DC300WS - 1

DC /DC 300W POWER SUPPLY Bicker Elektronik GmbH Ludwig-Auer-Straße 23 | 86609 Donauwörth · G

Open the catalog to page 1
DC300WS - 2

Legend of used symbols Symbol Description Attention! Important hazard warning. Do not dispose of in the domestic waste. Warning of electrical voltage. Revision Directory Date Initial version Release version

Open the catalog to page 2
DC300WS - 3

DC300WS Powerful DC/DC converter with 300 W output power from 6–36 V  Ultra wide input range 6…36 V DC  Adjustable ourput voltage +12 V, +19 V or +24 V DC  Very compact design  Full power in extended temperature range -20...+60°C  High efficiency up to 98 %  More than 10 years capacitor lifetime  Optional compensation of the output voltage via sense lines  Optional Remote On/Off Te ch n i c a l Data Input voltage Input current Output voltages Max. output current Max. output power Capacitive load Protection Derating Ambient temperature Operating altitude Max. permitted humidity...

Open the catalog to page 3
DC300WS - 5

B  Introduction and description Read carefully before initial operation! This manual shall help the user to get familiar with the product and its components and features. It shall provide information as accurately and completely as possible. The manual as well as all documents has to be read and followed strictly before installation. Otherwise warranty and guarantee can be cancelled partly or completely. Any liability on the part of Bicker Elektronik is excluded for possible existing errors as well as non-compliance with the instructions for use and installation. B1  Description of the...

Open the catalog to page 5
DC300WS - 6

WARNING! Disregarding of following issues can result in electric shock, fire, serious injury or death. 1. Care must be taken to ensure proper and professional wiring. 2. The device pack must not be exposed to fire and temperatures outside the specification. 3. The device must not be immersed in water or exposed to splash water. 4. The device must not be operated in a humid environment or in an environment where dew and condensation are to be expected. 5. The device must not be opened, overheated or otherwise soldered / welded. 6. Changes or attempts to repair the device are to be omitted....

Open the catalog to page 6
DC300WS - 7

D  Technical Data D1 General Technical Data INPUT DATA Unless otherwise stated, all specifications apply to +25 °C ambient temperature, 6–36 V DC input voltage and nominal output current (IN). Input voltage Input voltage range Approximate current consumption @ 300 W output power UIN = 12 V UIN = 19 V UIN = 24 V UIN = 36 V Internal input fuse Standby consumption J5 1-2: PSON (J6) active; PSON (J6) short-circuit = on J5 2-3: PSON (J6) inactive, permanent on Switch-on time under voltage: 5 V over voltage: 39 V active reverse polarity Insulation voltage

Open the catalog to page 7
DC300WS - 8

OUTPUT DATA Unless otherwise stated, all specifications apply to +25 °C ambient temperature, 6–36 V DC input voltage and nominal output current (IN). Output voltage Output voltage tolerance Capacitive load Maximum output current UOUT = 12 V UOUT = 19 V UOUT = 24 V Ripple & Noise Output power Short circuit Over current >41 A Over voltage >28 V CONNECTION DATA INPUT (J7, J8) / OUTPUT (J1, J2) Connection method Conductor cross-section solid Conductor cross-section flexible 12 … 14 AWG / 3.3…2.08 mm² Ring or fork cable lug Conductor cross-section with ferrule Stripping length Tightening torque...

Open the catalog to page 8
DC300WS - 9

GENERAL DATA Flammability class according to UL 94 (housing / terminal blocks) HOUSING Degree of protection Protection class Mounting type Housing version ENVIRONMENTAL CONDITIONS Ambient temperature (operation) Ambient temperature (start up without load) -30 °C Ambient temperature (storage / transport) Operating: 10…90 % RH, non-condensing Storage: 10…95 % RH, non-condensing Operating altitude Climate class STANDARDS Safety extra-low voltage

Open the catalog to page 9
DC300WS - 10

INTERFERENCE IMMUNITY ACCORDING TO EN 61000 (INDUSTRY) Basic standard CE Fulfilled requirements according to EN 61000 (CE) (Interference immunity of industrial environment) Electrostatic discharge EN 61000-4-2 Contact discharge Air discharge Comment Fast transients (Burst) EN 61000-4-4 Test voltage Comment Surge voltage load (Surge) EN 61000-4-5 Test voltage L–N Test voltage L–PE, N–PE Comment EMISSION ACCORDING TO EN 55016-2-3 (DOMESTIC) Basic standard CE Fulfilled requirements according to EN 55016-2-3 (CE) (Domestic) Conducted emission from the power port EN 55016-2-3 Frequency range...

