Medical applications © 140 W continuous fanless power on 2 x 4" © 200 W power with forced air cooling © Very compact design © Efficiency up to 93 % © Wide temperature range -20...+70 °C © Operating altitude 5000 m © Safety approved to IEC/EN/UL62368-1/60601-1 (Ed. 3.1) © Means of protection (2x MOPP) Technical data Input voltage Input frequency Input current Inrush current Efficiency Standby consumption Hold up time Protection Insulation voltage Load regulation Leakage current Safety / EMC Temperature Derating MTBF Max. operating altitude Humidity Dimensions (Wx D x H) Weight (net) 90.. .264 VAC (100.. .240 V AC nominal), active PFC 47.. .63 Hz (50.60 Hz nominal) <2 A (115 V AC), <1 A (230 VAC) 120 A max (cold start at +25 °C) 92 % typical <0.21 W >20 ms (full load) Short-circuit protection Overcurrent protection Overtemperature protection Overvoltage protection 4 kVac (Primary to Secondary), 1.5 kVac (Primary to Frame Ground) ±3 % <0.1 mA IEC/EN/UL62368-1, EN55032: Class B, IEC/UL60601-1, IEC/EN/UL6060-1-2, IEC60601-1-2:2014 (Ed. 4.0) Operating: -20.. .+70 °C / Storage: -20.. .+85 °C See diagram 300 000 h according to Telcordia SR-332 5000 m Operating: 20.80 % RH, non-condensing / Storage: 10.90 % RH, non-condensing 50.8 x 101.6 x 32 mm ±1 mm 0.210 kg Power supplies Article No. * 140 W max. fanless *2 200 W max. with 12 CFM fan Ripple and noise was measured by a 20MHz bandwidth limited oscilloscope with connected 1pF and 10pF capacitors at the output. As a power component this PSU is for assembly purposes only and must not be operated in unassembled condition. The final assembly has to comply with the valid EMC and safety standards. Note: The device has to be mounted on a metal plate! Bicker Elektronik GmbH | 86609 Donauworth | Germany Tel. +49 906 70595-0 | [email protected] | www.bicker.de
Open the catalog to page 1Medical applications Optional Accessories detailed information please visit our website www.bicker.de and refer to the article number. For X1-054 | AC input cable 2-pole, length 600 mm, AWG18, ends open 3-pole, length 600 mm, AWG18, ends open 4-pole, length 600 mm, AWG 18, ends open Power supplies Start at temperatures below 0 °C can cause higher ripple Bicker Elektronik GmbH | 86609 Donauwörth | Germany Tel. +49 906 70595-0 | info@bick
Open the catalog to page 2Bicker Elektronik GmbH | 86609 Donauworth | Germany Tel. +49 906 70595-0 | [email protected] | www.bicker.de
Open the catalog to page 3Power supplies NOTE: The device has to be mounted on a metal plate! CAUTION: Please remove foil from gap pad before mounting! Bicker Elektronik GmbH | 86609 Donauworth | Germany Tel. +49 906 70595-0 | [email protected] | www.bicker.de
Open the catalog to page 4Power supplies Specification is subject to change without notice. Errors excepted. Status as at: 06.07.2020 Scope of delivery Quantity Description Bicker Elektronik GmbH | 86609 Donauworth | Germany Tel. +49 906 70595-0 | [email protected] | www.bicker.de
Open the catalog to page 520 Pages
45 Pages
45 Pages
31 Pages
31 Pages
31 Pages
31 Pages
38 Pages
38 Pages
32 Pages
2 Pages
2 Pages
18 Pages
18 Pages
19 Pages
19 Pages
9 Pages
31 Pages
22 Pages
22 Pages
5 Pages
5 Pages
4 Pages
31 Pages
3 Pages
31 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
5 Pages
4 Pages
4 Pages
4 Pages
3 Pages
3 Pages
3 Pages
6 Pages
3 Pages
3 Pages
9 Pages
4 Pages
3 Pages
6 Pages
5 Pages
5 Pages
27 Pages
3 Pages
3 Pages
2 Pages
2 Pages
3 Pages
4 Pages
4 Pages
2 Pages
3 Pages
3 Pages
3 Pages
4 Pages
5 Pages
4 Pages
4 Pages
2 Pages