art. no. and configuration interface (4) 6 release circuits; 6 x electronic safe outputs Ethernet fieldbus, yes, max. 8A/ASi network Ethernet diagnostic Fieldbus interface Communication interface between fieldbus and gateway: interfaces for standardized fieldbus systems in industrial automation. BACnet/IP ASi gateway: interface for a BACnet/IP fieldbus OPC UA server: interface for the OPC UA communication. Number of ASi networks, number of ASi Master “Double Master”: 2 ASi networks, 2 ASi-3 Masters. Integrated decoupling, ASi current measurement in the gateway “yes, max. 8 A/ASi network”: Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply). Operation with short cable lengths with standard 24 V power supply possible. Diagnostic and configuration interface “Ethernet fieldbus + Ethernet diagnostic”: Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface The latest version of the device description file of the gateway is available in the "Downloads" section of the respective device. Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de www.bihl-wiedemann.de We reserve the right to change any data Mannh

Open the catalog to page 1
ASi-3 BACnet/IP Gateway with integrated Safety Monitor - 2

ASi-3 BACnet/IP Gateway with integrated Safety Monitor Article no. Fieldbus interface Type Baud rate Safety communication OPC UA interface Function Card slot Diagnostic interface Type Baud rate Safety communication OPC UA interface ASi ASi specification Number of ASi networks, number of ASi Master Cycle time Operating voltage BWU4780 BACnet/IP acc. to EN ISO 16484-5; 2 x RJ-45 acc. to IEEE 802.3, integrated 2-Port-Switch, 100 MBaud Safe Link OPC UA server + web server BACnet B-ASC chip card (16 GB) for storage of configuration data Ethernet RJ-45 acc. to IEEE 802.3 10/100 MBaud half-duplex...

Open the catalog to page 2
ASi-3 BACnet/IP Gateway with integrated Safety Monitor - 3

ASi-3 BACnet/IP Gateway with integrated Safety Monitor Article no. Environment Standards Operating altitude Ambient temperature Storage temperature Housing Pollution Degree Protection category Tolerable loading referring to humidity Maximum tolerable shock and vibration stress Voltage of insulation Weight Dimensions (W / H / D in mm) (1) BWU4780 EN 62026-2 EN 60529 EN 61000-6-2 EN 61000-6-4 EN 61131-2 EN 61326-3-1 EN 50581 EN 62061, SIL 3 EN 61508, SIL 3 EN ISO 13849-1, PLe EN ISO 13849-2 2000 m -25 °C … +55 °C (no condensation permitted) -25 °C … +85 °C stainless steel, for DIN rail...

Open the catalog to page 3
ASi-3 BACnet/IP Gateway with integrated Safety Monitor - 4

ASi-3 BACnet/IP Gateway with integrated Safety Monitor Article no. Output Number of release circuits on the monitor Outputs Power supply (semiconductor outputs) Output Test pulse (semiconductor outputs) max. contact load: 1,2 ADC-13 at 30 V, ∑ = 7,2 A in sum (5) out of AUX short-circuit and overload protected according to EN 61131-2 if output is on: minimum interval between 2 test pulses: 250 ms; maximum pulse width 1 ms connection at all SI or SO terminals possible. connection only at terminals SO1 ... SO6 configured as standard inputs (see “Variations of terminal configuration for...

Open the catalog to page 4
ASi-3 BACnet/IP Gateway with integrated Safety Monitor - 5

ASi-3 BACnet/IP Gateway with integrated Safety Monitor Variations of terminal configuration for BWU4780 Terminal Safe output Safe input for mechanical contacts in combination with T1, T2 (1) Safe antivalent input (1) Safe electronic input (1) Inputs may only be supplied by the same 24 V source as the device itself. If outputs are configured as inputs, the input current has to be limited by an external element at ≤ 100 mA. Connections: Gateway + Safety Monitor: BWU4780 T2 safe inputs/ Description Safe input terminal (T1) Safe input terminal (T2) Clock output 1 Clock output 2 Safe...

Open the catalog to page 5