Medical applications 200W continuous fanless power High power density Very compact design High efficiency up to 93.5% Meet Class I and Class II (without FG) +12 V fan output Low Standby consumption: <0.3 W Wide temperature range -20…+80 °C Extended Delivery Medical Delivery Fanless Medical Also available as open frame Art. No. BEO-2000M Input voltage Input frequency Input current Inrush current Efficiency Standby consumption Hold up time Protection Insulation voltage Insulation resistance Line regulation Load regulation Earth leakage current Touch current* Safety/EMC Temperature Derating Max. operation altitude MTBF Humidity Dimension (W x Dx H) Weight (net) 90…264 V AC (100…240 V AC nominal), active PFC 47…63 Hz (50…60 Hz nominal) <1 A (240 V AC) <100 A (240 V AC) 92…93.5 % depending on model (230 V AC) <0.3 W 10 ms (115 V AC) Short circuit protection: Hiccup mode (auto recovery) Overtemperature protection Overvoltage protection: switch off (recycle AC input to restart) Input / Output 6196 V DC (2 x MOPP) Output / FG 2122 V DC (1 x MOPP) Input / FG 2122 V DC (1 x MOPP) Input / Output min. 100 MΩ (500 V DC test voltage) ±0.5 % ±1 % <310 µA (264 VAC / 60 Hz) <70 µA (264 VAC / 60 Hz) IEC 60601-1:2005+A1:2012 (Edition 3.1) EN 60601-1:2006+A1:2013 (Edition 3.1) ANSI/AAMI ES60601-1:2005 (3rd Edition), CE Operating: -20…+80 °C / Storage: -40…+85 °C See diagram 3000 m >279 000 h according to MIL-HDBK-217F at +25 °C / 115 V AC Operating: 10…85 % RH, non-condensing / Storage: 10…90 % RH, non-condensing 117 x 62 x 40 mm ±1 mm 0.32 kg *For class I construction with PE connection Bicker Elektronik GmbH | 86609 Donauwörth | Germany Tel.
Open the catalog to page 1* 200W continuous fanless with minimum input voltage 100VAC (see derating diagrams). Ripple and noise was measured by a 20MHz bandwidth limited oscilloscope with connected 0dpF and 10pF capacitors at the output. As a power component this PSU is for assembly purposes only and must not be operated in unassembled condition. The final assembly has to comply with the valid EMC and safety standards. [>[>[> For detailed information please visit our website www.bicker.de and refer to the article number. X1-054 | AC input cable 2-pole, length 600 mm, AWG18, ends open Power supplies With natural convection...
Open the catalog to page 2Bicker Elektronik GmbH | 86609 Donauwörth | Germany Tel. +49 906 70595-0 | [email protected] | www.bicker.de Power supp
Open the catalog to page 3Medical applications Drawing BEO-2000MC Tolerance ±1 mm Power supplies Input connector (CN1): VHR-3N or similar Output connector: Screw terminal M3 Specification is subject to change without notice. Errors excepted. Status as at: 29.05.2018 Also available as open frame Mounting recommendation: To ensure best heat dissipation, it is recommended to mount the BEO-2000MC directly on metal chassis. Art. No. BEO-2000M Bicker Elektronik GmbH | 86609 Donauwörth | Germany Tel. +49 906 70595-0 | [email protected] | ww
Open the catalog to page 420 Pages
45 Pages
45 Pages
31 Pages
31 Pages
31 Pages
31 Pages
38 Pages
38 Pages
32 Pages
2 Pages
2 Pages
18 Pages
18 Pages
19 Pages
19 Pages
9 Pages
31 Pages
22 Pages
22 Pages
5 Pages
5 Pages
4 Pages
31 Pages
3 Pages
31 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
5 Pages
5 Pages
4 Pages
4 Pages
3 Pages
3 Pages
3 Pages
6 Pages
3 Pages
3 Pages
9 Pages
4 Pages
3 Pages
6 Pages
5 Pages
5 Pages
27 Pages
3 Pages
3 Pages
2 Pages
2 Pages
3 Pages
4 Pages
4 Pages
2 Pages
3 Pages
3 Pages
3 Pages
4 Pages
5 Pages
4 Pages
4 Pages
2 Pages