Air Atomizing
16Pages

{{requestButtons}}

Catalog excerpts

Air Atomizing - 1

J PL Series Air Atomizing Nozzles SPRAY NOZZLES

Open the catalog to page 1
Air Atomizing - 2

JPL Series Air Atomizing Spray Nozzles BEX JPL Air Atomizing Spray Nozzles use compressed air (or gas) to produce an accurately controlled liquid dispersion in applications where a conventional liquid spray nozzle would not be suitable. Typical applications include humidification, cooling, air pollution control, coating processes, lubrication, curing, chemical dispersion, and many other uses. The JPL Series are excellent products for new applications, and are suitable for replacing products in existing atomizing applications. Many of the JPL Series components are interchangeable with...

Open the catalog to page 2
Air Atomizing - 3

AIR ATOMIZING NOZZLE TABLE OF CONTENTS What is a Standard JPL Assembly? . . . . . . . . . . . . . . . page 1 How to Select a Set-up . . . . . . . . . . . . . . . . . . . . . . . . . page 2 Choices of Spray Set-ups and Basic Nozzle Installations . . . . . . . . . . . . . . . . . . . . page 3 Internal Mix Set-ups Round Spray Pattern . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 4 Wide-Angle Spray Pattern . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5 Flat Spray Pattern . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5...

Open the catalog to page 3
Air Atomizing - 4

HOW TO SELECT A SET-UP All BEX “JPL” Series products are designed to provide a wide range of performance flexibility, allowing the user to adjust the liquid and air feed to the setup. By adjusting the liquid and/or air source, a variety of spray droplets and atomiza- tion can be obtained. The performance tables that follow provide spray capacities at certain liquid/air flow combinations for water under standard conditions. These are not by any means the only possible results for each specific set-up. QUICK REFERENCE If you know how much liquid flow you desire from the nozzle, but are unsure...

Open the catalog to page 4
Air Atomizing - 5

CHOICE OF SPRAY SET-UPS Each spray set-up consists of an air cap and liquid cap which provide a specific spray pattern, capacity and coverage performance. The set-up will produce com- parable spray performance with any of the various bodies available. INTERNAL MIX Liquid and gas are mixed internally to produce a completely atomized spray. Available in Round, Wide-Angle Round and Flat Spray patterns. Common uses: Dust control, pesticide application, humidification, cooling, coating and low viscosity fluids. EXTERNAL MIX Liquid atomization is controlled by varying the air pressure without...

Open the catalog to page 5
Air Atomizing - 6

BEX JPE series round spray Pressure feed - Internal mix APPLICATION AND PERFORMANCE Set-ups with BEX JPG series air caps produce a round spray pattern. The liquid is pressure fed and internally mixed. Nozzle selection is not limited for other parameters. optimum pattern spray pattern See page 12 and 13 for instructions on how to order. JPE Round Spray Performance Chart LIQUID CAPACITY in GPH and AIR CAPACITY in SCFM BEX Set-up No. Spray Set-up Consists of Liquid and Air Cap Combination SPRAY DIMENSIONS Optimum MaxiPattern mum “— —” means not recommended at this pressure Note: All references...

Open the catalog to page 6
Air Atomizing - 7

BEX JPG series wide-angle round spray Pressure feed - Internal mix APPLICATION AND PERFORMANCE Set-ups with BEX JPE series air caps produce a wide-angle round spray pattern. The liquid is pressure fed and internally mixed. Nozzle selection is not limited for other parameters. 6" 9" spray pattern 15" See page 12 and 13 for instructions on how to order. JPG Wide-Angle Round Spray Performance Chart BEX Set-up No. Spray Set-up Consists of Liquid and Air Cap Combination LIQUID CAPACITY in GPH and AIR CAPACITY in SCFM LIQUID PRESSURE in psi 20 psi 30 psi 40 psi “— —” means not recommended at this...

Open the catalog to page 7
Air Atomizing - 8

BEX JPD series flat spray Pressure feed - Internal mix APPLICATION AND PERFORMANCE Set-ups with BEX JPD series air caps produce a flat spray pattern. The liquid is pressure fed and internally mixed. Nozzle selection is not limited for other parameters. 6" 9" spray pattern See page 12 and 13 for instructions on how to order. JPD Flat Spray Performance Chart BEX Set-up No. Spray Set-up Consists of Liquid and Air Cap Combination LIQUID CAPACITY in GPH and AIR CAPACITY in SCFM LIQUID PRESSURE in psi 20 psi 30 psi 40 psi SPRAY DIMENSIONS Pattern MaxiWidth in Inches mum “— —” means not...

Open the catalog to page 8
Air Atomizing - 9

BEX JPV series round & JPK series flat spray Siphon/Gravity feed APPLICATION AND PERFORMANCE Set-ups with BEX JPV and JPK series air caps produce round and flat spray patterns respectively. The liquid is gravity or siphon fed into the airstream. Nozzle selection is not limited for other parameters. If you do not find the product for your application, please contact BEX. optimum pattern spray pattern See page 3 for siphon and gravity feed installation. See page 12 and 13 for instructions on how to order. JPV Round Spray Performance Chart ATOMIZING AIR BEX Set-up No. Spray Set-up Consists of...

Open the catalog to page 9
Air Atomizing - 10

BEX JPT series flat spray Pressure feed - External mix APPLICATION AND PERFORMANCE BEX JPT series air caps produce a flat spray pattern. Liquid is pressure fed and externally mixed. Nozzle selection is not limited for other parameters. If you do not find the product for your application range, please contact BEX. spray pattern See page 12 and 13 for instructions on how to order. JPT Flat Spray Performance Chart BEX Set-up No. Spray Set-up Consists of Liquid and Air Cap Combination LIQUID CAPACITY in GPH and AIR CAPACITY in SCFM LIQUID PRESSURE in psi 5 psi 10 psi 20 psi SPRAY DIMENSIONS...

Open the catalog to page 10
Air Atomizing - 11

JPT Flat Spray Performance Chart (continued) BEX Set-up No. Spray Set-up Consists of Liquid and Air Cap Combination LIQUID CAPACITY in GPH and AIR CAPACITY in SCFM LIQUID PRESSURE in psi 5 psi 10 psi 20 psi SPRAY DIMENSIONS Optimum Pattern MaxiWidth in Inches mum “— —” means not recommended at this pressure Spray Range feet Note: All references to GPH are U.S. gallons per hour

Open the catalog to page 11
Air Atomizing - 12

Alternative Bodies (Connections) and Mounting For specific application details, please contact BEX. TOP-CONNECT BODY 2JTPL - 1/4" Top-Connect JPL Body Air (gas) and liquid inlets are both on top of this body, 90° from the nozzle outlet. BACK-CONNECT BODY 2JBPL - 1/4" Back-Connect JPL Body Air (gas) and liquid inlets are on back of this body, 180° from the nozzle outlet. THICK WALL MOUNT JPLM Wall adapter replaces the cap retaining ring with a 3/4” MNPT adapter which allows mounting any JPL assembly to a thick wall (over 3/8” thick). THIN WALL MOUNT JPLN Thin wall adaptation, simply add a...

Open the catalog to page 12

All BEX catalogs and technical brochures

  1. Catalog

    100 Pages

  2. catalog 56