UPSI-IP-1 Series12 VDC / 8 A | 24 VDC / 6 A © Outdoor DC/DC UPS for extreme environments © Protection class IP67 © Robust aluminium housing © Based on UPSI-1208/2406 technology © For temperatures up to +50 °C © LiFePO4 packs as energy storage already included © Stored energy up to 33 Wh © External mounting brackets pre-assembled © Pressure compensation element and data interface included © Shock and vibration test according to DIN 60068-2 Technical data *Values measured from/to input/output connector Please note that using long input/output cables can cause a high voltage drop over these cables. Make sure that your DC source supplies enough voltage to compensate this drop-out voltage. 3 years warranty For LiFePO4 versions: only 1 year for the energy source Bicker Elektronik GmbH | 86609 Donauworth | Germany Tel. +49 906 70595-0 | [email protected] | www.bicker.de
Open the catalog to page 1UPS systems Backup time UPSI-1208IP-11U Nominal backup time vs. P out BP-LFP-1025(D): Backup (me nominal vs. Pout Nominal backup time vs. P out BP-LFP-1325(D): Backup (me nominal vs. Pout Bicker Elektronik GmbH | 86609 Donauwörth | Germany Tel. +49 906 70595-0 | [email protected] | www
Open the catalog to page 2OUT- (black 2) -o -o OUT+ (black 1) DC connector 1 1 Input (+) 2 Input (-) 3 n.c. 4 FG DC connector 2 1 Output (+) 2 Output (-) 3 n.c. 4 FG USB interface connector 1 Data (-) 2 +5 V 3 GND 4 Shielding 5 Data (+) Connector Description Manufacturer Part No. DC connector 1 (case side) for VIN RD24 flange plug, poles 3+PE Binder Connector 09 4223 150 04 DC connector 2 (case side) for VOUT RD24 flange socket, poles 3+PE Binder Connector 09 4224 00 04 USB interface connector (case side) Snap-in flange socket, 5 poles Binder Connector 99 9116 00 05 DC counter connector 1 (cable side) RD24 cable socket,...
Open the catalog to page 3Product specific data Specification is subject to change without notice. Errors excepted. Status as at: 25.09.2019 Battery monitoring Battery test is executed in normal mode Shutdown detection Via load sensor Reboot function Reboot function and time can be configured by software Load sensor Configurable via UPSI HID-Battery-Parameter software (download at www.bicker.de) UPS shuts down after 15 sec, if connected load decreases below set value and UPS is being in battery mode Timer function Configurable via UPSI HID-Battery-Parameter software in steps of single seconds (3600 sec max) Quantity Description...
Open the catalog to page 420 Pages
45 Pages
45 Pages
31 Pages
31 Pages
31 Pages
31 Pages
38 Pages
38 Pages
32 Pages
2 Pages
2 Pages
18 Pages
18 Pages
19 Pages
19 Pages
9 Pages
31 Pages
22 Pages
22 Pages
5 Pages
5 Pages
4 Pages
31 Pages
3 Pages
31 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
5 Pages
5 Pages
4 Pages
4 Pages
4 Pages
3 Pages
3 Pages
3 Pages
6 Pages
3 Pages
3 Pages
9 Pages
3 Pages
6 Pages
5 Pages
5 Pages
27 Pages
3 Pages
3 Pages
2 Pages
2 Pages
3 Pages
4 Pages
4 Pages
2 Pages
3 Pages
3 Pages
3 Pages
4 Pages
5 Pages
4 Pages
4 Pages
2 Pages