Long-life battery pack High reliability Safe lithium iron phosphate technology 100 % free of lead and cadmium Extended temperature range High performance BMS system Advanced charging algorithms and cell balancing Battery relax mode for lifetime extension Integrated protection against deep discharge, over current, over voltage and short circuit Compact shrink tube version UN 38.3 transportation certification Te c h n i c a l d a t a Nominal capacitance Technology Life cycles Temperature Communication 7500 mAh LiFePO4 (Lithium iron phosphate) > 6000 Operating: -20…+55 °C / Storage: -30…+55 °C SMB Product specific data Nominal voltage Number of used cells Charge voltage Charge current Discharge current Dimensions (Wx D x H) Operating: 10…90 % RH, non-condensing Storage: 10…80 % RH, non-condensing Nominal backup time, measured at +21 °C 50 W BP-LFP-1375 ~ 99 min Back up time depends on battery capacitance, load and temperature. At very high or low temperatures a reduction of backup time occurs. Bicker Elektronik GmbH | 86609 Donauwörth |
Open the catalog to page 1UPS systems Optional Accessories detailed information please visit our website www.bicker.de and refer to the article number. For PSZ-1075 | Mounting bracket Mounting bracket for BP-LFP-1099/1375, 2-pices set SMBC SMBD SYSPRES SGND Tolerance: Cable: ±5mm / Battery pack: ±2mm Bicker Elektronik GmbH | 86609 Donauwörth | Germany Tel. +49 906 70595-0 | [email protected]
Open the catalog to page 2UPS systems Backup time BP-LFP-1375 nominal backupNominal over output PPower, calculated, 21°C time backup time vs. (calculated @ 21°C) out DC UPS Bicker Elektronik GmbH | 86609 Donauwörth | Germany Tel. +49 906 70595-0 | [email protected] | www
Open the catalog to page 3UPS systems BP-LFP – LiFePO4 cell specifications SPECIFICATION Nominal Voltage Nominal Capacity Maximum discharge current - continuous (A) Recommended standard charge Recommended fast charge Recommended float charge voltage Recommended end of discharge cutoff Absolute maximum cell temperature 85 ° C (measured at cell surface) Nanophosphate® Chemistry Current Interrupt Device (CID) BP-LFP – Battery voltage and current during recharge VoltageCurrent Voltage & & Current Charger holds output to a steady „float“ voltage Battery Voltage Charger holds a steady constant current output Battery Current...
Open the catalog to page 4UPS systems BP-LFP – Cycle life at various temperatures Capacity fade (% of BOL capacity) 100 % Cell Type: 2.5 Ah cylindrical Cell cycles / year: 363 kWh / year: 2.72 SOCavg: 57.5 % Cycle number BP-LFP – Calendar life at various temperatures Capacity fade (% of BOL capacity) Specification is subject to change without notice. Errors excepted. Status as at: 08.07.2021 Time (year) Bicker Elektronik GmbH | 86609 Donauwörth | Germany Tel. +49 906 70595-0 | info@bicker
Open the catalog to page 520 Pages
45 Pages
45 Pages
31 Pages
31 Pages
31 Pages
31 Pages
38 Pages
38 Pages
32 Pages
2 Pages
2 Pages
18 Pages
18 Pages
19 Pages
19 Pages
9 Pages
31 Pages
22 Pages
22 Pages
5 Pages
4 Pages
31 Pages
3 Pages
31 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
5 Pages
5 Pages
4 Pages
4 Pages
4 Pages
3 Pages
3 Pages
3 Pages
6 Pages
3 Pages
3 Pages
9 Pages
4 Pages
3 Pages
6 Pages
5 Pages
5 Pages
27 Pages
3 Pages
3 Pages
2 Pages
2 Pages
3 Pages
4 Pages
4 Pages
2 Pages
3 Pages
3 Pages
3 Pages
4 Pages
5 Pages
4 Pages
4 Pages
2 Pages