Open the catalog to page 10
DC300WS - 11

: Temperature directly at the components

Open the catalog to page 11
DC300WS - 12

: Temperature directly at the components

Open the catalog to page 12
DC300WS - 13

Unless otherwise stated, Tolerance according to: DIN ISO 2768 T1 - m DIN ISO 2768 T2 - K E  Name / Address / Support E-Mail / Phone number of the manufacturer Bicker Elektronik GmbH · Ludwig-Auer-Straße 23 · 86609 Donauwörth · Germany E-Mail: support@bicker.de · Tel.: +49 (0) 906 70595-0

Open the catalog to page 13
DC300WS - 14

F  General Data F1  Assembly and installation advice Installation and operation of this device is only allowed to be executed by a qualified electrician! The application has to be separated from any power during the mounting process. Wires have to be connected safely and must not have contact with sharp edges. Pay attention to correct polarity! Before commissioning, check all the connections for correctness! metal chassis bottom Using the provided gap pad the DC300WS has to be mounted in a metal case via the bottomside of the board. In order to cool the power supply, a heat-absorbing...

Open the catalog to page 14
DC300WS - 15

F3 Anschlussbeschreibung F3 Anschlussbeschreibung F3  Description of connectors F3 Anschlussbeschreibung + + Sense Sense Sense - Sense Sense Sense + TYPE Kennung FUNCTION J1 J2 VDC output Plus (+) (-) VDC Ausgang Minus J1 Kennung Funktion Kennung Funktion J3 Konfiguration Ausgangsspannung J1 J2 VDC Ausgangoutput Minus (–) Plus (+) Anschluss VDC Ausgang Plus (+) J1 J4 VDC Ausgang-Sense J2 VDC Ausgang Minus (-) Konfiguration J5 Remote Ein / Aus J2 VDC Ausgang Minus (-) J6 Configuration Aus Anschluss Remote Ein / output voltage J3 J3 Konfiguration Ausgangsspannung J3 Konfiguration...

Open the catalog to page 15

All Bicker Elektronik GmbH catalogs and technical brochures

  1. UPS-1000-B1

    32 Pages

  2. BE-DCEB5A

    2 Pages

  3. BE-DCEB10A

    2 Pages

  4. BP-LFP-13250S

    18 Pages

  5. BP-LFP-10250S

    18 Pages

  6. BP-LFP-1325S

    19 Pages

  7. BP-LFP-1025S

    19 Pages

  8. DC2412-UPSP2

    9 Pages

  9. BP-LFP-2725D

    22 Pages

  10. BP-LFP-2725

    22 Pages

  11. BP-LFP-1375D

    5 Pages

  12. BP-LFP-1375

    5 Pages

  13. UPSI-2412DP2

    31 Pages

  14. UPSI-2412D

    31 Pages

  15. UPSI-2406

    3 Pages

  16. UPSI-2412

    31 Pages

  17. DC161W

    5 Pages

  18. BEP-520C

    4 Pages

  19. IUPS-401

    3 Pages

  20. DC2412-UPS

    6 Pages

  21. UPSIC-2403

    5 Pages

  22. UPSIC-1205

    5 Pages

  23. UPSI-1208DP2

    27 Pages

  24. UPSI-2406DP2

    27 Pages

  25. UPSI-2406DP1

    27 Pages

  26. UPSI-2406D

    3 Pages

  27. UPSI-1208

    3 Pages

  28. BES-540T

    2 Pages

  29. BES-540C

    2 Pages

  30. BEH-542C

    3 Pages

  31. BEA-750H

    4 Pages

  32. BEA-550K

    4 Pages

  33. BEA-630

    2 Pages

  34. BEP-530H

    3 Pages

  35. BEP-520H

    3 Pages

  36. BEP-510

    3 Pages

  37. DC160WS

    5 Pages

  38. DC160W

    4 Pages

  39. DC1224

    2 Pages