Catalog excerpts

UPSI-IP-2 Series12 VDC / 8 A | 24 VDC / 6 A © Outdoor DC/DC UPS for extreme environments © Protection class IP67 © Robust aluminium housing © Based on UPSI-1208/2406 technology © For temperatures up to +70 °C © LiFePO4 or Supercap packs as energy storage already included © Stored energy up to 99 Wh (LiFePO4) © Optional wide-range input available © External mounting brackets pre-assembled © Pressure compensation element and data interface included Overview P/N Input voltage* Output current / power *Values measured from/to input/output connector Please note that using long input/output cables can cause a high voltage drop over these cables. Make sure that your DC source supplies enough voltage to compensate this drop-out voltage. Product specific data Battery monitoring Battery test is executed in normal mode Shutdown detection Via load sensor Reboot function Reboot function and time can be configured by software Load sensor Configurable via UPSI HID-Battery-Parameter software (download at www.bicker.de) UPS shuts down after 15 sec, if connected load decreases below set value and UPS is being in battery mode Timer function Configurable via UPSI HID-Battery-Parameter software in steps of single seconds (3600 sec max) Warranty 3 years warranty For LiFePO4 versions: only 1 year for the energy source Bicker Elektronik GmbH | 86609 Donauworth | Germany Tel. +49 906 70595-0 | info@bicker.de | www.bicker.de
Open the catalog to page 1
*Values measured from/to input/output connector DC UPS Ambient temperature [°C]Vin: 7-8 VDC 8-9 VDC ■ 9-36 VDC 4ftBICKER.de ELEKTRONIK Bicker Elektronik GmbH | 86609 Donauworth | Germany Tel. +49 906 70595-0 | info@bicker.de | www.bicker.de
Open the catalog to page 2
UPS systems Backup time UPSI-1208IP-23U/-23UW Nominal backup time vs. POUT Nominal backup time vs. Pout , calculated, 21 °C 600 550 500 450 Pout [W] Output Power DC UPS Bicker Elektronik GmbH | 86609 Donauwörth | Germany Tel. +49 906 70595-0 | info@bicker.de | www.
Open the catalog to page 3
*Values measured from/to input/output connector DC UPS Ambient temperature [°C]Vin: 8-10 VDC ■ 10-12 VDC ■ 12-36 VDC 4ftBICKER.de ELEKTRONIK Bicker Elektronik GmbH | 86609 Donauworth | Germany Tel. +49 906 70595-0 | info@bicker.de | www.bicker.de
Open the catalog to page 4
Backup time UPSI-2406IP-24U Nominal backup time vs. Pout , calculated, 21 °C OJ n Backup time [s] Backup time [s] Bicker Elektronik GmbH | 86609 Donauworth | Germany Tel. +49 906 70595-0 | info@bicker.de | www.bicker.de
Open the catalog to page 5
*Values measured from/to input/output connector DC UPS Ambient temperature [°C]Vin: 8-10 VDC ■ 10-12 VDC ■ 12-36 VDC 4ftBICKER.de ELEKTRONIK Bicker Elektronik GmbH | 86609 Donauworth | Germany Tel. +49 906 70595-0 | info@bicker.de | www.bicker.de
Open the catalog to page 6
Bicker Elektronik GmbH | 86609 Donauworth | Germany Tel. +49 906 70595-0 | info@bicker.de | www.bicker.de
Open the catalog to page 7
UPS systems DC connector 1 1 Input (+) 2 Input (-) 3 n.c. 4 FG DC connector 2 1 Output (+) 2 Output (-) 3 n.c. 4 FG USB interface connector 1 Data (-) 2 +5 V 3 GND 4 Shielding 5 Data (+) Connector Description Manufacturer Part No. DC connector 1 (case side) for VIN RD24 flange plug, poles 3+PE Binder Connector 09 4223 150 04 DC connector 2 (case side) for VOUT RD24 flange socket, poles 3+PE Binder Connector 09 4224 00 04 USB interface connector (case side) Snap-in flange socket, 5 poles Binder Connector 99 9116 00 05 DC counter connector 1 (cable side) RD24 cable socket, poles 3+PE Binder...
Open the catalog to page 8
Description Input cable, 3m, open end, 2.5 mm2 Output cable, 3m, open end, 2.5 mm2 USB/USB-HID interface cable, 3 m, USB type A plug Specification is subject to change without notice. Errors excepted. Status as at: 23.10.2019 Safety information and notes Please consider to each country’s own regulation about recycling and disposal of used batteries etc. in hazardous waste or resending to any recycling organization. The device including the battery pack should not be exposed to fire, immersed under water, opened, short-circuited, reversed or overheated. During storage it should not be...
Open the catalog to page 9All Bicker Elektronik GmbH catalogs and technical brochures
-
UPS-1000-B1
32 Pages
-
BE-DCEB5A
2 Pages
-
BE-DCEB10A
2 Pages
-
DC300WS
19 Pages
-
BP-LFP-13250S
18 Pages
-
BP-LFP-10250S
18 Pages
-
BP-LFP-1325S
19 Pages
-
BP-LFP-1025S
19 Pages
-
DC2412-UPSP2
9 Pages
-
UPSI-2406IP-38AC
31 Pages
-
BP-LFP-2725D
22 Pages
-
BP-LFP-2725
22 Pages
-
BP-LFP-1375D
5 Pages
-
BP-LFP-1375
5 Pages
-
BDCD-50xxC/T series
4 Pages
-
UPSI-2412DP2
31 Pages
-
UPSI-2412D
31 Pages
-
UPSI-2406
3 Pages
-
UPSI-2412
31 Pages
-
BDCD-30CT SERIES
4 Pages
-
BDC-30CT SERIES
4 Pages
-
BDCD-10CT SERIES
4 Pages
-
BDC-10CT SERIES
4 Pages
-
BDCD-30VC SERIES
4 Pages
-
BDC-30VC SERIES
4 Pages
-
BDCD-10VC SERIES
4 Pages
-
DC161W
5 Pages
-
BEO-1400M SERIES
5 Pages
-
BEP-520C
4 Pages
-
BEO-3000MC SERIES
4 Pages
-
BEO-2000MC SERIES
4 Pages
-
BET-1600M SERIES
3 Pages
-
BET-1500 SERIES
3 Pages
-
BET-1000M SERIES
3 Pages
-
BET-0900-T SERIES
6 Pages
-
BET-0600M SERIES
3 Pages
-
BET-0600 SERIES
3 Pages
-
UPSI-1208IP-11U
4 Pages
-
IUPS-401
3 Pages
-
DC2412-UPS
6 Pages
-
UPSIC-2403
5 Pages
-
UPSIC-1205
5 Pages
-
UPSI-1208DP2
27 Pages
-
UPSI-2406DP2
27 Pages
-
UPSI-2406DP1
27 Pages
-
UPSI-2406D
3 Pages
-
UPSI-1208
3 Pages
-
BES-540T
2 Pages
-
BES-540C
2 Pages
-
BEH-542C
3 Pages
-
BEA-750H
4 Pages
-
BEA-550K
4 Pages
-
BEA-630
2 Pages
-
BEP-530H
3 Pages
-
BEP-520H
3 Pages
-
BEP-510
3 Pages
-
BDC-10VC SERIES
4 Pages
-
DC160WS
5 Pages
-
BEO-0800 SERIES
4 Pages
-
DC160W
4 Pages
-
DC1224
2 Pages