Fanless Delivery 24 V DC / 6 A 24V DC UPS (DIN rail version) Intelligent power sharing Regulated output voltage Min. load disconnect Battery disconnect Power fail timer External signal shutdown Battery hot swap Reboot function Fuel gauge NEW Also available as open frame version UPSI-2406 Product specific data Battery monitoring Shutdown detection Reboot function Load sensor Timer function External signal shutdown Backup time Relay 24 V DC (22.5…29 V) 7.5 A max. Normal mode: Vin– 0.3 V (Full load) Backup: 23.5 V DC 6 A max. 3 A max. on input CC / CV / CP Deep discharge protection Overcurrent protection Reverse polarity protection USB, RS232, USB-HID LiFePO4, Supercaps CE Operating: -20…+70 °C / Storage: -20…+70 °C Backup mode: +55…+70 °C, 100 mA (2.35 W) / °C 5000 m 1500 m operation altitude or higher: 5.7 W / 500 m or reduction of operation temperature of 3.5 °C / 500 m Operating: 10…85 % RH, non-condensing / Storage: 10…90 % RH, non-condensing 36 x 100 x 120 mm ±0.5 mm 0.25 kg Battery test is executed in normal mode Via load sensor Reboot function and time can be configured by software Configurable via UPSI HID-Battery-Parameter software (download at www.bicker.de) UPS shuts down after 15 sec, if connected load decreases below set value and UPS is being in battery mode Configurable via UPSI HID-Battery-Parameter software in steps of single seconds (3600 sec max) UPS can be configured to shut down on external signal (e.g. ignition) with delay set in steps of single seconds (3600 sec max) See datasheets of battery packs Dry contact on power fail (Normal mode: open / Backup mode: closed) Relay switching current max 0.5 A @ 125 V AC / 1 A @ 24 V DC Bicker Elektronik GmbH | 86609 Donauwörth | Germany Tel. +49 906 70595-0 | [email protected] | www.bicker.de Input voltage Input current Output voltage Output current Battery charge current nom. Charging method Protection Interface Type of battery Safety / EMC Temperature Derating (depending on temperature) Max. operation altitude Derating (dependi
Open the catalog to page 1Bicker Elektronik GmbH | 86609 Donauworth | Germany Tel. +49 906 70595-0 | [email protected] | www.bicker.de
Open the catalog to page 2Battery packs and Backup time for UPSI-2406D Nominal backup time, measured at +21 °C 50 W 100 W Back up time depends on battery capacitance, load and temperature. At very high or low temperatures a reduction of backup time occurs. Larger capacities on request. P/N explanation battery packs BP - XXX - YYZZD Battery Pack LFP = LiFePO4 YY Approx. nom. V SUC = Supercaps ZZ Capacitance (LiFePO4 in 10-1 Ah) or useful energy (Supercaps in 10-1 kJ) Example: BP-LFP-1325D BP Battery Pack LFP Storage medium: LiFePO4 Scope of delivery Quantity Description Specification is subject to change without notice....
Open the catalog to page 320 Pages
45 Pages
45 Pages
31 Pages
31 Pages
31 Pages
31 Pages
38 Pages
38 Pages
32 Pages
2 Pages
2 Pages
18 Pages
18 Pages
19 Pages
19 Pages
9 Pages
31 Pages
22 Pages
22 Pages
5 Pages
5 Pages
4 Pages
31 Pages
3 Pages
31 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
5 Pages
5 Pages
4 Pages
4 Pages
4 Pages
3 Pages
3 Pages
3 Pages
6 Pages
3 Pages
3 Pages
9 Pages
4 Pages
3 Pages
6 Pages
5 Pages
5 Pages
27 Pages
3 Pages
2 Pages
2 Pages
3 Pages
4 Pages
4 Pages
2 Pages
3 Pages
3 Pages
3 Pages
4 Pages
5 Pages
4 Pages
4 Pages
2 Pages