Individual climate control Fan coil units Model DECO

Open the catalog to page 1
Model DECO - 2

Fan coil units Comfortable indoor climate In buildings, pleasant working and living conditions are to a large degree determined by the indoor climate. A comfortable climate in a room will not go by unnoticed by staff and visitors and will give them a pleasant feeling. Added to that, a comfortable working climate will reduce the absenteeism rate among your employees and increase both their productivity and your ultimate return on investment. The Biddle fan coil unit, model DECO, gives you optimum control of the indoor climate by heating, cooling and/or ventilating the room to your own...

Open the catalog to page 2
Model DECO - 3

Optional accessories: various controls The unit can incorporate an airside controller or a combined air- and waterside controller, either option having the corresponding easy-to-use control panel. The controller provides for efficient heating and cooling at the lowest possible noise level. The controller comes standard with a weekly timer and a room thermostat and can also be combined with, for instance, a CO2 sensor, (see page 7). With a CO2 sensor the volume of fresh air can be tailored to the use of the room. Comfort where you need it Adjustable outlet grille The air is discharged...

Open the catalog to page 3
Model DECO - 4

Various models People prefer climate control equipment that is unobtrusive and fits in with its surroundings. That’s why Biddle has devoted much attention to the outward appearance of the fan coil unit, so it will fit in with any interior. As each room asks for a solution of its own, Biddle offers a wide and complete range of fan coil units (± 10.000 variants). Ceiling model (Business) Model with casing This model is available either as a wall model (F) or as a ceiling model (C) and can be freely standing or suspended. The next units are available: 1. Stylish model (S): with curved plastic...

Open the catalog to page 4
Model DECO - 5

Many options Typecode DECO 75-H1C3-R-FS12 Unit size 50 = 140 - 605 m3/h 75 = 180 - 860 m3/h 100 = 275 - 1180 m3/h 125 = 300 - 1400 m3/h 150 = 390 - 1800 m3/h Coil type H1, H2, H4 = Water heating C2, C3, C4 = Water cooling H1C3 = Water heating and cooling HE = electric heating (1,2,3,4 = number of rows) Water connections R = right L = left HE electrical connection on the = left side. Model type FS = floor model: stylish FB = floor model: business CS = ceiling model: stylish CB = ceiling model: business FR = recessed Floor model CR = recessed ceiling model 2 - 12 = see figure 1: model types...

Open the catalog to page 5
Model DECO - 6

Standard delivery Units with casing come with: • adjustable discharge grille • removable air filter • integrated condensate draining pump (only in ceiling model with cooling mode) • integrated frost-protection device and damper control (only in ventilation model) • condensate tray (only in models with cooling mode) Recessed units come with: • removable air filter • frost-protection device (only in ventilation model) • condensate tray (only in models with cooling mode) Adjustable discharge grille Accessories The following control accessories are available (see page 7): • air side controller...

Open the catalog to page 6
Model DECO - 7

Control options Model DECO is available with three types of control, in order to make it suitable for every project. 1. Basic (without control): The fan coil unit (only the recirculation model) is provided with a transformer and is wired in a fixed speed. 2. Airside control This controller regulates the fan speed (3 speeds) to achieve the desired room temperature. 3. Combined air- and waterside controller This controller regulates both the fan speed and the discharge air temperature to achieve the desired room temperature. The ventilation unit is delivered with the combined controller....

Open the catalog to page 7
Model DECO - 8

Technical data DECO 50 Installation data electric supply max. running current max. consumed power General selection data tapping voltage power consumption, fans input power, fans air displacement sound level * The control system limits the air discharge temperature to 50°C. This limitation is not included in the selection data. ** Water pressure loss, exclusive three- or two- way valve. For sft-values of three- or two-way valve, see page 22.

Open the catalog to page 8
Model DECO - 9

Technical data DECO 75 Installation data electrical supply max. running current max. consumed power General selection data tapping voltage power consumption, fans input power, fans displacement sound level * The control system limits the air discharge temperature to 50°C. This limitation is not included in the selection data. ** Water pressure loss, exclusive three- or two- way valve. For sft-values of three- or two-way valve, see page 22.

Open the catalog to page 9
Model DECO - 10

Technical data DECO 100 Installation data electrical supply max. running current max. consumed power General selection data tapping voltage power consumption, fans input power, fans air displacement sound level * The control system limits the air discharge temperature to 50°C. This limitation is not included in the selection data. ** Water pressure loss, exclusive three- or two- way valve. For sft-values of three- or two-way valve, see page 22.

Open the catalog to page 10
Model DECO - 11

Technical data DECO 125 Installation data electrical supply max. running current max. consumed power General selection data tapping voltage power consumption, fans input power, fans air displacement sound level * The control system limits the air discharge temperature to 50°C. This limitation is not included in the selection data. ** Water pressure loss, exclusive three- or two- way valve. For sft-values of three- or two-way valve, see page 22.

Open the catalog to page 11
Model DECO - 12

Technical data DECO 150 Installation data electrical supply max. running current max. consumed power General selection data tapping voltage power consumption, fans input power, fans air displacement sound level * The control system limits the air discharge temperature to 50°C. This limitation is not included in the selection data. ** Water pressure loss, exclusive three- or two- way valve. For sft-values of three- or two-way valve, see page 22.

Open the catalog to page 12
Model DECO - 13

Technical data DECO HE Installation data electrical supply max. running current A max. consumed power kW heating* * With electric heating, the heating capacity is 5% lower than the installed power.

Open the catalog to page 13

All Biddle catalogs and technical brochures

  1. INDAC2

    32 Pages

  2. DX AIR CURTAIN

    28 Pages

  3. SENSAIR

    52 Pages

  4. Model NOZ

    20 Pages

  5. Model MAT

    8 Pages

  6. Model DoorFlow

    16 Pages

  7. Model CITY

    12 Pages

  8. Model IndAC

    20 Pages

  9. Invisidor CA2

    20 Pages

Archived catalogs

  1. Invisidor CITY

    12 Pages

  2. Model SF

    8 Pages